© copyright 2006
12-239v3
LA GARD INC - A Member of The Kaba Group
4300 Dual-Handed Swingbolt or 6040-DB Deadbolt Lock Instructions
MANAGER PROGRAMMING
CHANGING YOUR CODE
(Without
eKEY or eKEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
If your unit is programmed for Dual Code, each code must be
changed independently.
1
Enter existing code and hold down the last digit until unit
double signals twice and the LED stays on.
2
Press the “0” key.
3
Enter your NEW six (6) digit code two times.
m
If a mistake is made wait thirty (30) seconds and repeat steps
1
-
3
.
4
Test unit operation several times before closing the door.
• Valid Code Entry
- Double signal after valid six (6) digit code is
entered.
• Invalid Code Entry
- Triple signal and old code is still valid.
MANAGER CODE MUST BE CHANGED PRIOR TO
PERFORMING ANY ACTION OTHER THAN OPENING THE
LOCK
OPENING THE LOCK
(Without
eKEY or eKEY
II
)
1
Enter valid six (6) digit code.
2
The unit will indicate a valid code entry with a double signal.
3
Within four (4) seconds open lock by either rotating the keypad
to open position (Clock-wise) or turning the handle to the open
position.
4
Pull door open.
• Invalid Code Entry
- Unit will signal three (3) times.
Suggested Keypad
ACTIVATING USER
(Manager Only, without eKEY or eKEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1
Enter Manager code and hold down last digit of code until unit
double signals twice and the LED stays on.
2
PRESS 1. Unit signals twice.
3
Press User number, 2 to 9. Unit signals twice.
4
Enter NEW six (6) digit User code two times.
5
If a mistake is made wait thirty (30) seconds and repeat steps
1
-
4
.
• Valid Code Entry
- Double signal after valid six (6) digit code is
entered.
• Invalid Code Entry
- Triple signal and old code is still valid.
DISABLE USER
(Manager Only, without eKEY or eKEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1
Enter Manager code and hold down last digit of code until unit
double signals twice and the LED stays on.
2
PRESS 2. Unit signals twice.
3
Press User number, 2 to 9. Unit signals once.
4
User is temporarily disabled.
5
If a mistake is made wait thirty (30) seconds and repeat steps
1
-
3
.
• Valid Code Entry
- Double signal after valid six (6) digit code is
entered.
• Invalid Code Entry
- Triple signal and old code is still valid.
STANDARD FEATURES
MANAGER CODE
(Factory set to 1-2-3-4-5-6 or 7-8-9
depending on code length)
• Activate/Delete Users
• Enable/Disable Users
• Set Time Delay Values
• Open Lock
USER CODE
• Open Lock
• Change Code
TIME DELAY
• Delay period 1 - 99 minutes
• Open period 1 - 19 minutes
DUAL CODE
• Two codes required to open
SIGNAL TO DISABLE LOCK OPENING
(Optional Alarm Box
Required)
• Input signal disables opening of lock by valid code
WRONG TRY PENALTY
• Four (4) consecutive invalid codes initiates five minute
delay period.
LOW BATTERY WARNING
• Repeated audio and visual signal (LED flashing and
repeated beeping) during opening indicates battery low.
AUDIO AND VISUAL SIGNAL
• Double signal (LED flashes and unit beeps) indicates
entry is valid or accepted.
• Triple signal indicates invalid or not accepted.
AUDIT TRAIL
• For audit features see LPAUDIT Software Package
3750-K
Round Entry
PC PROGRAMMABLE FEATURES
MULTIPLE USERS
Up to nine (1 Manager and 8 Users)
User # Installed 2 3 4 5 6 7 8 9
ACTIVE
CODE LENGTH
TIME DELAY OVERRIDE
• Ability to add second combination to override delay
period
SILENT SIGNAL ALARM
(Optional Alarm Box Required)
• Duress signal if last number of code(s) is entered using
one number higher or one number lower.
SIGNAL TO DISABLE LOCK
(Optional Alarm Box Required)
• Input signal disables all lock functions by valid code
eKEY
or
e
KEY
II
• Use of key and code required
Lock Choices
4300
Dual-Handed Swingbolt
6040-DB
Deadbolt
•
All locks are shipped from the factory in Pre Set-up
mode, with no features installed.
•
Lock will open when 1 is pressed.
•
Please follow LPAUDIT PC software instructions to
initially configure locks to default settings.
4300 is a new part
number replacing the
6260
3125 Round
Entry