background image

INTRODUCTION

EN

 

This instruction sheet provides you with the information required 
to safely own and operate your product. Retain these instructions 
for future reference.
The product you have purchased is of the highest quality 
workmanship and material, and has been engineered to give you 
long and reliable service. This product has been carefully tested, 
inspected, and packaged to ensure safe delivery and operation. 
Please examine your item(s) carefully to ensure that no damage 
occurred during shipment. If damage has occurred, please 
contact the place of purchase. They will assist you in replacement 
or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE 
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE 
YOUR PRODUCT. KNOW THE PRODUCT’S APPLICATION, 
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT 
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 
INFORMATION. FAILURE TO COMPLY WITH THESE 
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY 
AND/OR PROPERTY DAMAGE!

SAFETY GUIDELINES

 1. Make certain that the unit is disconnected from the power 

source before attempting to service or remove any 
component.

 2. Do not use to pump flammable or explosive fluids such as 

gasoline, fuel oil, kerosene, etc. Do not use in explosive 
atmospheres. Pump should only be used with liquids 
compatible with pump component materials.

 3. Do not handle pump with wet hands or when standing on a 

wet or damp surface or in water.

 4. This pump is supplied with a grounding conductor and/or 

grounding type attachment plug. To reduce the risk of electric 
shock, be certain that it is connected to a properly grounded 
grounding type receptacle.

 5. In any installation where property damage and/or personal 

injury might result from an inoperative or leaking pump due to 
power outages, discharge line blockage, or any other reason, 
a backup system(s) and/or alarm should be used.

 6. Support pump and piping when assembling and when 

installed. Failure to do so may cause piping to break, pump to 
fall, motor failures, etc.

ELECTRICAL CONNECTIONS

 1. Check the pump label for proper voltage required. Do not 

connect to voltage other than that shown.

 2. If pump is supplied with a 3-prong electrical plug, the third 

prong is to ground the pump to prevent possible electrical 
shock hazard. DO NOT REMOVE the third prong from the plug. 
A separate branch circuit is recommended. Do not use an 
extension cord. Do not cut plug from the cord. If the plug is cut 
or the cord is shortened, then this action will void the warranty.

  3. The National Electric Code requires that a ground fault circuit 

interrupter (GFCI) be used in the branch circuit supplying 
fountain pumps and other pond equipment. See your electrical 
supplies dealer for this device.

  4. To reduce the risk of electric shock, use only on portable self-

contained fountains no larger than five feet in any dimension.

CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER 
ASSEMBLY AND DISASSEMBLY OF YOUR LITTLE GIANT PUMP.

PUMP CONSTRUCTION

The patented Little Giant magnetic drive pump design consists 
of a cylindrical drive magnet attached to the motor shaft which 
rotates around a chemical resistant plastic separator housing. 
Inside this housing is a magnet completely encapsulated in 
chemical resistant plastic, and fixed to the impeller. The impeller 
assembly is free to rotate on a spindle that is supported at both 
ends. The spindle is held captive and does not turn. Front and 
rear thrust washers are utilized as wear bearings. The washers are 
held captive and do not revolve. This prevents wear on the shaft. 
With the magnetic coupling the motor drives the impeller. This 
coupling eliminates the conventional shaft seal and its possibility 
of leakage.
Two series are available. The HC series handles highly corrosive 
chemicals at elevated temperatures because of the unique 
materials used in its construction. The SC series handles semi-
corrosive fluids. Both series are available with various size pumps, 
and are available in 115V or 230V, 50/60 Hz versions.
The HC models utilize a carbon bushing between the impeller and 
spindle. The use of this carbon bushing will allow these pumps 
(HC series) to run dry (without fluid) for up to eight hours at a time. 
Do not allow the SC models to run dry. They do not have the 
carbon bushing and heat build up caused by friction will damage 
the parts when SC models are run dry.

PUMP MATERIALS

The plastic parts on SC series pumps are made of glass-filled 
polypropylene. The plastic parts on the HC series pumps are 
glass filled PPS. The spindle shaft which is stationary and the 
captive thrust washers (front and rear) are alumina ceramic. The 
O-ring seal is Nitrile for the SC series, and Fluoroelastomer (FKM) 
for the HC series. The HC series utilizes a pure carbon bushing in 
the impeller to enable the pump to run dry for periods up to eight 
hours at a time.

INSTALLATION

Your Little Giant pump is delivered to you completely pre-assembled 
and pretested from the factory. It is ready for immediate use. The 
pump may be installed in any position. It may be mounted 
vertically with the pump head down. Proper plumbing connections 
should be made. See specification table to determine what size 
intake and discharge your pump has. Use a thread sealer on all 
pipe connections and hand tighten only. NOTE: On HC models a 
roll of PTFE pipe seal tape is supplied. Do not use a wrench to 
tighten the HC model connections. Excessive force may damage 
the plastic part. Make sure the wing nuts are tight before operating 
the pump.
Motor nameplates list all electrical data and wiring schematic. 
Make sure the pump is connected to proper voltage before operating. 
When wiring pumps with no plug, the green (or green/yellow) wire 
is the ground. The other two wires are line (live).
Do not allow the SC models to run dry (without fluid). However, 
because the HC models utilize a carbon bushing in the impeller 
they may be allowed to run dry for periods up to eight hours at a 

1

5-MD-SC

5-MD-HC

TE-5-MD-SC

TE-5-MD-HC

Franklin Electric Co., Inc.

Oklahoma City, OK 73127

www.LittleGiantPump.com

CustomerService@lgpc.com

Summary of Contents for 5-md-sc

Page 1: ...PUMP CONSTRUCTION The patented Little Giant magnetic drive pump design consists of a cylindrical drive magnet attached to the motor shaft which rotates around a chemical resistant plastic separator housing Inside this housing is a magnet completely encapsulated in chemical resistant plastic and fixed to the impeller The impeller assembly is free to rotate on a spindle that is supported at both end...

Page 2: ...se qui vous l a vendu Si une réparation ou un remplacement est requis elle vous prêtera assistance LIRE ATTENTIVEMENT CES DIRECTIVES AVANT DE PROCÉDER À L INSTALLATION À L UTILISATION OU À L ENTRETIEN DU PRODUIT SE FAMILIARISER AVEC LES APPLICATIONS LES LIMITES ET LES RISQUES POTENTIELS DU PRODUIT ASSURER SA PROPRE PROTECTION ET CELLE DES AUTRES EN SUIVANT TOUTES LES RÈGLES DE SÉCURITÉ LE NON RESP...

Page 3: ...s fils sont sous tension Nes pas faire fonctionner à vide les modèles SC Toutefois less modèles HC peuvent tourner à vide durant un maximum de 8 heures consécutives grâce à un coussinet d usure en carbone Ces modèles ne sont cependant pas submersibles Ne faire fonctionner les pompes qu en série et ne pas les immerger Elles debraient être placées dans un endroit secretary à l abri des éclaboussures...

Page 4: ...re el impulsor y el eje La utilización de este buje de carbón le permitirá a estas bombas serie HC funcionar en seco sin fluido por un tiempo de hasta 8 horas cada vez No deje que los modelos SC funcionen en seco No tienen el buje de carbón y el calor acumulado causado por la fricción dañará las piezas cuando los modelos SC funcionan en seco MATERIALES DE LA BOMBA Las partes plásticas en las bomba...

Page 5: ...cordón eléctrico esté en buen estado y que no tenga hendiduras ni cortes SPECIFICATIONS MODEL INTAKE SIZE DISCH SIZE MOTOR MOTOR TYPE MAX PSI kPa SHUTOFF HEAD FT M GPM LPM VOLTS HZ RPM PH H P WATTS AMPS 6 FT 1 8M 9 FT 2 7M 15 FT 4 6M 18 FT 5 5M 24 FT 7 3M 5 MD SC 1 FNPT 1 2 MNPT 115 230 60 3000 1 1 8 208 2 0 OPEN FC PSC 11 9 92 1 27 5 8 4 17 5 66 2 15 3 57 9 14 0 53 0 10 9 41 3 9 2 34 8 4 4 16 7 1...

Page 6: ...cket 1 1 2 183031 Bracket 1 1 3 920008 Hex nut 8 32 1 1 1 1 4 183602 Drive magnet assembly 1 1 1 1 1 1 1 1 5 180057 Impeller shaft 1 1 1 1 1 1 1 1 6 182005 Magnet housing 1 1 1 1 6 182006 Magnet housing 1 1 1 1 7 911403 Collared stud 4 4 4 4 4 4 4 4 8 921077 Thrust washers 2 2 2 2 2 2 2 2 9 183139 Impeller assembly 1 1 1 1 9 183141 Impeller w bushing assembly 1 1 1 1 10 924007 O ring Nitrile 1 1 1...

Page 7: ...ECHNOLOGICAL REASONS This Limited Warranty gives you specific legal rights You may have other rights which vary according to the applicable laws and regulations Where any term of this warranty is prohibited by such laws it shall be null and void but the remainder of this warranty shall remain in full force and effect DISCLAIMER Any oral statements about the product made by the seller the Company t...

Page 8: ...da ESTA GARANTÍA NO APLICA A NINGUNO DE LOS SIGUIENTES CASOS 1 Cualquier producto que no se instale aplique mantenga y utilice según las instrucciones publicadas de la Compañía códigos aplicables ordenanzas aplicables y o estándares industriales generalmente aceptados 2 Cualquier producto que haya sufrido uso indebido mala aplicación descuido alteración accidente abuso modificación actos de Dios r...

Reviews: