4300 Dual-Handed Swingbolt or 6040-DB Deadbolt Lock Instructions

MANAGER PROGRAMMING

CHANGING YOUR CODE 

(Without 

eKEY or eKEY

II

)

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

If your unit is programmed for Dual Code, each code must be
changed independently.

Enter existing code and hold down the last digit until unit
double signals twice and the LED stays on.

Press the “0” key.

Enter your NEW six (6) digit code two times.

If a mistake is made wait thirty (30) seconds and repeat steps 

1

3

.

Test unit operation several times before closing the door.

•  Valid Code Entry

- Double signal after valid six (6) digit code is

entered.

•  Invalid Code Entry

- Triple signal and old code is still valid.

MANAGER CODE MUST BE CHANGED PRIOR TO
PERFORMING ANY ACTION OTHER THAN OPENING THE
LOCK

OPENING THE LOCK

(Without 

eKEY or eKEY

II

)

Enter valid six (6) digit code.

The unit will indicate a valid code entry with a double signal.

Within four (4) seconds open lock by either rotating the keypad
to open position (Clock-wise) or turning the handle to the open
position.

Pull door open.

•  Invalid Code Entry

- Unit will signal three (3) times.

Suggested Keypad

ACTIVATING USER

(Manager Only, without eKEY or eKEY

II

)

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

Enter Manager code and hold down last digit of code until unit
double signals twice and the LED stays on.

PRESS 1. Unit signals twice.

Press User number, 2 to 9. Unit signals twice.

Enter NEW six (6) digit User code two times.

If a mistake is made wait thirty (30) seconds and repeat steps

1

4

.

•  Valid Code Entry

- Double signal after valid six (6) digit code is

entered.

•  Invalid Code Entry

- Triple signal and old code is still valid.

DISABLE USER 

(Manager Only, without eKEY or eKEY

II

)

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

Enter Manager code and hold down last digit of code until unit
double signals twice and the LED stays on.

PRESS 2. Unit signals twice.

Press User number, 2 to 9. Unit signals once.

User is temporarily disabled.

If a mistake is made wait thirty (30) seconds and repeat steps

1

3

.

•  Valid Code Entry

- Double signal after valid six (6) digit code is

entered.

•  Invalid Code Entry

- Triple signal and old code is still valid.

STANDARD FEATURES
MANAGER CODE

(Factory set to 1-2-3-4-5-6 or 7-8-9

depending on code length)

•  Activate/Delete Users
•  Enable/Disable Users
•  Set Time Delay Values
•  Open Lock

USER CODE

•  Open Lock
•  Change Code

TIME DELAY

•  Delay period 1 - 99 minutes
•  Open period 1 - 19 minutes

DUAL CODE

•  Two codes required to open

SIGNAL TO DISABLE LOCK OPENING 

(Optional Alarm Box

Required)

•  Input signal disables opening of lock by valid code

WRONG TRY PENALTY

•  Four (4) consecutive invalid codes initiates five minute

delay period.

LOW BATTERY WARNING

•  Repeated audio and visual signal (LED flashing and

repeated beeping) during opening indicates battery low.

AUDIO AND VISUAL SIGNAL

•  Double signal (LED flashes and unit beeps) indicates

entry is valid or accepted.

•  Triple signal indicates invalid or not accepted.

AUDIT TRAIL

•  For audit features see LPAUDIT Software Package

3750-K

Round Entry

PC PROGRAMMABLE FEATURES
MULTIPLE USERS

Up to nine (1 Manager and 8 Users)
User # Installed   2     3     4    5     6    7     8     9

ACTIVE

CODE LENGTH

TIME DELAY OVERRIDE

•  Ability to add second combination to override delay

period

SILENT SIGNAL ALARM 

(Optional Alarm Box Required)

•  Duress signal if last number of code(s) is entered using

one number higher or one number lower.

SIGNAL TO  DISABLE LOCK 

(Optional Alarm Box Required)

•  Input signal disables all lock functions by valid code

eKEY

or 

e

KEY

II

•  Use of key and code required

Lock Choices

4300

Dual-Handed Swingbolt

6040-DB
Deadbolt

•  

All locks are shipped from the factory in Pre Set-up
mode, with no features installed.

•  

Lock will open when 1 is pressed.

•  

Please follow LPAUDIT PC software instructions to
initially configure locks to default settings.

4300 is a new part

number replacing the

6260

3125 Round

Entry

Summary of Contents for 4300

Page 1: ...last digit of code until unit double signals twice and the LED stays on 2 PRESS 2 Unit signals twice 3 Press User number 2 to 9 Unit signals once 4 User is temporarily disabled 5 If a mistake is made wait thirty 30 seconds and repeat steps 1 3 Valid Code Entry Double signal after valid six 6 digit code is entered Invalid Code Entry Triple signal and old code is still valid STANDARD FEATURES MANAGE...

Page 2: ...9 cannot be disabled or removed Entry of Override code during Delay period will open the lock SILENT SIGNAL ALARM If feature is active AND optional Alarm Box is connected to an alarm system Without eKEY or eKEYII Enter last digit of code one number higher or one number lower Example Code 1 2 3 4 5 6 Duress 1 2 3 4 5 5 or 1 2 3 4 5 7 The lock will open without any indication that the duress signal ...

Page 3: ...I ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN 1 Enter Manager code and hold in key until unit double signals twice and the LED stays on 2 PRESS 2 Unit signals twice 3 Press User number 2 to 9 Unit signals once 4 User is temporarily disabled 5 If a mistake is made wait thirty 30 seconds and repeat steps 1 3 Valid Code Entry Double signal after valid six 6 digit code is entered Invalid Code Ent...

Page 4: ... deleted If the User is disabled or deleted this feature will no longer function Entry of Override code during Delay period will open the lock SILENT SIGNAL ALARM If feature is active AND optional Alarm Box is connected to an alarm system Enter last digit of code one number higher or one number lower Example Code 1 2 3 4 5 6 Duress 1 2 3 4 5 5 or 1 2 3 4 5 7 The lock will open without any indicati...

Reviews: