background image

Single Pole (One location) or 3-Way (Multi-location)

Incandescent Dimmer

Cat. No. VZIØ6-1L, 600W (Lighted) 

120VAC, 60Hz

INSTALLATION INSTRUCTIONS

DI-000-VZI06-02C

Preparing and connecting wires:

This dimmer can be wired using side wire terminal 

screws or through backwire openings. Choose 

appropriate wire stripping specifications accordingly.

WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:

  Green or bare copper wire in wall box to Green terminal screw.

• 

Line Hot wall box wire to terminal screw marked “BK”.

• 

Load wall box wire to terminal screw marked “RD”.

•   

Dimmer terminal screw marked “YL/RD” should have Red 

insulation label affixed.

NOTE: 

If insulating label is not affixed to terminal screw marked 

“YL/RD”, use electrical tape to cover.

•  Proceed to Step 5.

hot (Black)

Neutral (White)

Load

Dimmer

Bk

Black

White

RD

Green

Ground

Line 

120VAC, 60hz

yL/RD

Use Terminal for 3-Way or

More Applications Only.

For Single-Pole Applications,

Do Not Remove This Label.

•   Make sure that the ends of the wires from the wall box are 

straight (cut if necessary)

.

•  Remove insulation from each wire in the wall box as shown.
• 

For Single-Pole Application, go to Step 4a.

•   

For 3-Way Coordinating Remote (no LEDs) Application, go to 

Step 4b.

•   

For 3-Way Matching Remote (with LEDs) Application, go to 

Step 4c.

WARNINGS AND CAUTIONS:

•  To be installed and/or used in accordance with appropriate electrical codes and regulations.
•  If you are unsure about any part of these instructions, consult a qualified electrician.
•   To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-

operated appliance.

•  Use with incandescent or 120V halogen fixtures only.
•  Vizia™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ remotes for multi-location dimming.
•  Use only one (1) Vizia™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will 

turn the light on at the brightness level selected at the dimmer.

WARNINGS AND CAUTIONS:

•  Dimmer may not operate with dioded lamps (Sylvania Designer 16™ or Philips PAR-16™).
•  Total minimum load must exceed 40W.
•  Dimmer may feel warm to the touch during normal operation.
•  Recommended minimum wall box depth is 2-1/2”.
•  Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
•  Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
•  Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.

 Step 4a cont’d

IMPORTANT:

 For 3-Way applications, note that one of the screw 

terminals from the old switch being removed will usually be a 

different color (Black) or labeled Common. Tag that wire with 

electrical tape and identify as the common (Line or Load) in both the 

dimmer wall box and remote wall box.

Strip Gage 

(measure bare wire 

here or use gage on 

back of the dimmer)

5/8”

(1.6 cm)

Cut

(if necessary)

Bl

Back Wire 

(either hole may be used)

Back wire openings use #14-12 

AWG solid copper wire only.

Side Wire Connection

Side wire terminals accept #14 

AWG solid copper wire only.

WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:

NOTE:

 When using the coordinating remote without LEDs, the dimmer 

can be installed on either the Line or Load side of the 3-way circuit.

NOTE: 

Maximum wire length from dimmer to all installed remotes 

cannot exceed 300 ft.

  Green or bare copper wire in wall box to Green terminal screw.

•   

Line Hot (common) wall box wire identified (tagged) when removing 

old switch to terminal screw marked “BK”.

•   

First Traveler wall box wire to terminal screw marked “RD” 

(note 

wire color)

. This traveler from the dimmer must go to the terminal 

screw on the remote marked “RD”.

•   

Remove Red insulating label from terminal screw marked “YL/RD”.

•   

Second Traveler wall box wire to terminal screw marked “YL/RD” 

(note wire color)

. This traveler from the dimmer must go to the 

terminal screw on the remote marked “YL/RD”.

WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:

NOTE: 

Maximum wire length from dimmer to last remote is 300ft.

  Green or bare copper wire in wall box to Green terminal screw.

•   

Load wall box wire identified (tagged) when removing old switch to 

terminal screw marked “BK”.

•   

First Traveler wall box wire 

(note color as above)

 to terminal 

screw marked “RD”. This traveler from the remote must go to the 

terminal screw on the dimmer marked “RD”.

•   

Second Traveler wall box wire 

(note color as above)

 to terminal 

screw marked “YL/RD”. This traveler from the remote must go to 

the terminal screw on the dimmer marked “YL/RD”.

•   

Remote terminal screw marked “WH” should have White insulation 

label affixed.

NOTE: 

If insulating label is not affixed to terminal screw marked 

“WH”, use electrical tape to cover.

•  Proceed to Step 5.

hot (Black)

Neutral (White)

Load

Dimmer

Coordinating Remote (no LEDs)

yL/RD

yL/RD

RD

Wh

RD

Bk

Bk

Black

Do not use for

incandescent

applications.

White

Line 

120VAC, 60hz

Green

Ground

Green

Ground

Push in side 

at tab to release

Line up tabs and 

press in side to attach

MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE

 Tools needed to install your Dimmer

 Installing Dimmer by itself or with other devices

Slotted/Phillips Screwdriver 

Electrical Tape 

Pliers 

Pencil 

 

 

Cutters 

 

Ruler

Changing the color of your Dimmer:

If a color change kit is provided with your device and a color change 

is desired, proceed with the following step. Otherwise, proceed to 

“Installing Dimmer by itself or with other devices” section. To change 

color of your device proceed as follows:

If installing Dimmer in a single device application, proceed with the 

INSTALLING yOUR DIMMER

 section. If installing Dimmer in a 

multi-device application, proceed as follows:

MULTI-DEVICE APPLICATION:

In multi-dimmer installations, the reduction of the dimmer’s capacity 

is required. Refer to the chart for maximum load per dimmer.

Cat. No.

VZIØ6

Single

600W

Two Devices

500W

More than 2 

Devices

400W

INSTALLING yOUR DIMMER

NOTE: 

Use check boxes        when Steps are completed.

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

 Step 1

WARNING:

 

TO AVOID FIRE, ShOCk, OR DEATh; 

TURN OFF POWER

 at circuit breaker or fuse and test 

that power is off before wiring!

2

4

1

5

3

3-Way

1.   

Line or Load

 (See important 

instruction below)

2. 

Neutral

3. 

Ground

4. 

First Traveler – note color

5. 

Second Traveler – note color

NOTE:

 For matching remote w/LEDs 

installation, the 

First

 

Traveler

 becomes 

Line Hot.

2

4

3

1

Single-Pole

1. 

Line (Hot)

2. 

Neutral

3. 

Ground

4. 

Load

 Step 2

Identifying your wiring application (most 

common):

NOTE:

 If the wiring in the wall box does not resemble any 

of these configurations, consult a qualified electrician.

 Step 3

Bk

yL/RD RD

Terminal

Screw marked

Black (Bk)

Terminal

Screw marked

Red (RD)

Terminal

Screw marked

yellow/Red

(yL/RD)

Terminal Label:

Use Terminal for 3-Way or More Applications Only.

For Single-Pole Applications, Do Not Remove This

Label.

4

3

2

1

Single-Pole Wiring Application:

 Step 4a

Bk

yL/RD RD

Bk

yL/RD RD

4

3

2

1

5

Terminal

Screw marked

Black (Bk)

Terminal

Screw marked

Red (RD)

Terminal

Screw marked

yellow/Red

(yL/RD)

Coordinating Remote

2

4

3

5

1

Dimmer

(Coordinating Dimming Remote Depicted)

3-Way Wiring with Coordinating 

Dimming or Switching Remote (no LEDs) 

Application:

 Step 4b

 Step 4b cont’d

Reviews: