background image

R7E-YV2

P. 1 / 6

EM-7807-D Rev.4

DC VOLTAGE OUTPUT MODULE, 2 points

(Ethernet Modbus/TCP)

MODEL

R7E-YV2

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

DC voltage output module ..................................................(1)

 

MODEL NO.

Confirm that the model number described on the product is
exactly what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.

POINTS OF CAUTION

 

CONFORMITY WITH EU DIRECTIVES

• The actual installation environments such as panel con-

figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrat-
ed in a panel system.  The user may have to review the CE 
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and

confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 115mA

 

GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the power 

supply and output signal for safety.

 

ENVIRONMENT

• Indoor use
• When heavy dust or metal particles are present in the

air, install the unit inside proper housing with sufficient
ventilation.

• Do not install the unit where it is subjected to continuous

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C

(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive

cable, high frequency line, etc.).

• Do not bind these cables together with those in which

noises are present.  Do not install them in the same duct.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.

COMPONENT IDENTIFICATION

Output Terminals

Status Indicator LED

Operating Mode Setting DIP SW (SW1)

PC Configurator Jack

Power Supply Terminals

RJ-45 Connector

SIDE VIEW

FRONT VIEW

CNFG.

1

2

3

4

5

6

7

8

6

7

8

9

2

3

4

1

10

5

LINK

COL

RUN

LINK100

PWR

4

5

6

7

1

2

3

056 222 38 18

mailbox@sentronic.com

www.sentronic.com

SENTRONIC

AG

Summary of Contents for R7E-YV2

Page 1: ...and confirm its operational range as indicated below 24V DC rating 24V 10 approx 115mA GENERAL PRECAUTIONS Before you remove the unit or mount it turn off the power supply and output signal for safety ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air install the unit inside proper housing with sufficient ventilation Do not install the unit where it is subjected to co...

Page 2: ... ON ON OFF 0 1V DC ON ON ON OFF 0 5 0 5V DC ON ON ON ON PC Configurator setting Caution SW1 3 is unused Be sure to turn off unused one POWER SUPPLY TERMINAL ASSIGNMENT 4 NC 5 NC 6 24V 1 NC 2 NC 3 FG 7 0V NO ID FUNCTION NOTES 1 NC 2 NC 3 FG FG 4 NC 5 NC 6 24V Power input 24V DC 7 0V Power input 0V OUTPUT TERMINAL ASSIGNMENT 6 NC 7 VH0 8 VL0 1 NC 2 COM0 3 COM0 9 VH1 4 COM1 10 VL1 5 COM1 NO ID FUNCTI...

Page 3: ...IDE SPAN VOLTAGE VHn VLn COMn NARROW SPAN VOLTAGE 7 VH0 8 VL0 2 COM0 3 COM0 OUTPUT 0 9 VH1 10 VL1 4 COM1 5 COM1 OUTPUT 1 7 6 0V 24V DC 3 FG Modbus TCP RJ 45 CONNECTOR EXTENSION CONNECTOR OUTPUT RANGE Wide span voltage 10 10V DC 5 5V DC 0 10V DC 0 5V DC 1 5V DC Narrow span voltage 1 1V DC 0 1V DC 0 5 0 5V DC WIRING INSTRUCTIONS SCREW TERMINAL Torque 0 5 N m SOLDERLESS TERMINAL mm inch Refer to the ...

Page 4: ...from bytes 32 time 10ms TTL 64 Reply from bytes 32 time 10ms TTL 64 Reply from bytes 32 time 10ms TTL 64 Ping statistics for Packets Sent 4 Received 4 Lost 0 0 loss Replies in case of normal connection are as shown above If the connection cannot be established normally due to e g wrong IP address other replies such as timeout will be received CHECK CONNECTION TO THE APPLICATION SOFTWARE Check Poin...

Page 5: ... bytes 13 Program Controller 14 Poll Controller 15 Force Multiple Coils X Digital output from the slave read write 16 Preset Multiple Registers X General purpose register within the slave read write 17 Report Slave ID X Slave type RUN status 18 Program 884 M84 19 Reset Comm Link 20 Read General Reference 21 Write General Reference 22 Mask Write 4X Register 23 Read Write 4X Register 24 Read FIFO Qu...

Page 6: ...d I Integer 1500 11500 15 115 F Floating Note DO NOT access addresses other than mentioned above Such access may cause problems such as inadequate operation STATUS Analog input modules models R7E SV4 R7E TS4 R7E RS4 R7E MS4 R7E CT4E can show input status of each channel Analog output modules models R7E YS2 R7E YV2 and discrete I O modules models R7E DA16 R7E DC16A R7E DC16B shows 0 at the same add...