background image

SD card, real time

DATALOGGER

Model : DL-9602SD

Your purchase of this
SD CARD REAL TIME
DATALOGGER marks a
step forward for you
into the field of
precision measurement.
A l t h o u g h   t h i s
DATALOGGER is a
complex and delicate
instrument, its durable
structure will allow
many years of use if
p r o p e r   o p e r a t i n g
t e c h n i q u e s   a r e
developed. Please read
t h e   f o l l o w i n g
instructions carefully
and always keep this
manual within easy
reach.

       OPERATION MANUAL

Summary of Contents for DL-9602SD

Page 1: ...of precision measurement A l t h o u g h t h i s DATALOGGER is a complex and delicate instrument its durable structure will allow many years of use if p r o p e r o p e r a t i n g t e c h n i q u e...

Page 2: ...tion 6 4 3 Data logger Save the measuring data with time 6 Auto Datalogger Set sampling time 1 second 6 a Start the datalogger 6 b Pause the datalogger 7 Manual Datalogger Set sampling time 0 second 7...

Page 3: ...software after execute datalogger just take away the SD card from the meter and plug in the SD card into the computer it can down load the measured value with the time information year month date hou...

Page 4: ...te hour minute second to the Excel directly user can make the further data or graphic analysis by themselves Circuit Custom one chip of microprocessor LSI circuit Display LCD size 52 mm x 38 mm LCD wi...

Page 5: ...ble USB 01 will get the USB plug Operating 0 to 50 Temperature Operating Less than 85 R H Humidity Power Supply A Alkaline or heavy duty DC 1 5 V battery UM3 AA x 6 PCs or equivalent A DC 9V adapter i...

Page 6: ...ton Button 3 6 Start Pause Button 3 7 Time Button Button 3 8 SET Button 3 9 SD card socket 3 10 Direct input socket 3 11 Isolate input socket 3 12 Reset Button 3 13 DC 9V Power Adapter Input Socket 3...

Page 7: ...the DIRECT input Socket 3 10 Fig 1 of DL 9602SD b For connecting the Isolate RS232 instruments should plug the UPCB 03 to the ISOLATE input Socket 3 11 Fig 1 of DL 9602SD c Should power on the Data S...

Page 8: ...ion it should change the Decimal character at first details of setting the Decimal point refer to Chapter 6 8 page 17 4 3 Data logger Save the measuring data with time information Auto Datalogger Set...

Page 9: ...g text of DATALOGGER per sampling time Manual Datalogger Set sampling time 0 second Set sampling time is to 0 second Press the LOGGER Button 3 4 Fig 1 once the lower position of LCD will show the text...

Page 10: ...ow Remark 1 During the lower LCD show the text DATA please do not take away the SD card from the meter otherwise the SD card may damaged 2 After the text DATA is disappeared then it can take the SD ca...

Page 11: ...DLG01001 XLS After exist the Datalogger then execute again the data will save to the DLG01001 XLS until Data column reach to 30 000 columns then will generate a new file for example DLG01002 XLS 3 Un...

Page 12: ...to normal screen 4 5 To check the channel information The meter can set max 9 channels data input with default The channel No 1 to 9 is depend your meter s character For example Humidity Temp meter I...

Page 13: ...once will turn Off the LCD backlight Press the Backlight ON OFF Button 3 3 Fig 1 once again will turn ON the LCD backlight again 4 7 To check the sampling time It do not execute the Datalogger functio...

Page 14: ...001 XLS DLG01002 XLS from the SD card to the computer The saving data will present into the EXCEL software screen for example as following EXCEL data screens then user can use those EXCEL data to make...

Page 15: ...t Set sampling time Hour Minute Second PoFF Auto power OFF management Light Set LCD backlight ON OFF bEEP Set beeper sound ON OFF dEC Set SD card Decimal character ESC Escape from the advanced setting...

Page 16: ...r all the existing data that already saving into the SD card 6 2 Set the input channel No When the lower display show Input 1 Use the Button 3 5 Fig 1 or Button 3 7 Fig 1 to set the input channel No 1...

Page 17: ...Date Hour Minute Second press the SET Button 3 8 Fig 1 once will save the time value then the screen will jump to Sampling time setting screen Chapter 6 4 Remark After the time value is setting the i...

Page 18: ...3 5 Fig 1 or Button 3 7 Fig 1 to select the upper value to yES or no yES Auto Power Off management will enable no Auto Power Off management will disable 2 After select the upper text to yES or no pres...

Page 19: ...xt to yES or no press the Enter Button 3 4 Fig 1 will save the setting function with default 6 8 Decimal point of SD card setting The numerical data structure of SD card is default used the as the dec...

Page 20: ...er supply The power Button function is disable 8 BATTERY REPLACEMENT 1 When the left corner of LCD display show it is necessary to replace the battery However in spec measurement may still be made for...

Page 21: ...ures will be either following method During the power on use a pin to press the Reset Button 3 12 Fig 1 once a while will rest the circuit system 10 PATENT The meter SD card structure already get pate...

Reviews: