background image

ASK-4

®

 # 101-DP

AUDIO MONITORING SYSTEM

6955 VALJEAN AVE. VAN NUYS, CA 91406   PH: 818-994-6489  | FAX: 818-994-6485 | TECHSUPPORT@LOUROE.COM | WWW.LOUROE.COM

INSTALLATION AND OPERATING INSTRUCTIONS

ASK-4

®

 # 101-DP (LE-367)

The ASK-4® #101-DP is a single zone audio monitoring system designed to interface with a DVR, VCR or other recording devices that accept line 

level input.  The APR-1 Audio Base Station contains a built-in 3” speaker and volume control for producing live audio and audio playback. The 

microphone is mounted in the back of the face plastic plate that can used on a single gang electrical box for flush mounting.

 

KIT CONTENT

PRODUCT NAME

DESCRIPTION

APR-1 

(LE-146)

listed Audio Base Station. Used for listening to live audio from microphone, as well as

audio playback from DVR’s, VCR’s or other audio devices. 

Verifact™ “DP” Mic

(LE-003)

Microphone Electret condenser microphone with preamp. Picks up normal sounds 15’ away (wall mounted) or within a 

30’ diameter (ceiling mounted). May be located Up to 1000’ from APR-1 Base Station.

AD-1

listed AC ADAPTER. Supplies 12 Vdc to APR-1 and Microphone.

Dual RCA Cable

RCA cable for connection to a DVR/VCR or other Audio devices that accept line level input

APR-1

SINGLE ZONE 

AUDIO BASE ST

ATION

PWR

MUTE

MUTE

PUSH FOR 

PLAYBACK

PLAYBACK

OVERLOAD

[1] Power-Volume

[6] Mute Switch

[7] Push for Playback

[8] Headphone Jack

[9] Speaker

[2] Power Indicator

[3] Mute

[4] Playback Indicator

[5] Overload Indicator

[10] Power Jack

[12] Audio Out Jack (RCA)

[13] Audio Terminal Block

[11] Audio In Jack 

MIC INPUT

INPUT

+12Vdc

OUTPUT

MIC INPUT

A     B     C

PART DESCRIPTION

[1]

Power-Volume

Turns “ON” power to the unit and controls the audio 

volume through the Speaker[9].

[2]

Power Indicator

Lights (green) when the power is present to the unit.

[3]

Mute Indicator

Lights (orange) when Mute Switch[6] is pushed in. 

Audio is muted.

[4]

Playback 

Indicator

Lights (yellow) when Push  for  Playback[7] is 

pushed in to “ON” position.

[5]

Overload 

Indicator

Flashes (red) when there is a short in the power 

supply.

[6]

Mute Switch

Used to mute the audio on both live and playback 

mode.

[7]

Push for play-

back

Used for DVR/VCR playback. May also be used 

to listen to audio from an external source. Press 

switch to listen to playback. Switch must be “OUT” 

or “OFF” when monitoring and recording, otherwise 

live audio is muted

[8]

Headphone 

Jack

Used for private listening. Any 3.5mm stereo 

headphone with 8Ω to 600Ω impedance can be 

used.

[9]

Speaker (3”)

Provides live audio.  Muted when a headphone is 

connected to Headphone Jack [8].

[10] Power Jack

Accepts 12Vdc power from Model AD-1 Power Sup-

ply

 

(included with APR-1 Audio Base Station).  AD-1 

has a 90° 2.1mm female plug.

[11] Audio in Jack 

(RCA)

Accepts audio playback from an external source 
(DVR/VCR).

 

Audio playback is produced through 

the speaker. The Push for Playback[7]

 

must be “IN” 

during audio playback and “OUT” when not used for 
playback.

[12] Audio Out Jack 

(RCA)

Provides audio output and connection to a DVR, 

VCR, etc.

[13] Audio Terminal 

Block

A 3-pin terminal block marked A, B, C. Accepts 
wiring from the remote Louroe™ Microphone.

• 

A is 12Vdc

• 

B is Audio

• 

C is Ground

APR-1  

(LE-146)

Page 1

Summary of Contents for LE-367

Page 1: ...Jack 12 Audio Out Jack RCA 13 Audio Terminal Block 11 Audio In Jack MIC INPUT INPUT 12Vdc OUTPUT MIC INPUT A B C PART DESCRIPTION 1 Power Volume Turns ON power to the unit and controls the audio volume through the Speaker 9 2 Power Indicator Lights green when the power is present to the unit 3 Mute Indicator Lights orange when Mute Switch 6 is pushed in Audio is muted 4 Playback Indicator Lights y...

Page 2: ...anel of DVR with RCA Type Aduio Input APR 1 LE 146 Back Panel INTERCONNECTION DIAGRAM VERIFACT DP MICROPHONE TO APR 1 BASE STATION TO DVR ETC VERIFACT DP LE 003 WIRING REQUIREMENTS Both the Verifact DP Microphone and APR 1 Audio Base Station contain a 3 pin terminal block marked A B C 2 Conductor shielded cable 22 gauge with a 24 gauge drain wire NOTE Unshielded cable is not satisfactory for audio...

Page 3: ...ate feedback with the APR 1 The fur ther the microphone is from the APR 1 the less feedback it generates Sys tem works best if there is an acoustical barrier between the microphone and the APR 1 such as a wall or room divider If there is no wall or barrier mi crophone should be mounted at least 25 ft from the APR 1 Base Station 4 Plug headphone into the Headphone Jack 8 Speaker 9 output is muted a...

Page 4: ...LECTRONICS shall be at customer s expense LOUROE ELECTRONICS will return the equipment prepaid via best way ABOUT LOUROE ELECTRONICS Located in Van Nuys California and 32 years young Louroe Electronics has been the world leading Audio Manufacturer Our continued growth has resulted from providing innovative products receiving high customer sat isfaction maintaining strict devotion to quality standa...

Reviews: