background image

INSTALLATION INSTRUCTIONS

LUMASCAPE USA INC

1300 Industrial Rd, Unit #19 

San Carlos, CA 94070, USA

  (650) 595-5862

W  www.lumascape.com
Free Call : (866) 695-5862

FORM IN0085US

Warranty void if not installed per instructions and local electrical code

www.lumascape.com

LS421LED

 Centria Surface Mount

MODEL: 

LS421LED Centria Surface Mount

INPUT VOLTAGE: 

120-277 V, 50/60 Hz

SPOTLIGHT AND FLOODLIGHT

IN0085US - 17 April 2014

WARNING

Do not use power tools to  

assemble or fasten.

For wall mount use only

Do not operate luminaire with missing or 

damaged components

Install in accordance with National  

Electric Code, ANSI/NFPA 70 or the Canadian 

Electrical Code, Part I (CEC), CSA C22.1

Drill J-box mounting holes

Insert mounting hole template into luminaire base and drill holes as required.
Remove template and punch or drill a hole for the supply wires.

2.

Fixing Holes

3.5” (88.9mm)

4" round/octagonal 

junction box, 

(by others).

Connect and mount luminaire base

Cover supply wires with insulation sleeve and connect luminaire to 
supply using terminal block. Refer to wiring diagram in back for details. 
Screw down luminaire base on junction box ensuring gasket seal is 
correctly inserted between junction box and luminaire base. If required 
use additional screws to mount luminaire base to mounting surface.

It is the installers responsibility to ensure proper seal 
against wall to stop moisture entering the fixture.

3.

fit gasket seal

fit insulation 

sleeve over 

supply wires

Make sure all power is isolated before you begin!

Run supply wires to the junction box on which the 
luminaire is to be installed.

1.

KEEP ELECTRONICS FREE 

FROM DIRT AND MOISTURE

COMPONENTS

x4

x4

x2

screw

screw

Allen key

mounting

hole template

seal

luminaire 

base

luminaire 

head

gasket seal

insulation 

sleeve

Seal luminaire

Connect the luminaire head to the base by first connecting the driver wires to 
the corresponding wires on the supply side using the terminal block. Refer to 
wiring diagram in back for details. Secondly screw the luminaire head to the 
base, ensuring the seal is correctly in place between the two components.

4.

1.5 ft lbf

seal

Reviews: