background image

 

 

 

 

OWNERS MANUAL 

Model AH-100 Furnace -100,000 Btu 
Model AH-170 Furnace -170,000 Btu 

 

 
 
 
 
 
 
 

 
 
 

 
 
 

 
 
 

 
 
 
 

 

 

 

 

LMF   MANUFACTURING 

 

 

Manufacturing Facility

 

900 Park Avenue 

Woolrich, PA 17779 

(570) 769-7775

 

Summary of Contents for America's Heat AH-100

Page 1: ...OWNERS MANUAL Model AH 100 Furnace 100 000 Btu Model AH 170 Furnace 170 000 Btu LMF MANUFACTURING Manufacturing Facility 900 Park Avenue Woolrich PA 17779 570 769 7775...

Page 2: ...confidence in that your Americas Heat Furnace will serve your heating needs now and for years to come We ask that you follow our policy of safety first when installing and using your Americas Heat fur...

Page 3: ...efficient and safe operation Have a qualified service person perform tasks you are not familiar with 8 Caution Children and adults should be alerted to the potentially high surface temperatures of th...

Page 4: ...Package includes 1 Fuel Delivery Coupler 1 Barometric Draft Control 1 Self Tapping Bolt 1 Hopper Hardware Bag 3 Wire Nut connectors 2 Wooden Handles 2 Insert burner auger assembly into burner auger t...

Page 5: ...mp securely It is advisable to install two sheet metal screws not supplied thru the clamp auger boot and into the hopper bin outlet to insure a permanent connection Install fuel delivery coupler betwe...

Page 6: ...nnect the Americas Heat furnace to a lined masonry chimney acceptable to the authority having jurisdiction USA installation may also use a residential type and building heating appliance chimney Canad...

Page 7: ...I Fig 1 YllUl...

Page 8: ...ol See Installation Adjust ment If flue pipe is made of material too heavy to bend out into collar make the diameter of the opening within lh of the inside diameter of the collar THERMOSTAT WIRING Con...

Page 9: ...d be followed at the beginning of each heating season This procedure should also be followed if the hopper is allowed to empty and the resulting sticky smoke film coats the hopper feed auger Powdered...

Page 10: ...red wire Blower speed can be changed by accessing the other wires behind the left side air filter Disconnect the black to black wire and reconnect to the desired colored wire using existing wire nut...

Page 11: ...ner with a furnace poker or equivalent tool 2 Check corn or pellet level in holding bin for adequate supply Weekly 1 Check contents of ash drawer and empty as needed Ashes should be placed in a metal...

Page 12: ...re the precise draft control A setting of 02 03 is ideal In most installations the counter weight on the automatic barometric dampers should be set on the minimum setting Adjusting the on and off cycl...

Page 13: ...11 REPAIR PARTS Cabinet ModeiBM 620 9...

Page 14: ...TRIM 9 6440 ASH DRAWER TRIM 1 Jo A 6040 FURNACE FLOOR 11 6220 FRONT PANEL 12 6200 COLD AIR WALL 13 6280 15_ IDE PANEL LEFT OR RIGHT HANDED FURNACEL 14 6240 RIGHT SIDE PANEL AUGER HOLE Ot _THE_RIGHT SI...

Page 15: ...12 REPAIR PARTS Model AH 170 Cabinet 11 16 Q 18...

Page 16: ...7 A 4180 BURNER DOOR 8 6460 DOOR TRIM 9 6440 ASHDRAWER TRIM 10 A 6040 FURNACE FLOOR 11 6220 FRONTPANEL 12 5050170 BLOWER HOUSING 13 6280170 BLANK SD I E PANEL LEFT OR RIGHT HANDEDFURNACE 14 6240 RIGHT...

Page 17: ...r 4 3 KEY PART NUMBER PART DESCRIPTION 1 5700 BURNER HEAT SHIELD 2 5680 HEAT DEFLECTOR 3 5660 SIDE HEAT SHIELD 4 5640 TOP HEAT SHIELD 5 A 5720 HEAT EXCHANGER 6 2200 WOODEN HANDLE 7 2040 5 16 x 1 SHOUL...

Page 18: ...REPAIR PARTS Electrical tJ 20 6 14...

Page 19: ...NG 12 1360 JUNCTION BOX 4 X4 13 1400 JUNCTION BOXCOVER 4 X4 14 1300 EMT CONDUIT 36 LONG 15 1640 FAN UMITCONTROL 16 1840 COMPLETE BLOWER 1 7 2080 FURNACE FILTER 20 X20 X 1 18 1860 COMBUSTION BLOWER 19...

Page 20: ...7 A 4180 BURNER DOOR 8 6460 DOOR TRIM 9 6440 ASH DRAWER TRIM 10 A 6040 FURNACE FLOOR 11 6220 FRONT PANEL 12 5050170 BLOWER HOUSING 13 6280170 BLANK SIDE PANEL LEFT OR RIGHT HANDED FURNACE 14 6240 RIG...

Page 21: ...REPAIR PARTS Furnace Auger PART DESCRIPTION FURNACE AUGEFrMoTOR LOCK COLLAR 1 4 x 1 2 SELF TAPPING SOLT BURNER AUGER cc c c c SHEET METAL SCREW 10 x 1 3 4 r A U G _E R 8 U PPORT 6 x 6 BOX 16...

Page 22: ...f 9 10 KEY PART NUMBER PART DESCRIPTION 1 A 3220 HOPPER AUGER 2 3180 LOCK COLLAR 3 1880 HOPPER AUGER MOTOR 4 1410 6 x 6 BOX 5 A 3070 AUGER SUPPORT 6 2070 SHEET METAL SCREW 10 1 3 4 7 7530 RUBBER TEE 8...

Page 23: ...17...

Page 24: ...F731 BLOWER COMPLETE 2 4C710 WHEEL 3 A40152 MOTOR MOUNTING BRACKET 4 2C355 HOUSING SUPPORTS 5 8122420 VIBRATION PADS 6 HEX HD MACH SCREW 10 24 x 7 8 7 NUT 10 24 8 HEXHD THREAD CUTTING SCREW 10 x 3 _ 9...

Page 25: ...BLOWER AH 170 ASSEMBLED DIRECT DRIVE FURNACE BLOWER 18a...

Page 26: ...REPAIR PARTS Storage Bin Model KEY PART NUMBER PART DESCRIPTION 1 7520 BIN LID f 1 2 7500 BIN CAVITY 1 3 7510 BIN BASE 19...

Page 27: ...ating it with a return air system a return air plenum must be built The size of the plenum opening can be up to 21 x 21 square Before installing the plenum the air filters and filter rack may be remov...

Page 28: ......

Page 29: ......

Page 30: ...rm below and return this form along with the defective part within five 5 days If defective part is not returned within the allotted time your credit card will be charged Full Name of Buyer Address Ci...