background image

USER MANUAL

SMART SAFE

ERP机型:

PL45E1UQ-US-SMT00010A-V1

Designed:Walter

Date:2022-08-08

描述: 说明书:PL45E1UQ/PGV528,SMT000,REV.A(UMPGV528W20220808),196×196MM,

           封面&底面:128g双粉纸双面过哑油,单黑印刷,内页80g书纸,双面印单黑,22页44面装订本,

            RoHS2.0,REACH,Prop65,POPs,PAHs

ERP P/N:

REV:1.1

K

Y

M

C

R

6

4 3

0

7 2

8

1 4

5

3 9

Summary of Contents for PL45E1UQ

Page 1: ...SAFE ERP PL45E1UQ US SMT00010A V1 Designed Walter Date 2022 08 08 PL45E1UQ PGV528 SMT000 REV A UMPGV528W20220808 196 196MM 128g 80g 22 44 RoHS2 0 REACH Prop65 POPs PAHs ERP P N REV 1 1 K Y M C R 6 4 3...

Page 2: ......

Page 3: ...fety Precautions 1 2 3 4 6 7 5 8 9 10 12 14 15 18 20 21 24 25 27 33 34 29 30 32 35 36 37 2 1 Product Overview Exterior 2 2 Product Overview Interior 2 3 Understanding Your Smart Safe 2 4 Rebooting You...

Page 4: ...e Smart Safe from being moved or stolen Air Transfer compatible Quickly transfer fingerprint and trusted user profiles from your Lockly smart locks to you Smart Safe Hydraulic Easy Lift Unlocking Unlo...

Page 5: ...2 1 Product Overview Exterior 2 SECTION 2 1 Fingerprint Reboot Button Bluetooth light OK Button Keypad Buttons Touchscreen Key Hole...

Page 6: ...artment Flashlight Type C Port SECTION 2 2 3 2 2 Product Overview Interior Program Button When the Safe opens the light automatically turns ON and OFF after 2 minutes Touch the keypad to turn ON the l...

Page 7: ...Safe adding Access Codes deleting Access Codes adding and deleting fingerprints and how to configure your OAC Offline Access Code For any questions you can always visit https Lockly com help for assis...

Page 8: ...ss and release the reboot button when you want to reboot the Safe Your Lockly will beep once after reboot Only reboot when necessary You will need something small such as a paperclip to press the rebo...

Page 9: ...isplay a low battery icon Dead Battery Condition Indicator Solution Low Battery Battery Icon on the display keypad will light up to indicate low battery Replace batteries immediately to avoid battery...

Page 10: ...are oriented correctly by matching the orientation displayed Replacing the batteries do not reset stored Access Codes To see a list of recommended brands please visit http Lockly com battery NOTICE Pr...

Page 11: ...tton on the right is the OK button You will be pressing this button when you are done entering your Access Code We recommend pairing the Safe to your smart phone to manage your access codes Section 3...

Page 12: ...twice to enter programming mode Note Once the smartphone is connected 1 PG Programming mode will be disabled Configure all settings via synced smart phone Access Codes previously added by 1 PG Progra...

Page 13: ...Enter your new 6 8 digit Access Code and press when you are finished You will then re enter the code to confirm your new Access Code Remember just touch the digit you need within the circle around ea...

Page 14: ...you will see the new code displayed here In this example we chose 123456 Press to Confirm or to cancel To exit or cancel you can always press or If the two 2 Access Codes you entered does not match a...

Page 15: ...E press Pd to delete an Access Code OK Button Example Only Active Access Codes will then be displayed on the screen in sequence from left to right As shown on the above example the Access Code display...

Page 16: ...xample 1 2 3 4 5 6 Press to delete or to cancel There are two incidents where your Access Code cannot be deleted Only one Active Access Code No Access Codes Set 1 There There are no Access Codes set 2...

Page 17: ...he screen in sequence from left to right In the example shown on the left the Access Code displayed is 1 2 3 4 5 6 Scan through the different Access Codes by touching any number on the screen To exit...

Page 18: ...rs before registration to make sure the finger you want to register will be acceptable by our system Otherwise use an alternative finger to ensure successful registration The following examples show w...

Page 19: ...of Lockly Smart Safe Once you re in Fingerprint Registration Mode you will see two numbers displayed on keypad The top number is your Fingerprint Registration number in this example above 1 The botto...

Page 20: ...your finger and repeat the process slowly until the digit 6 shown on the screen becomes 1 If you have successfully scanned and registered your fingerprint you will hear a long beep and the Bluetooth i...

Page 21: ...sensor equipped in your Smart Safe is loaded with powerful fingerprint algorithms to extract quality features from fingers even in poor conditions Placing your finger on the sensor correctly helps con...

Page 22: ...3 7 Fingerprint Scanning Directions Continued Top View Side View OK OK Correct Incorrect 19 SECTION 3 7...

Page 23: ...commended to use fingerprint access due to the constant changes of their fingers during growth Elderly with fading fingerprints may have difficulty in recognition If your finger has a cut scar or crac...

Page 24: ...r 3 seconds to delete Example shown 01 You will then see a confirmation page displaying and with the fingerprint number you are deleting displayed on the left Select Y to delete or N to cancel Alterna...

Page 25: ...will put Lockly in Safe Mode See Section 4 7 If you need to lock the Safe close and press the top cover You may toggle between two types of keypad displays to enter your Access Code The fixed digit v...

Page 26: ...int please see Section 3 6 If your fingerprint is registered and acknowledged you will hear a beep sound Green LED will light up on the fingerprint scanner and Smart Safe will pop and open If you see...

Page 27: ...Lockly with App You must have the Lockly iOS or Android app installed in order to unlock with smartphone Please download the app by visiting the link below or search Lockly from the correct app store...

Page 28: ...ng difficulty setting up optimal range of 30 ft or less we re here to help Call our customer care team 669 500 8835 or visit Lockly com help for suggestions and troubleshooting tips To set up your Loc...

Page 29: ...at your Secure Link Wi Fi Hub is ready to connect to your Safe open the Lockly App from your smartphone Make sure you are standing between the Wi Fi hub and Lockly Smart Safe then Add New Device and f...

Page 30: ...NEW DEVICE Select A Device Select Lockly Smart Safe GET STARTED Scanning LOCK SERIAL Input Activation Code If you can t scan LOCK SERIAL Then enter manually AT T 9 41 AM 100 AT T 9 41 AM 100 AT T 9 42...

Page 31: ...ing OK Plug in your Secure Link and Click YES Set Wi Fi Click Yes when the green light is on Successfully Added AT T 9 49 AM 100 AT T 9 47 AM 100 AT T 9 46 AM 100 AT T 9 45 AM 100 Congratulations Your...

Page 32: ...king with Physical Key Exterior View To unlock your Safe using the physical key included insert your key and turn counterclockwise to unlock the Safe Please keep physical key separately and do not put...

Page 33: ...tes You will see a 10 on the screen notifying the number of minutes that the keypad is disabled for After 10 minutes you may attempt to enter the correct Access Code to unlock the Safe After the secon...

Page 34: ...disable Safe Mode If you have not downloaded the app to use with your Safe you won t be able to use this option to disable Safe Mode While in Safe Mode the keypad will not lit up when you are using yo...

Page 35: ...y need to adjust the brightness to their convenience to enter access codes Swipe your fingers across the keypad to light up to its normal brightness To adjust brightness long press the first button fr...

Page 36: ...cess Code within the app Go to Access and choose Add a New User then select Offline Access Code OAC and follow on screen instructions to generate your Offline Access Code Understanding Offline Access...

Page 37: ...t Sub Admin will be able to grant limited access codes to users when within Bluetooth range Once Sub Admin control is setup you as the Admin will no longer be able to issue Offline Access Code OAC The...

Page 38: ...You may find an Activation Code Card with an Activation Code included in your package It is very crucial that you do not lose this card Please store this card safely as you will need the default Activ...

Page 39: ...with a damp lukewarm cloth Air dry or wipe dry with a soft microfiber cloth to avoid scratches Don t use abrasives high alkaline cleaners or gasoline to clean your safe Don t apply cleaning detergent...

Page 40: ...ent unwanted access of your valuables Please keep your Access Codes safe Check your settings regularly to ensure Access Codes have not been changed without your knowledge Always dispose of used batter...

Page 41: ...ment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipm...

Page 42: ...promettre le fonctionnement IC Radiation Exposure Statement This equipment meets the exemption from the routine evaluation limits in section 2 5 of RSS 102 It should be installed and operated with a m...

Page 43: ......

Page 44: ...No US 9 665 706 B2 USA Patent No US 11 010 463 B2 AUS Patent No 2013403169 AUS Patent No 2014391959 AUS Patent No 2016412123 UK Patent No EP3059689B1 UK Patent No EP3176722B1 Other Patents Pending The...

Reviews: