4-Series
TM
Low-Voltage Rough-In Enclosure
HWI-LV24-120
120 V , 50/60 Hz, 2 A
1
Please Read Before Installing
Installation Instructions
Overview
The
4 Series
Low-voltage Rough-in Enclosure pro-
vides a compact housing for mounting the
4 Series
processor. The enclosure accepts one 120 V feed
to power the processor and its connected keypads.
The enclosure's main feed is self-contained in an
enclosed high-voltage area, eliminating exposure of
high voltage connections when the enclosure cover is
removed for low-voltage wiring. In addition to the
processor, up to 2 contact closure boards (HWI-CCO-
8 or HWI-CCI-8) and/or wire landing boards (HWI-
WLB) may be mounted in the 24 in. (70 cm) enclo-
sure. Contact closure outputs provide low-voltage con-
trol of motors and shades. Contact closure inputs
allow interfacing to photocells, security systems, and
other home systems. The wire landing board is a
wiring aid with three sets of four terminal blocks con-
nected pin-to-pin, simplifying home run wiring.
Important Notes
Codes:
Install in accordance with all local and nation-
al electrical codes.
Note:
Enclosure must be protected by an
appropriately rated (min. 15 A) circuit break-
er, to be supplied and installed in accordance
with local codes by the installer.
Mounting Location:
Power supply will hum slightly
and internal relays will click while in use. Mount in a
location where such noise is acceptable.
Environment:
Ambient operating temperature:
0-40°C, 32-104°F, 0-90% humidity, non-condensing.
Indoor use only.
Cleaning:
To clean, wipe with a clean damp cloth.
DO NOT
use any chemical cleaning solutions.
HWI-LV24-120
Knockout for
RS232 cable
Mounting Diagram
24 in.
(61 cm)
15-1/8 in. (39 cm)
10-3/4 in.
(27 cm)
8 in.
(20 cm)
1-1/2 in.
(38 mm)
1-3/4 in.
(44 mm)
21-1/2 in.
(55 cm)
1-1/2 in.
(38 mm)
Screw
locations for
recess
mounting
5/16 in. dia.
(8 mm)
5/8 in. dia.
(16 mm)
keyholes
Mount
Enclosure
Vertically
Up