background image

LZR

®

- FLATSCAN SL

surface

PL

EA

SE K

EE

P F

O

R F

U

R

TH

ER U

SE - D

ES

IG

N

ED F

O

R C

O

LO

U

R P

R

IN

TI

N

G

EN

User’s Guide for product version 

0100

 and higher

See product label for serial number

COMPACT LASER SCANNER FOR SLIDING DOOR

Summary of Contents for FLATSCAN SL

Page 1: ...FLATSCAN SLsurface PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOUR PRINTING EN User s Guide for product version 0100 and higher See product label for serial number COMPACT LASER SCANNER FOR SLIDING D...

Page 2: ...tion 7 DIP switch 8 Power cable DESCRIPTION Caution Laser radiation Remote control sequence Possible remote control adjustments Factory values Attention Note The LZR FLATSCAN SLsurface is a multi func...

Page 3: ...t a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The sensor manufacturer cannot be he...

Page 4: ...DIP switch the orange LED flashes A LONG push on the push button confirms the settings active high JFS active low normal ON OFF Place the template onto the suitable position Drill 2 screw holes and 1...

Page 5: ...E SPOTS ADJUSTMENTS SETTINGS Quickly press the push button twice to activate the visible spots they will help you position the curtain Quickly double click to activate or deactivate the visible laser...

Page 6: ...he left right limit of the detection field The LED flashes red while calculating 3 Wait until the sensor flashes green again Stretch out your arm in front of you and make an up and down movement to de...

Page 7: ...NFIGURATION NO normally open NC normally closed NO POWER NO DETECTION DETECTION In order to change these settings by remote control adjust DIP switch 4 to ON The LED turns green if there is a detectio...

Page 8: ...e sensor can be adjusted with the remote control If the red LED flashes quickly after unlocking you need to enter an access code from 1 to 4 digits If you do not know the access code cut and restore t...

Page 9: ...ield of 1cm TEACH IN turn on off the visible spots factory reset of all values factory reset of all values except field dimensions output redirection and configuration disable the output and LED for 1...

Page 10: ...Launch a new safety field teach in Unwanted detections due to environment or external conditions 1 Make sure the laser curtain at the correct position 2 Verify if the laser window is dirty and clean i...

Page 11: ...ose to the sensor is masking part of the detection field 1 Make sure the laser window is not scratched If it is replace sensor 2 Remove all masking elements insects spider web flexible tube laser wind...

Page 12: ...y free Max switching voltage 42V AC 60V DC Max switching current 100 mA 1 Relay free of potential change over contact Max contact voltage 60V AC 125V DC Max contact current 1 0A resistive Max switchin...

Reviews: