background image

 

 

Because you’re not like everyone else. 

 

 

E

VAPORATIVE 

C

OOLER

 

EC

220

O

WNER

M

ANUAL

 

 

Summary of Contents for EC220W

Page 1: ...Because you re not like everyone else EVAPORATIVE COOLER EC220W OWNER S MANUAL ...

Page 2: ...e any questions or concerns regarding your product or if you would simply like to share an idea with us please feel free to contact us Our friendly and knowledgeable customer support team is here for you Call us today at 866 737 6390 or email support lumacomfort com For future reference we recommend you attach a copy of your sales receipt here and record the following information You will need thi...

Page 3: ...ing the Hose Connector 9 Adjusting the Air Louvers 9 Maintenance 10 Exterior Cleaning 10 Cleaning the Cooling Pads 10 Water Tank Cleaning 11 Water Pump Maintenance 11 Technical Support 12 Product Specifications 12 Troubleshooting 13 Warranty 14 SAVE THESE INSTRUCTIONS Please carefully read this manual before attempting to use this evaporative cooler For your own safety comply with all safety instr...

Page 4: ...ptacle Under no circumstances should the plug be altered in any way An improper connection can result in electric shock 8 If possible avoid using extension cords with this evaporative cooler If an extension cord is absolutely necessary do not use more than one extension cord and do not use a single extension cord to operate more than one cooler 9 Do not insert objects or allow fingers to enter int...

Page 5: ... directly to a standard garden hose for continuous water supply Powerful motor results in more powerful airflow faster evaporation and cooler air Eco friendly evaporative cooling system cools the air by the natural process of evaporating water with no Freon or harmful chemicals Adds moisture to dry environments and eliminates airborne dust particles Covers up to 650 square feet PARTS LIST Check to...

Page 6: ... 1 Top Panel 2 Right Panel 3 Louver lever 4 Air louvers 5 Water tank 6 Caster 7 Water level indicator 8 Control panel 9 Carrying handle 10 Left Panel 11 Continuous water inlet 12 Drain plug 13 Water inlet 14 Back panel THE CONTROL PANEL ...

Page 7: ...oling effect Turn on your evaporative cooler before the ambient temperature reaches excessively high levels Due to the low operating costs of the unit it is very cost effective to leave the cooler running for extended periods Add cold water to the tank Ice can also be added for an enhanced cooling effect After adjusting the COOLER dial the unit s high efficiency cooling pads will become damp Air i...

Page 8: ... effect wait a few minutes for the cooling pads to become fully saturated with water 5 Periodically check the water level on the water level indicator If the water tank is running low on water turn the COOLER dial to the OFF position and add more water ice 6 To turn the unit off turn the COOLER dial to the OFF position and the SPEED dial to the OFF position If the unit will not be used for an exte...

Page 9: ...should be approximately 0 5 of the PVC pipe extending out of the hose connector Attach a garden hose to the PVC pipe and clamp the two together using the metal clamp ADJUSTING THE AIR LOUVERS 1 To adjust the air louvers turn the SWING dial to the ON position The air louvers will automatically move horizontally improving the distribution of cooled air throughout your room 2 To turn off the automati...

Page 10: ... the cooler s parts with a soft cloth before reconnecting the unit to the power supply CLEANING THE COOLING PADS To prevent the cooling pads from becoming clogged with dust mineral deposits and other buildup we recommend that they be cleaned at least once a month 1 To remove the cooling pads use a Philips screwdriver to remove the side and rear panels 2 Rinse the pads with clean water to remove du...

Page 11: ...y any water from the tank 2 Pour the cleaner into the water tank and close it making sure the pump is submerged in the cleaner 3 With the tank closed allow the pump to soak for 10 to 20 minutes 4 Remove the cooling pads from the back and sides of the unit 5 Run the cooler for 30 seconds This will circulate the cleaning solution through the pump and tubing to remove any leftover mineral deposits Do...

Page 12: ...setup or operation please contact our product support team at 1 866 737 6390 or support lumacomfort com PRODUCT SPECIFICATIONS Model EC220W Product Dimensions 27 4 x 17 2 x 41 3 Product Weight 41 9 pounds Voltage 110V 120V Wattage 220W Coverage Area Up to 650 sq ft Tank Size 10 6 gallons Fan Speeds 3 Noise Level dB 68 Airflow 1650 CFM Oscillation Yes Warranty 1 year manufacturer s warranty ...

Page 13: ...he pump is defective a Check the water level in the tank and make sure there is enough water b Turn the COOLER dial to ON c Contact customer service if there is an issue with the water pump The unit does not sufficiently cool The cooling pad is not sufficiently saturated with water Allow the cooling pads to become fully saturated with water This may take a few minutes Water is coming out of the ve...

Page 14: ...r of parts that are designed to be replaced such as filters or batteries Power failure and improper power supply such as low voltage defective wiring or inadequate fuses Use of force or damage caused by external influences Complete or partially dismantled appliances THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY INCLUDING...

Reviews: