background image

 

 
 
 

 

Series 3000 

© LYNX Technik AG 

Brunnenweg 3 

64331 Weiterstadt 

Germany 

 www.lynx-technik.com

 

Reference Manual 

P MX 3214 B; P MX 3214 D 

Dual AES Audio Multiplexer 

MiniModule

V 3.1 

Summary of Contents for P MX 3214 B

Page 1: ...Series 3000 LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany www lynx technik com Reference Manual P MX 3214 B P MX 3214 D Dual AES Audio Multiplexer MiniModules V 3 1...

Page 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exce...

Page 3: ...anty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty a...

Page 4: ...ed in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interferen...

Page 5: ...MX 3212 D 11 Power Connections 12 DC Power Connector 12 Installation 13 Mechanical 13 Stand Alone Operation 13 Multiple Units 14 Electrical Installation 15 Stand Alone Operation 15 Multiple Units 16...

Page 6: ...Reference Manual P MX 3214 Version 3 1 Page 6 This Page is intentionally left blank...

Page 7: ...o input Group insertion per embedder is selectable 1 through 4 Four separate SDI outputs of the video with embedded audio are provided Existing audio groups can be overwritten deleted or passed transp...

Page 8: ...setups Any operational parameters configured and stored into the module are recalled when powered up Remote control status monitoring and error reporting is possible when used with the R FR 3010 rack...

Page 9: ...s made through standard 75 Ohm BNC video connections and the balanced audio inputs are made on the Sub D connector P MX 3214 D or the unbalanced audio inputs on BNC connectors P MX 3214 B Module confi...

Page 10: ...Reference Manual P MX 3214 Version 3 1 Page 10 Figure 2 Module Layout...

Page 11: ...le suitable for digital video audio connections to reduce the risk of interference or errors due to excessive cable attenuation Note Due to the compact design of the module it will be necessary to use...

Page 12: ...MiniModule has a captive power lead fitted to the module with a male 5 pin locking bayonet connector This connection provides DC power and also data connectivity to the module Connector wiring is show...

Page 13: ...10 option is required to power each module Please refer to the R FR 3005 Reference Manual supplied with this option for more details b Single Use The MiniModule can be powered independently with the R...

Page 14: ...ack frame option Each module plugs into a connection bus which provides common power for all modules no R PS external power supplies are needed Remote control and status monitoring of all modules is p...

Page 15: ...nnection is solid and locked in place A strain relief is included within the module to prevent excessive strain on the connection Signal connections should be made with care please ensure connections...

Page 16: ...you use the R FR 3005 Rack Frame 1 and or R FR 3010 Rack Frame 2 options Please refer to the documentation supplied with these options for details on electrical installation Settings and Control The...

Page 17: ...switch settings are necessary A single Service Adapter can be used for all MiniModules SWITCH Position Set Function ON Local Adjustment Enabled 1 OFF Local Adjustment Disabled ON 24 bit AES output 2...

Page 18: ...n the dip switches may not reflect the actual configuration stored in the module This is because all settings can be changed from the remote control system or via the Service Adapter This overrides th...

Page 19: ...sample rate converted to 48 KHz input range 30KHz to 48KHz When set to OFF the sample rate conversion will be bypassed If bypassed all incoming audio must be synchronous to the input SDI signal This i...

Page 20: ...operation 1 ON Local adjustments enabled 2 OFF 20 bit AES 3 OFF Only replace audio group selected 4 OFF Sample rate conversion bypassed 5 ON Audio Group 1 Selected Embedder 1 OFF Embedder 2 6 OFF Embe...

Page 21: ...ough the access holes figures 2 or 3 One LED is provided for the audio signals and one for indication of the SDI status Both LEDs are three color and have several indication states LED COLOR INDICATIO...

Page 22: ...ion in installations where visible access to the bottom of the module is not convenient This LED is three color and has several indication states N o t e LED OFF indicates power is lost or there is a...

Page 23: ...selected on the control system there is a locate button on the top of the GUI Locate Function in Control System When Locate is selected the status indicator on the GUI and the module LED s will flash...

Page 24: ...ectable groups in the SDI input stream Input Lost Module generates own SDI signal for embedding Delete Delete all selected audio groups Performance AES input sample rate 48 KHz synchronous or 30 KHz 4...

Page 25: ...bracket for 4 MiniModules Can be mounted with screws on any surface R FR 3005 Rack Frame 1 This is a basic 19 inch rack mountable frame which can accommodate 10 MiniModules with power bricks R PS 1 or...

Page 26: ...l AES Multiplexer Model Number P MX 3214 2 D Part Number 4 155 013 214 Service If you are experiencing problems or have questions concerning your P MX 3214 MiniModule please contact your local distrib...

Page 27: ...Reference Manual P MX 3214 Version3 1 Page 27...

Page 28: ...X Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik manu...

Page 29: ...Reference Manual P MX 3214 Version3 1 Page 29 This Page is intentionally left blank...

Page 30: ...Reference Manual P MX 3214 Version 3 1 Page 30 Notes...

Reviews: