background image

 

Doc No. 993068                                                                                                                                                                                                             Revision of document: A                               
  

Revision Date: 25.05.21 

 
 

   

 

 
 

 
 
 

 
 
 
 

 

 

 
 

M180 Mobile Hoist 

Pre Sales Document 

This document includes Fixed and Folding variants 

Summary of Contents for M180

Page 1: ...Doc No 993068 Revision of document A Revision Date 25 05 21 M180 Mobile Hoist Pre Sales Document This document includes Fixed and Folding variants...

Page 2: ...aching QRS Quick Release System Carry Bar 6 Attaching detaching the Battery 7 Folding the Hoist 7 Technical Specification 8 Mackworth M180 Dimensions 8 Specifications 9 Electrical specifications 9 Env...

Page 3: ...m while reviewing this manual The functions of raising and lowering the boom are accomplished by pressing buttons on the hand control The opening and closing of the legs on the Mobile Hoist are of man...

Page 4: ...ng locking mechanism lift the loop out of the hook and release the locking mechanism The same process of attaching and detaching the Sling is relevant for the QRS Quick Release System Carry Bar Compat...

Page 5: ...Ability Sling Range Product Material and Code CA300 Universal CA400 Universal Deluxe CA500 Toilet Access CA501 Toilet Access with crossover straps CA502 Toilet Access with head support CA503 Toilet Ac...

Page 6: ...the locking mechanism into the hook by pressing down on the tab Figure 8 and 9 2 With the carry bar positioned sideways along the length of the bar move the pin at the top of the carry bar into the ho...

Page 7: ...If you have obtained the Folding mast version of the Mackworth M180 the procedure below will instruct on how to safely and effectively fold the M180 Hoist Follow the procedure below in reverse to unf...

Page 8: ...993068 Revision A P a g e 8 of 12 Technical Specification Mackworth M180 Dimensions All dimensions below are shown in millimetres Figure 20 Figure 21...

Page 9: ...al Leg Lever with 0kg 80 N Electrical specifications Battery type 2 x 12 volt Rechargeable sealed lead acid Battery capacity 24 V DC 1 x 2 9 Ah Charger rated input 230VAC 50 60Hz Charger rated output...

Page 10: ...void To ensure the safety and continued good function of your Hoist routine service must be performed on your Mackworth M180 Mobile Hoist Service should be completed by a Prism Medical UK approved ser...

Page 11: ...he cleaning process Application is through a clean damp cloth applied to wipe the device down Use in the following dilutions to ensure an effective clean Actichlor dissolvable chlorine tablets provide...

Page 12: ...for any errors or omissions Prism Medical UK operates a policy of continuous improvement Specifications and other data are subject to change without notice Manufacturer contact details Prism Medical...