-. . ./ /01 -. . ./

 

 

 

USER INSTRUCTIONS 

ENGLISH   

 

 

 

 

            EP 8050 HU 

ePass operates with a numeric six-digit code or a word with 6 letters.  Up to nine secondary 

codes can be added (see next page).  Each key press is confirmed with an audible and light 

signal.  

After entry of a valid code a double signal follows. An invalid entry is followed by a long signal.  

After 10 seconds without entry, an already started code entry is cancelled. 

 

Enter code (factory code = 1-2-3-4-5-6), turn knob and open. If not opened within 3 seconds, 

ePass secures automatically. 

Locking: 

Close door and turn knob fully to closing position. The lock is secured.  

Manipulation protection: 

Entry of four consecutive invalid codes – keypad is blocked for 5 minutes. During this period, the light 

flashes every 10 seconds and any key press causes a long signal.  After expiration, entry of two more 

invalid codes restarts the 5 minute blocking period. 

 

A series of signals during opening indicates that the battery is weak 

and must be replaced.   

 

To insert a battery, loosen the screw (if present) and 

slide the cap off the unit as shown on the left.  

Remove used battery and connect one (1) fresh 

battery to the battery clip. Only use fresh 9V-

ALKALINE batteries from brand name manufacturers 

like DURACELL

TM

.  Align cap in the little track of the 

housing and slide back on.  Be careful not to pinch the 

battery cable.  

 

Please recycle the old Battery 

 

 

 

 

With the main code, up to nine additional opening codes can be added or deleted.  The 

opening codes are numbered from position one [1] to position nine [9].   To easily keep 

track of which positions are used, it is suggested to fill out the table below.  You can also 

check on the ePass which positions are occupied. 

All codes can be changed by the different users themselves (see page 1). 

All codes must be different. Code length is always six digits. 

Press and hold

 Key [1] until double signal.  The light remains on during the following 

actions.  

• 

Enter main code. 

• 

Enter selected position [1]-[9]  (Double signal if position free) 

• 

Enter new opening code twice (Double signal after each) 

In case of an entry error, wait 10 seconds and begin again. 

Press and hold

 Key [3] until double signal.  The light remains on during the following 

action.  

• 

Enter main code. 

• 

Enter selected position [1]-[9]  (Double signal indicates position deleted) 

Long signal indicates position was unoccupied. 

Press and hold

 Key [7] until double signal.  The light remains on during the following 

actions.  

• 

Enter main code. 

• 

Enter keys [1] to [9].   

Long signal = Position unoccupied 

Double signal = Position occupied 

Write down here to whom you gave an opening code 

POS  DATE 

NAME 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GENERAL 

Open:  

Change code: (with door open) 

Press and hold

 Key [0] until double signal. The light remains on during the following actions.  

· Enter old code (double signal) 

· Enter new code (double signal) and repeat new code (double signal) 

In case of entry errors (long signal), the old code remains valid.  

Current supply / battery change: 

Managing the Codes: 

Adding an Opening Code:  

Deleting an Opening Code: 

Check Positions: 

Position Table: 