background image

 

 

www.luminator.com 

 
 
 
 
 
OPERATING & INSTRUCTION MANUAL 

Renew™ Air Treatment Solution | Version 1.0 

 

 

Summary of Contents for Renew System

Page 1: ...www luminator com OPERATING INSTRUCTION MANUAL Renew Air Treatment Solution Version 1 0...

Page 2: ...Mounting 9 4 4 Connections 9 5 Initial System Setup 10 5 1 Install the Atomizer 10 5 2 Install the Controller 10 5 3 Install the Sensor 10 5 4 Activate the Atomizer 10 5 5 Activate the Controller 11 6...

Page 3: ...isit www luminator com or contact technical support by email support na luminator com 1 4 SAFETY NOTES Do not submerge any components Always disconnect components from power before manual cleaning Do...

Page 4: ...mizer has been designed to allow for remote mounting directly into an HVAC plenum or duct to maximize dispersion characteristics of Grignard Pure in large spaces 3 For best results HVAC plenum or duct...

Page 5: ...MOUNT FIGURE 3 BRACKET POSITION FOR WALL MOUNT 2 5 CONNECTIONS 5 pin XLR Pin Receptacle connector Used to control the Atomizer Half duplex RS485 DMX Protocol RDM protocol Future Data GND 3 Pin Twist...

Page 6: ...forward values can account for the major portion of the controller output while allowing the automatic adaptive feedback control to account for the smaller deviations above the desired set point 3 2 P...

Page 7: ...Page 7 Used for configuration and monitoring of the system Hosted webpage for configuration at IP address 192 168 123 10 USB Standard USB Host Mode A Connector Utilized for data logging by installing...

Page 8: ...BETTER AS THEY WOULD CAUSE THE CONCENTRATION TO OVERSHOOT THE DESIRED LEVEL Atomizer On Time seconds Indicates the amount of time the Atomizer is ON dispensing Grignard Pure This allows for fine adju...

Page 9: ...flow E g Do not mount directly next to a HVAC air vent HVAC return air vent or ceiling fan The Sensor grating should be positioned parallel to the floor or pointing downward to prevent accumulation of...

Page 10: ...the Sensor to the Controller 5 4 ACTIVATE THE ATOMIZER 1 Ensure the tubing connecting the reservoir to the Atomizer is free of air bubbles NOTE REFER TO STEP 4 AFTER APPLYING POWER IF THE FLUID TUBE...

Page 11: ...eans the Sensor Fan c The system automatically calibrates based upon the background particulate matter PM levels NOTE BACKGROUND PM LEVELS ARE TYPICALLY 1 OF THE TOTAL PM THRESHOLD NOTE WITH EARLY SOF...

Page 12: ...stem does not need to be connected to a network in order to configure parameter settings on the Controller As the Controller is a fixed end point in a network it can not implement DHCP to assign an IP...

Page 13: ...c IP address is configured on the computer open a web browser e g Firefox Google Chrome or Internet Explorer and enter the fixed IP address 192 168 123 10 into the browser search bar 3 The status page...

Page 14: ...asium Comments DMX Channel 1 1 1 1 Should not change dependent on the Atomizer Fan Speed 125 255 125 255 Spaces with minimal air movement should use higher settings Max Atomizer Power 90 12 30 125 Thi...

Page 15: ...shown in the following figure FIGURE 7 CONTROLLER SOFTWARE UPGRADE 2 The application will ask you to confirm the upgrade as shown in the following figure FIGURE 8 CONTROLLER SOFTWARE UPGRADE 3 Once t...

Page 16: ...y adjust If the system is NOT connected to a network switch then the date and time can be adjusted manually NOTE EARLY VERSIONS OF THE CONTROLLER DO NOT FEATURE A BATTERY BACKUP REAL TIME CLOCK FOR MA...

Page 17: ...aptop and the Controller This procedure is not required in order for the system to operate it is only needed to change initial configurations settings on the Controller or to monitor system status 1 N...

Page 18: ...inator com Page 18 2 Select Change Adapter Settings FIGURE 11 ACCESSING NETWORK ADAPTER SETTINGS 3 Select the Local Area Connection right click and select Properties FIGURE 12 MODIFY LAN CONNECTION SE...

Page 19: ...IPv4 and click Properties FIGURE 13 CHANGE LOCAL AREA NETWORK SETTINGS 5 Select Use the Following Address and set the static IP Address and Subnet mask on the same subnet as the Controller Example 19...

Reviews: