background image

Small:

 

 

Strip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm

2

) wire.

 

Strip insulation 1/2 in (13 mm) for 16 AWG (1.0 mm

2

) or 18 AWG  

(0.75 mm

2

) wire.

 

Use to join one 14 AWG (1.5 mm

2

) supply wire with one 

 

16 AWG (1.0 mm

2

) or 18 AWG (0.75 mm

2

)  control wire.

Large:

 

 

Strip insulation 1/2 in (13 mm) for 10 AWG (6 mm

2

), 

 

12 AWG (2.5 mm

2

), or 14 AWG (1.5 mm

2

) wire.

 

Strip insulation 5/8 in (16 mm) for 16 AWG 

 (1.0 

mm

2

) or 18 AWG (0.75 mm

2

) wire.

 

Use to join one or two 12 AWG (2.5 mm

2

) or 

 

14 AWG (1.5 mm

2

) supply wires with one 

 10 

AWG 

(6 

mm

2

), 12 AWG (2.5 mm

2

), 14 AWG 

 (1.5 

mm

2

), 16 AWG (1.0 mm

2

), or 18 AWG 

 (0.75 

mm

2

) control wire.

Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in China.   10/08 P/N 030-1051 Rev. A

ON

OFF

ON

OFF

ON

OFF

Installation

For installations involving more than one control in a wallbox, refer to Multi-Unit 
Installations before beginning.

ON

OFF

ON

OFF

ON

OFF

Align control and 
tighten screws.

Start screws.

Fan-Speed Controls

 

 

 

No Sides 

1 Side 

2 Sides

Model Number 

Removed 

Removed 

Removed

FS-5F 

5 A 

4 A 

3 A

Removing wallplate and switch.

• Remove wallplate and switch mounting screws.
• Carefully remove switch from wall (do not remove wires).

Verify your application.

Switch must have

 

two insulated wires connected to two screws and a bare copper 

or green wire connected to a green screw. 

Note: 

Do not connect to a light fixture.

Disconnect switch wires.

Backwired:
Insert screwdriver. Pull 
wire out.

Terminal Screws: 
Turn screws to loosen.

OR

Wire the control:

• Connect the green ground wire 

on the control to the green or 
bare copper ground wire in the 
wallbox (see Important Note 3).

• Connect the black wire on the 

control to either of the wires 
removed from the switch.

• Connect the remaining wire on 

the control to the remaining wire 
removed from the switch.

Mount and align control. Install wallplate.

Turn power ON.

Ground

(Bare Copper or Green WIre)

Limited Warranty  

(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)

Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty 
service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299,  postage pre-paid.

THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES,  AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED 
TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, 
OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES 
NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES.

 

LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN 

CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE 
PRICE OF THE UNIT.

 

This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do 
not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty 
may last, so the above limitations may not apply to you. This product may be covered by one or more of the following U.S. 
patents: 4,939,383; 5,191,971 and corresponding foreign patents. Lutron Claro and Fassada are registered trademarks of 
Lutron Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. 

 

© 2008 Lutron Electronics Co., Inc.

Technical Assistance

If you have questions concerning the installation or operation of this product, call the 

Lutron 

Technical Support Center

. Please provide exact model number when calling.

1.800.523.9466 (U.S.A., Canada, and the Caribbean)
Other countries call +1.610.282.3800 
Fax 

+1.610.282.6311 

  Internet: 

www.lutron.com

Important Notes

Please read before installing.

1. CAUTION:

 To avoid overheating and possible damage to other equipment, do not 

use to control receptacles, fluorescent lighting fixtures, or transformer-supplied 
appliances.

2.

 

Set multi-speed fans to their highest setting before installing controls.

3.

 

When no “grounding means” exist within the wallbox then the NEC

®

 2008, Article 

404.9 allows a dimmer without a grounding connection to be installed as a 
replacement, as long as a plastic, noncombustible wallplate is used. For this type 
of installation, cap or remove the green ground wire on the dimmer and use an 
appropriate wallplate such as Lutron’s Claro

®

 or Fassada

®

 series wallplates.

4.

 

Do not use control with a fan and light that operate with the same switch.

5.

 

For new installations, wire a test switch before installing the control.

6.

 

Use FSQ-2F and SFSQ-F controls with a ceiling paddle fan only. Use only one ceiling 
paddle fan per control.

7.

 

Use FS-5F controls only with fans marked "Suitable for use with solid-state fan-
speed controls."

8.

 

Do not wire an FSQ-2F, SFSQ-F or SFSQ-F-HO in a circuit with a GFCI breaker/
receptacle.

9.

 

Controls may feel warm to the touch during normal operation.

10.

  Install in accordance with all national and local electrical codes.

11.

  Clean control with a 

soft damp cloth only

. Do not use any chemical cleaners.

12.

  For indoor use only.

13.

  Controls must be mounted vertically. See stamp on control for correct positioning.

 

Multi-Unit Installations

When combining controls in a wallbox, remove all inner side sections before wiring 
(see below). Use pliers to bend each side section up and down until it breaks off. FS-5F 
controls require reduction of their capacity. Refer to chart below for maximum capacity. 
FSQ-2F, SFSQ-F and SFSQ-F-HO controls do not require capacity reduction.

Important Wiring Information 

Twist wire 
connector tight.

Be sure no bare 
wire is exposed.

When making wire connections, follow the recommended strip lengths and combinations 
for the supplied wire connectors. 

Note: 

Wire connectors provided are suitable

 

for 

copper 

wire only.

 

For aluminum wire, consult an electrician.

Small

 

Large

Green

Black

Ground

Black 

Fan

Black

Black

Ground

Green

Live

Neutral

120 V~
60 Hz

Fan Control

1

2

3

4

5

6

7

English

FS-5F:

  

5 A   

120 V

~

   

60 Hz

 

FSQ-2F:

 

1.5 A   

120 V

~

  

60 Hz

LTFSQ-2H:

 

1.5 A   

120 V

~

   

60 Hz

LTFSQ-FH:

 

1.5 A   

120 V

~

   

60 Hz

SFSQ-F:

 

1.5 A     120 V

~

   

60 Hz

SFSQ-F-HO:

 

2 A   

120 V

~

   

60 Hz

Do Not Remove 
Outside Sections

Inside Sections Are 
Removed From Each 
Control

Side Sections Are 
Removed From Both 
Sides Of Middle Control

Important Note:

Your wall switch may have two wires attached to the same screw (see illustrations below 
for examples). Tape these two wires together before disconnecting. When wiring, connect 
wires to the Dimmer the same way they were connected to the switch.

Lutron Technical Support Center     1.800.523.9466     24 hrs / 7 days 

   

www.lutron.com

WARNING: Turn power OFF at circuit breaker or remove fuse.

• Easy-to-follow 

Instructions

• Instrucciones 

Fáciles de Seguir

• Easy-to-follow 

Instructions

• Instrucciones 

Fáciles de Seguir

P/N 030-1051

P/N 030-1051

Warning: Before proceeding, verify that 
power to the switch is OFF. Otherwise,  
death or serious injury could result.