background image

MORE INFORMATION

THESE SPECIFICATIONS

ARE AVAILABLE ON 3.5"

PC & MAC FORMAT DISK IN

POPULAR WORD

PROCESSOR FORMATS

CALL 800/258-6883

FAX 425/487-4337

OUTSIDE THE U.S., CALL

425/487-4333

2/6/98

METER BRIDGE • CONSOLE STAND

METER BRIDGE

1. GENERAL
CONFIGURATION.

 The

Mackie 8•Bus Meter Bridge
shall be provided as a user-
installable display option for
the Mackie 8•Bus Series
Consoles and shall include
mounting hardware, inter-
face cabling and instruc-
tions. The Meter Bridge
frame shall be formed of
painted steel, and a model
shall be available to fit each
of the four 8•Bus Console
configuration options.

2. MECHANICAL SPECIFI-
CATIONS.

 The Meter Bridge

frame shall have a display
face 3.20" in height, and
shall have a width of 45.80"
(

MB

32

), 37.00" (

MB•24

), or

29.15" (

MB

16

 and 

MB

E

).

At each end of each Meter
Bridge frame shall be a
mounting ear designed to
accommodate mounting
and rotation on the appro-
priate Mackie 8•Bus Console
by means of collar pieces
and associated hardware.
Each Meter Bridge frame
shall accommodate 32
(

MB

32

), 24 (

MB

24

) and

(

MB

E

), or 16 (

MB

16

) LED

ladder-type meters. Addition-
ally, the 

MB

32

MB

24 

and

MB

16

 shall be fitted with

two 3" mechanical VU
meters. The Meter Bridge
shall have 5 (

MB

32

), 4

(

MB

24

), or 3 (

MB

16

) and

(

MB

E

) access slots for

interface connections.

3. DISPLAY.

 The Meter

Bridge shall have a peak-
reading LED ladder-type
meter for each of the
Console input/tape chan-
nels, and the 

MB

32

,

MB

24 

and 

MB

16

 shall

have two additional me-
chanical VU meters for the
Console main outputs. All
the display meters in the
Meter Bridge shall be
electronically buffered. The
LED meters shall have 12
segments, displaying a
range of –40 dB to +10 dB.
The 0 dB reference level for
the LED meters shall be
4 dBu. The VU
meters shall be calibrated
to read 0 VU for a level of
+4dBu measured at the
Console main outputs.

4. INTERFACE CABLING.

Depending on the model,
the Meter Bridge shall have
3, 4 or 5 ribbon-type inter-
face cables, each positioned
and terminated in a manner
to easily connect to the
corresponding interface
sockets on the Mackie 8•Bus
Console frame.

5. POWERING. 

All powering

for the Meter Bridge will be
provided by the Mackie
8•Bus Console through the
interface ribbon cables.

6. LED LADDER METER
INPUT SWITCHING.

 The

Meter Bridge shall have a

two-position switch which
shall globally switch all the
LED meters to one of two
sources available from the
Console: the multitrack tape
return or the channel direct
output.

7. INSTRUCTIONS.

 The

Meter Bridge shall include
complete, illustrated and
user-friendly assembly
instructions, which shall
conform to existing Mackie
standards for technical
literature without being
actually misleading.

8. DESIGNATION.

 The Meter

Bridges shall be designated
according to size and con-

®

Reviews: