background image

Step 4:  Adjust Deadbolt Length – M220/C120 ONLY (

if necessary

Depending on door configuration, you may 

need to reverse the bar from long to short. 

Remove silver screws and plate from the inside  

body and reverse bar. Replace the plate and  

secure with silver screws. 

 

 

No. 

Part Name 

M220  C120  C150 

Outside Body 

Inside Body 

Rubber Trim Plate 

Mortised Striker (not shown) 

Surface Strike Plate 

Spindle 45-55 mm. 

Spindle 35-45 mm. 

Machine Screw M4 x 55 mm. 

Machine Screw M4 x 45 mm. 

10 

Wood Screw 

11 

Extra Code Tumblers (Red) 

12 

Extra Non-Code Tumblers (Blue) 

13 

Spacers for Body (1/16” / 5/64”) (Not Shown) 

14 

Thin Door Kit (TDK) (Not Shown) 

15 

Hex Bolts 

16 

Tweezers 

Step 6:  Install the Lockey M220/C120/C150 

1.

 

Place the Rubber Trim Plate (#3)  

on the backside of the Outside  

Body (#1).   

2.

 

Place the Outside Body on the  

door. The hexagonal bolts (#15)  

should extend into the top and  

bottom holes.  

3.

 

Insert the Spindle (#6/7) through the door  

into the Spindle Hole in the Outside Body. 

4.

 

Place the Rubber Trim Plate (#3) on the backside of Inside Body. 

5.

 

Place the Inside Body to the door ensuring that the Spindle is 

inserted into the Spindle Hole. 

6.

 

If the Inside Body is not flush with the Surface Strike location, use 

Spacers (#13) to make Inside Body flush with Strike location. 

NOTE: If Spacers to not make Inside Body flush with Strike location, 

you may need to trim the door jamb or mortise the strike. 

7.

 

Insert the M4 Screws (#8/9) into the top and bottom holes of the 

Inside Body and secure with a screwdriver. 

8.

 

Test the lock to ensure the Deadbolt/Hookbolt is retracting correctly 

when turning the inside/outside knob. 

9.

 

Install Strike Plate in proper position and secure with Wood Screws. 

 

Step 5:  Verify Correct Spindle Length 

1.

 

Hold the Inside Body (#2) and Rubber  
Trim Plate (#3) to the door. 

2.

 

Place Spindle (#7) through door into the  
Inside Body, as far as possible. 

3.

 

Spindle should extend from exterior of door 
3/8” min. – 5/8” max. 
 

4.

 

If Spindle is too long, cut it to the correct length using Pliers. 

IMPORTANT: If spindle extends less than 3/8” it may not engage the lock.  If spindle 
extends more than 5/8”, it will cause the lock to bind.

 

Step 3:  Identify Door Handing 

Right-Hand Doors – From exterior of 
door, hinges are on right-side. (Fig. 1) 

Left-Hand Doors – From exterior of  
door, hinges are on left-side. (Fig. 2) 

The M220, C120 and C150 are factory pre-handed  
for right-hand doors.  To change handing,  
remove two (2) blue screws and cover plate  
from Outside Body as shown. 

Now, move the pin from the right side  
of the outside body to the hole on the left side.  
Replace plate and screws. 

Lockey Surface Mount 
Installation Instructions 

Step 2:  Prep Door for Installation with Template 

BEFORE DRILLING – PLACE INSIDE BODY (#2) AND STRIKE TO DOOR TO 

ENSURE POSITION WILL BE APPROPRIATE FOR INSTALLATION. YOU MAY 

NEED TO TRIM DOOR JAMB OR MORTISE THE STRIKE TO INSTALL.

 

1.

 

Place template (supplied) on door and fold along door’s edge. 

2.

 

Depending on door configuration, you may need to change 

handing and/or reverse bar (M220/C120) from long to short.  See 

Steps 3 and 4. 

3.

 

Drill holes as instructed and mark location for Strike. 

 

 

Inside Body (#2) 

Step 1:  Change User Code (

OPTIONAL

)

 

If you wish to change your code, see instructions on reverse side. 

 

M220 Deadbolt | C120 Deadbolt | C150 Hookbolt 