background image

 
 
 

 

PUMP-Rec-12 Rev B 

PUMP 

Recommendation 

 

PUMP RECOMMENDATION FOR 

INTELLI-FIN 1500-2000 WATER HEATER 

 

Pump Specifications 

Part No. 

HorsePower 

Flanges 

Valute Material 

Flange Material 

Vendor 

Vendor Product Series 

Orientation 

ARM3072PAB 3/4  2-1/2"  Bronze 

Bronze 

Armstrong 

2B1060 

 

Vertical 

 
Installation Specifications 

  

Recommended for 

 

Based on 

      Pump 

Model Numbers 

Maximum GPM 

Installation Type 

  

Intelli-fin Wtr Htr, IW(N,L) 1500-2000 

90 GPM 

Single Water Heater piped to a Single Storage Tank 

ARM3072PAB 

Based on 

Based on 

  

  

Minimum Pipe Diameter 

Connecting piping 

  

  

2-1/2" 

Maximum 45 feet straight pipe with 6-Elbows, 2-Unions, 2-Ball Valves and 1-Cold Water Inlet Tee 

IMPORTANT: Read the Intelli-fin 1500-2000 Installation and Operation Manual.  If the planned system exceeds 
the pump capacity in flow and/or head see “Pump Curves-All Pumps” for alternate pumps and pump curves. 

 

 

OIL PORT

A

C

16” 

19-1/2” 

 
 
 

 

(See ¾ HP Curve) 

 
 
 
 
 

 

 
 
 
 
 
 
 

 

B

D

11-1/2” 

 
 
 
 
 
 
 

 

Reviews: