background image

Single Pole (One location) or 3-Way (Multi-location)

Magnetic Low-Voltage Dimmer

Cat. No. TGM1Ø-1L (Lighted)

1000VA–120VAC, 60Hz

INSTALLATION INSTRUCTIONS

DI-000-TGM10-02A

Tools needed to install your Dimmer:

Slotted/Phillips Screwdriver

Electrical Tape

Pliers

Pencil

Cutters

Ruler

Installing Dimmer by itself or with other devices:

If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR  DIMMER section. If installing Dimmer in a multi-
device application, proceed as follows:

MULTI-DEVICE APPLICATION

NOTE: You only need to remove side sections if installing with other
dimmers or if it does not fit in wall box – not when installing with
mechanical switches.

When installing more than one dimmer, the side sections of the
mounting strap must be removed. Use pliers to carefully bend side
sections back and forth until they break off. The side sections
dissipate heat, so removing them requires a derating of the dimmer's
capacity (see chart).

MAXIMUM BULB WATTAGE

Low-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb
wattage is determined by the efficiency of the transformer in the low-
voltage lighting system. Transformer efficiencies will vary from
different manufacturers; consider 75% efficient as an example. Use
the chart to determine maximum bulb wattage for typical transformer
efficiency ratings.

INSTALLING YOUR DIMMER

NOTE: Use check boxes       when Steps are completed.

WARNING:

 To avoid fire, shock, or death; TURN OFF

POWER at circuit breaker or fuse and test that power is off
before wiring!

Removing existing switch:

 Remove existing

wallplate and switch mounting screws. Carefully pull switch
from wall box. DO NOT remove wires attached to the switch
at this time.

Identifying your wiring application (most
common):

NOTE: If the wiring in the wall box does not resemble any of
these configurations, consult a qualified electrician.

Step 2

Preparing and connecting wires:

Step 4

Single-Pole Wiring Application:

Step 1

Step 3

WARNINGS & CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to

control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance.

• Use with magnetic low-voltage transformers, incandescent, or 120V halogen fixtures only. Use a

Leviton electronic low-voltage dimmer to control electronic (solid state) low-voltage transformers.

• Total minimum wattage must exceed 40VA.

WARNINGS & CAUTIONS:

• When magnetic low-voltage circuits are operated at a dim level, with all lamps inoperative, excess

current may flow through the transformer. To avoid possible transformer failure due to overcurrent, use
a transformer that incorporates thermal protection or a fuse at the primary windings.

• Use only one (1) dimmer in a 3- or 4-way circuit. The switch(es) will turn the light on at the brightness

level selected at the dimmer.

• Disconnect power at circuit breaker or fuse when servicing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked

CO/ALR or CU/AL.

• Recommended to use with non-metallic wallplates.

Bend back and
forth to remove side
section

Remove
all inner
side
sections

Do not
remove
outer
side
sections

Step 5a

Insert wires

straight then twist

clockwise

Electrical

Tape

More than

 Cat. No.

 Single

Two Devices

2 Devices

TGM1Ø-1L

 1000VA

    800VA

700VA

MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE

           

 Two

  More than

            Rating               Single      Gang

  

  2 Gang

            1000VA               750W

 600W

  525W

MAXIMUM BULB WATTAGE AT 75% EFFICIENCY

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

2

4

3

1

2

4

1

5

3

3-Way

1. Line or Load

 (See important

instruction below)

2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color

Single-Pole

1. Line (Hot)
2. Neutral
3. Ground
4. Load

IMPORTANT: For 3-Way applications, note that one of the screw
terminals from the old switch being removed will usually be a different
color (Black) or labeled Common. Tag that wire with electrical tape and
identify as the common (Line or Load) in both the dimmer wall box and
3-way wall box.

Step 3 cont'd

Make sure that the ends of the wires from the wall box are
straight (cut if necessary).

Remove 5/8" (1.6 cm) of insulation from each wire in the wall box
(shown).

For Single-Pole Application, go to Step 5a.

For 3-Way Application, go to Step 5b.

Cut

(if necessary)

Strip Gage

(measure bare wire here)

5/8"

(1.6 cm)

Black

Red

Neutral

Green

Ground

Red

This wire is used in 3-way installations only.
For single pole installations, do not remove this
insulating label.

4

3

1

2

Reviews: