Page 1: ...Lux Lux LuxPro Thermostats Mt Laurel NJ NEW MULTI MULTI STAGE STAGE TOUCHSCREENS Features Programming ...

Page 2: ...mable Simple Mode Dual Fuel Capable w optional Outdoor Wireless Remote Temp Transmitter Manual or Auto Humidity and De Humidity Control PSPU732T only Installer Message Energy Watch Calculates Usage and Dollar Amount Screen Lockout Much Much Much More NEW MULTI STAGE TOUCHSCREENS VERY COMPETITIVE PRICING ...

Page 3: ...s a simple non programmable thermostat touch the screen To switch from programmable mode to simple mode remove the faceplate press release the reset button on the bottom right When Touch For Simple Thermostat comes up on the screen touch the screen and the t stat will switch to Simple mode TOUCH FOR SIMPLE THERMOSTAT ...

Page 4: ...tats Mt Laurel NJ Simple Mode puts the thermostat into non programmable mode where only temperature set point cool heat auto mode or fan operation can be changed AUTO FAN AUTO 72F 72 0 46 NEW TOUCHSCREEN FEATURES PROGRAMMING ...

Page 5: ... NJ For Programmable Mode touch the screen Now you can use all of the extensive programmable features to configure the thermostat the way you or the consumer wants it NEW TOUCHSCREEN FEATURES PROGRAMMING TOUCH FOR PROGRAMMABLE THERMOSTAT ...

Page 6: ...outdoor temp if using optional wireless temp transmitter Touch the Screen anywhere to advance to Control Screen Heat Set Point Cool Set Point Outdoor Temp Room Humidity NEW TOUCHSCREEN FEATURES PROGRAMMING With Use of Wireless Remote Transmitter Mode Setting Fan Setting Run Program or Hold Current time date ...

Page 7: ...en button to go back to Home Screen Press MENU to go to Main Programming Screen RUN PROG AUTO FAN AUTO MENU DHUM 68 0 72 0 45 46 70 0 HUMIDITY MANUAL Run Program or Hold Auto or Manual Installers Message Home Screen Current Mode Blinks Main Programming NEW TOUCHSCREEN FEATURES PROGRAMMING Adjust temp and dehumidification settings Fan Auto Fan Intermittent or Fan On Auto Cool Heat Emerg Heat or Off...

Page 8: ...reen allows owner to make adjustments settings and programming choices Push Date Time Settings DATE TIME SETTINGS PROGRAM SETTINGS ENERGY WATCH DEHUMIDIFY ADVANCED SETTINGS VACATION SETTINGS FILTER MONITOR CLEAN SCREEN SET SCREEN NEW TOUCHSCREEN FEATURES PROGRAMMING ...

Page 9: ... Mt Laurel NJ Set date time by pressing each button individually Press MENU to go back to Main Programming Screen NEW TOUCHSCREEN FEATURES PROGRAMMING DATE TIME SETTINGS MENU 12 33 07 20 08 PM 24 12 H M H D Y CLOCK SET TIME DATE ...

Page 10: ...NJ Push Program Settings to set daily temperature and fan settings DATE TIME SETTINGS PROGRAM SETTINGS ENERGY WATCH DEHUMIDIFY ADVANCED SETTINGS VACATION SETTINGS FILTER MONITOR CLEAN SCREEN SET SCREEN NEW TOUCHSCREEN FEATURES PROGRAMMING ...

Page 11: ...f periods per day Each day can be programmed differently Fan can be set differently for each period Each day can be copied to the next NEW TOUCHSCREEN FEATURES PROGRAMMING PROGRAM SETTINGS TU MO WE TH FR SA SU AM 30 07 1 MENU HEAT COOL FAN AUTO EVENT START 68 0 72 0 ...

Page 12: ...py to the next day If YES then you will continue to the following day and be asked the question again etc If NO then you program that day as you wish and proceed on to all the days of the week Press MENU when complete to go back to the Main Programming Screen NEW TOUCHSCREEN FEATURES PROGRAMMING YES NO COPY MONDAY SETTINGS PROGRAM SETTINGS ...

Page 13: ...J Push Energy Watch to see HVAC energy consumption and cost to date DATE TIME SETTINGS PROGRAM SETTINGS ENERGY WATCH DEHUMIDIFY ADVANCED SETTINGS VACATION SETTINGS FILTER MONITOR CLEAN SCREEN SET SCREEN NEW TOUCHSCREEN FEATURES PROGRAMMING ...

Page 14: ...for up to 255 days based on parameters set in Advanced Settings Owner can see energy usage and cost at anytime Hit the RESET button to zero out ENERGY WATCH NEW TOUCHSCREEN FEATURES PROGRAMMING MENU RESET LAST 30 DAYS 150 HRS COMP 20 HRS FURN 120 HRS FAN 290 HRS TOTAL COST 20 30 ...

Page 15: ... for 15 seconds so that you can wash wipe it w o changing any settings CLEAN SCREEN DATE TIME SETTINGS PROGRAM SETTINGS ENERGY WATCH DEHUMIDIFY ADVANCED SETTINGS VACATION SETTINGS FILTER MONITOR CLEAN SCREEN SET SCREEN NEW TOUCHSCREEN FEATURES PROGRAMMING Consult owners manual for maintenance care ...

Page 16: ... Mt Laurel NJ Push Set Screen to change screen settings DATE TIME SETTINGS PROGRAM SETTINGS ENERGY WATCH DEHUMIDIFY ADVANCED SETTINGS VACATION SETTINGS FILTER MONITOR CLEAN SCREEN SET SCREEN NEW TOUCHSCREEN FEATURES PROGRAMMING ...

Page 17: ...an be set to Constant Light or Auto touch the screen Reverse Change from B W to W B Night Reverse Set for Auto screen reverse chgs at 9PM and 6AM NEW TOUCHSCREEN FEATURES PROGRAMMING MENU 07 ON ON AUTO BACKLIGHT REVERSE NIGHT REVERSE CONTRAST SET SCREEN ...

Page 18: ...ation Settings to set parameters for time temperature while away from the home DATE TIME SETTINGS PROGRAM SETTINGS ENERGY WATCH DEHUMIDIFY ADVANCED SETTINGS VACATION SETTINGS FILTER MONITOR CLEAN SCREEN SET SCREEN NEW TOUCHSCREEN FEATURES PROGRAMMING ...

Page 19: ...o Thermostats Mt Laurel NJ Input leave BEGIN date return END date and heat cool temp settings NEW TOUCHSCREEN FEATURES PROGRAMMING VACATION SETTINGS 08 30 09 09 HEAT COOL 20 BEGIN END 65 0 80 0 VACATION SETTINGS 08 ...

Page 20: ...ilter Monitor to see filter usage in days and to reset after changing filter DATE TIME SETTINGS PROGRAM SETTINGS ENERGY WATCH DEHUMIDIFY ADVANCED SETTINGS VACATION SETTINGS FILTER MONITOR CLEAN SCREEN SET SCREEN NEW TOUCHSCREEN FEATURES PROGRAMMING ...

Page 21: ...ts Mt Laurel NJ Filter Monitor Screen shows how many days current filter has been used based on fan run time Reset button will set back to zero NEW TOUCHSCREEN FEATURES PROGRAMMING MENU RESET FILTER USED 15 DAYS FILTER MONITOR ...

Page 22: ...ify mode More detailed settings for humidity control are available in Advanced Settings Installer settings HUMIDITY SETTINGS DATE TIME SETTINGS PROGRAM SETTINGS ENERGY WATCH DEHUMIDIFY ADVANCED SETTINGS VACATION SETTINGS FILTER MONITOR CLEAN SCREEN SET SCREEN NEW TOUCHSCREEN FEATURES PROGRAMMING ...

Page 23: ...en will appear when entering Advanced Settings ADVANCED SETTINGS DATE TIME SETTINGS PROGRAM SETTINGS ENERGY WATCH DEHUMIDIFY ADVANCED SETTINGS VACATION SETTINGS FILTER MONITOR CLEAN SCREEN SET SCREEN NEW TOUCHSCREEN FEATURES PROGRAMMING CAUTION Altering the system properties in the ADVANCED SETTINGS may affect the performance of the HVAC system and should be performed only by a qualified installer...

Page 24: ... On Off Filter Days Energy Usage Parameters Celsius or Fahrenheit Security level Installers message Press FILTER to set Filter Monitor to Off On number of days to monitor NEW TOUCHSCREEN FEATURES PROGRAMMING ADVANCED SETTINGS INSTALL MESSAGE SECU RITY FILTER MENU ENERGY WATCH DAYLIGHT TIME F OFF NEXT PAGE ...

Page 25: ...ermostats Mt Laurel NJ Turn Filter Monitor Off or ON An icon appears on the Home Screen when the Filter monitor is set to ON NEW TOUCHSCREEN FEATURES PROGRAMMING MENU OFF FILTER MONITOR FILTER MONITOR ADVANCED SETTINGS ...

Page 26: ...er Monitor ON screen will then ask for the number of months up to 6 based on fan run time to notify consumer to change filter NEW TOUCHSCREEN FEATURES PROGRAMMING MENU 2 CHANGE FILTER FILTER MONITOR ADVANCED SETTINGS AFTER MONTH Return to Advanced Settings Screen ...

Page 27: ...s Mt Laurel NJ Push Energy Watch to set parameters for tracking HVAC energy usage and cost NEW TOUCHSCREEN FEATURES PROGRAMMING ADVANCED SETTINGS INSTALL MESSAGE SECU RITY FILTER MENU ENERGY WATCH DAYLIGHT TIME F OFF NEXT PAGE ...

Page 28: ...fan and per hr KW cost This allows consumer to watch on going HVAC energy costs by pushing the Energy Watch button on the Main Menu Screen NEW TOUCHSCREEN FEATURES PROGRAMMING MENU 13 1 5 5 COMPRESSOR KW FURNACE KW FAN KW C KWHr ENERGY WATCH ADVANCED SETTINGS Return to Advanced Settings Screen ...

Page 29: ...o Thermostats Mt Laurel NJ Push Security to set level of screen lock preferred NEW TOUCHSCREEN FEATURES PROGRAMMING ADVANCED SETTINGS INSTALL MESSAGE SECU RITY FILTER MENU ENERGY WATCH DAYLIGHT TIME F OFF NEXT PAGE ...

Page 30: ...n to FULL Lock or PARTIAL Lock push OFF button You will be asked for a Pin The default Pin is 1111 To change your Pin push Change Pin and follow the prompts NEW TOUCHSCREEN FEATURES PROGRAMMING MENU OFF SECURITY SECURITY ADVANCED SETTINGS FULL LOCK CHANGE PIN ...

Page 31: ...ARTIAL Lock FULL Lock completely locks out the thermostat from unauthorized use w o the Pin PARTIAL Lock only allows the changing of the temperature setpoint NEW TOUCHSCREEN FEATURES PROGRAMMING MENU OFF SECURITY SECURITY ADVANCED SETTINGS FULL LOCK CHANGE PIN Return to Advanced Settings Screen ...

Page 32: ...s Mt Laurel NJ Push Install Message to input installer message and set frequency of display NEW TOUCHSCREEN FEATURES PROGRAMMING ADVANCED SETTINGS INSTALL MESSAGE SECU RITY FILTER MENU ENERGY WATCH DAYLIGHT TIME F OFF NEXT PAGE ...

Page 33: ...ed to appear on a monthly basis Message can also be accessed by consumer by pushing the icon button on the Control Screen NEW TOUCHSCREEN FEATURES PROGRAMMING INSTALL MESSAGE 1 ABC 3 GHI OK For Service Call ABC Htg at 777 555 4321 ADVANCED SETTINGS MENU 2 DEF 4 JKL 5 MNO 6 PQR 7 STU 8 VWX 9 YZ 0 ...

Page 34: ... Next Page to access Advanced settings for system type cycles rates staging temps dual fuel humidity and more NEW TOUCHSCREEN FEATURES PROGRAMMING ADVANCED SETTINGS INSTALL MESSAGE SECU RITY FILTER MENU ENERGY WATCH DAYLIGHT TIME F OFF NEXT PAGE ...

Page 35: ...rence between Heat Cool set points 1 5 factory settings are recommended NEW TOUCHSCREEN FEATURES PROGRAMMING ON 40 MENU NEXT PAGE PREV PAGE HEAT PUMP 9 ELECTRIC FURNACE HP CUT OFF CUT TEMP CYCLE RATE 3 AUTO CHNGE Heat Pump 2 Stg HP A C No Compressor Electric Furnace Gas Furnace 2 Stg Gas Furn Oil Furnace ADVANCED SETTINGS PUSH NEXT FOR FURTHER SETTING ...

Page 36: ...o ON and setting the CUT TEMP outside the HP will shut down at that CUT TEMP and the gas furnace will take over Press NEXT PAGE for further settings NEW TOUCHSCREEN FEATURES PROGRAMMING ON 36 MENU NEXT PAGE PREV PAGE HEAT PUMP 9 ELECTRIC FURNACE HP CUT OFF CUT TEMP CYCLE RATE 3 AUTO CHNGE ADVANCED SETTINGS DUAL FUEL ...

Page 37: ...urel NJ Allows heat pump to operate with the furnace by changing to the ON position Press NEXT PAGE for further settings NEW TOUCHSCREEN FEATURES PROGRAMMING MENU PREV PAGE HP WHEN NEXT PAGE OFF FURNACE ON ADVANCED SETTINGS DUAL FUEL ...

Page 38: ...start up 3rd Stage Set the reversing valve to energize in Heat or Cool depending on unit design NEW TOUCHSCREEN FEATURES PROGRAMMING MENU COOL 2 2 2 1ST STAGE DIF 2ND STAGE DIF 3RD STAGE DIF OB ENERGIZED NEXT PAGE PREV PAGE PUSH NEXT FOR FURTHER SETTING ADVANCED SETTINGS MULTI STAGE DIFFERENTIAL SETTINGS Consult equipment manufacturer s operation installation manuals before setting these temperatu...

Page 39: ...e compressor run time by bringing on the 2nd stage and full system capacity to meet setpoint NEW TOUCHSCREEN FEATURES PROGRAMMING MENU PREV PAGE IF STAGE 1 RUNS NEXT PAGE 0 TURN ON STAGE 2 ADVANCED SETTINGS MINUTES MULTI STAGE DIFFERENTIAL SETTINGS PUSH NEXT FOR FURTHER SETTING Consult equipment manufacturer s operation installation manuals before setting these temperature settings ...

Page 40: ...hen there is an independent call to humidify When set to OFF fan only runs during heating or cooling cycles De Humidity Fan Same as above NEW TOUCHSCREEN FEATURES PROGRAMMING MENU OFF OFF OFF OFF HUM FAN DH FAN DH REVERSE DHCONTCOMP NEXT PAGE PREV PAGE ADVANCED SETTINGS HUMIDITY CONTROL ...

Page 41: ...closed when relative humidity is above DH set point OFF DH relay is normally open when relative humidity is below DH set point NEW TOUCHSCREEN FEATURES PROGRAMMING MENU OFF OFF OFF OFF HUM FAN DH FAN DH REVERSE DHCONTCOMP NEXT PAGE PREV PAGE ADVANCED SETTINGS HUMIDITY CONTROL ...

Page 42: ...eached whichever comes first both DH relay and compressor will turn off OFF DH relay is independent of compressor activity DH becomes a spare relay and can be used for a variable speed fan or separate dehumidifier or air exchanger NEW TOUCHSCREEN FEATURES PROGRAMMING MENU OFF OFF OFF OFF HUM FAN DH FAN DH REVERSE DHCONTCOMP NEXT PAGE PREV PAGE ADVANCED SETTINGS HUMIDITY CONTROL ...

Page 43: ...mperature or relative humidity if found to be off Temperature accuracy is set at 1 degree It can be adjusted 9 5 Humidity accuracy is 4 It can be adjusted 20 Press NEXT PAGE for further settings NEW TOUCHSCREEN FEATURES PROGRAMMING MENU PREV PAGE HUM 0 ADVANCED SETTINGS TEMP 0 0 ...

Page 44: ...REVERSE feature turned off contact normally open OPTION 1 In Advanced Settings choose DH ControlComp set to ON then lower the temperature to a minimum safe set point then set the desired de humidity level De humidify will control the compressor unless minimum temperature set point is reached whichever comes first NEW TOUCHSCREEN FEATURES PROGRAMMING De humidification options for increasing comfort...

Page 45: ...dify mode Then regardless of temperature the de humidification setting will have priority Caution This method will run the compressor until the de humidification level is reached and may cause overcooling NEW TOUCHSCREEN FEATURES PROGRAMMING De humidification options for increasing comfort and efficiency ...

Page 46: ...e speed fan control set DH REVERSE to control the fan so that low speed is activated to de humidify This method provides maximum comfort while maintaining the temperature in cooling mode NEW TOUCHSCREEN FEATURES PROGRAMMING De humidification options for increasing comfort and efficiency ...

Page 47: ... PSPU7 multi stage touchscreens Used for DUAL FUEL AUTOMATIC HUMIDITY CONTROL of central humidifier NEW TOUCHSCREEN Wireless Remote Temp Transmitter Mounting Bracket Indoor Receiver plugs in at bottom of t stat and mounts under t stat cover Optional Outdoor Wireless Remote Temp Transmitter Kit WTR064 ...

Page 48: ...eceiver into plug located at bottom of PSPU t stat Indoor Receiver Unit installed PSPU Thermostat Screen Push Reset button on Indoor Receiver to initiate communication between Outdoor transmitter and Inside Receiver Plug antenna wire from Indoor Receiver into plug located at bottom right of PSPU t stat ...

Page 49: ...e Valve or Orange Second Stage Furnace RH 24v Heat Transformer Red Y2 Second Heat Pump Unknown and or AC C Common Blue H Humidity Control Unknown DH Dehumidify Control Unknown Variable Fan Control RC 24v Cool Transformer Unknown 11 and 12 Not Used NOTE The above colors are standard in HVAC industry The wiring should be confirmed before installation 12 11 RC DH H C Y2 RH OBW W2 G Y1 ...

Page 50: ...ls please refer to the Instruction or Engineering Manuals or access the LuxPro web site at www luxproproducts com Problems with installation or troubleshooting please call our Technical Support team at 856 234 8803 Ext 7 5 30AM 2PM PST It is best if contractor is on jobsite when calling Tech Support ...

Page 51: ...Lux Lux LuxPro Thermostats Mt Laurel NJ LUXPRO S FULL LINE OF RESIDENTIAL LIGHT COMM L THERMOSTATS OFFER YOU THE BEST VALUE Thanks for viewing our Touchscreen Presentation ...