DS100-1  May ’07 

www.rfsolutions.co.uk

 

©

2007 REG No 277 4001, ENGLAND.

 

GSM & GPRS Modem

 

 

 

 

GSM and GPRS 

 

Voice / Fax / SMS and Data  

 

Quad Band 850 / 900 / 1800 1900 MHz 

 

Accepts Standard SIM Card 

 

Miniature size 88 x 60 x 26mm 

 

Can Be Used On Standard GSM Network 

 

RS232 Interface 

 

One user programmable input/Output Port 

 

GSM100T: TCP/IP stack available for data and 

internet 

 

AT command set:  

GSM 07.05 and 07.07 and WAVECOM 

 

GPRS Class B Class 10:  

36Kbps download / 24Kbps upload 

 

Compact "Plug And Play" Quad band GSM modems can be directly connected to the serial port of a desktop or 

notebook computer through the RS232 interface. A standard SIM card can be inserted in the integral card-holder 

within the metal enclosure. 

 

The modems’ metal casing makes it an appropriate solution for tough industrial applications such as Telemetry, 

Wireless Local Loop (payphones) or as part of a fleet management system.  The small size makes it simple to 

integrate in a space constraint environment. The modem is supplied with power cable. Other accessories available 

are an antenna (with 1m coax cable), RS232 connecting cable with Telephone interface, DIN Rail mounting adaptor 

and power supply unit.

  

 

About GPRS:  

GPRS stands for General Packet Radio Services. The user can remain "ON" all the time and the 

data communication speed rivals that of a cable modem.

 

 

Ordering Information  

Part No 

Description 

GSM100 

GSM Quad Band Modem, GPRS Class 10 

GSM100T 

As GSM100 with Additional TCP/IP Stack  

GSM20-ANT 

Antenna with flying lead and connector 

GSM20-CAB232 

RS232 Cable Interface to PC 

GSM20-DINRL 

DIN Rail Mount Bracket 

GSM20-PSU 

Power Supply  (12Vdc to 110-240Vac) 

Summary of Contents for GSM100

Page 1: ...ms metal casing makes it an appropriate solution for tough industrial applications such as Telemetry Wireless Local Loop payphones or as part of a fleet management system The small size makes it simpl...

Page 2: ...7 REG No 277 4001 ENGLAND Page 1 GSM GPRS Modem CONTENTS SAFETY PRECUTIONS 2 CHAPTER 1 INTRODUCTION 3 CHAPTER 2 INSTALLATION 7 CHAPTER 3 WORKING WITH MAESTRO 100 9 CHAPTER 4 SPECIFICATION 12 CHAPTER 5...

Page 3: ...thorizing the use of GSM in vehicle in your country before installing the modem z Install the modem by qualified personnel Consult your vehicle dealer for any possible interference of electronic parts...

Page 4: ...e the following 1 Maestro 100 or 100T x 1 2 Power cord with fuse x 1 3 Safety note x 1 1 2 Interfaces 1 2 1 Status indicator The LED will indicate different status of the modem off Modem switched off...

Page 5: ...to Send Input 13 RI Ring Indicator Output 14 RESET Input Pull low to reset 15 SPEAKER Output Specification of microphone and speaker to be connected Parameters Min Typical Max Remark Microphone curre...

Page 6: ...t LOW voltage 0 0 5V Triggered by pulling this pin to LOW level otherwise leave it open Please refers to Chapter 6 Appendix for using I O and INTR signals Contact your dealer if you need wire for the...

Page 7: ...D 9 female Plug 4P4C 1 1 2 3 3 4 1 5 4 6 2 7 6 8 4 9 5 10 2 11 8 12 7 13 9 14 15 3 Sub D 9 pin Y cable Direct connection with standard 9 pin RS 232 port DTE Direct connection with common handset of t...

Page 8: ...ttle Then take out the SIM holder Note DO NOT pull out the SIM holder without pushing the eject button Put the SIM card to the tray make sure it has completely sit on the tray Put the tray back into t...

Page 9: ...nnect the open ending of the included power cord to a DC supply Refer to the following for power supply requirement Input voltage range 5V 32V Rated current 650 mA Connect the connector to the modem T...

Page 10: ...ing the modem using Microsoft Windows XP HyperTerminal as example 3 1 1 On the first time power up you can use a terminal software to communicate with the modem through an RS 232 serial port Following...

Page 11: ...G No 277 4001 ENGLAND Page 10 GSM GPRS Modem 3 1 3 Choose the correct Com port and baud rate settings 9600bps for Eco 115200bps for others 8bits no parity bit 1 stop bit 3 1 4 On the terminal screen t...

Page 12: ...20 0 The first parameter has to be at least 15 for normal communication RING An incoming call is waiting ATA Answer the call Receiving an incoming call OK ATD1234567 Don t forget the at the end for v...

Page 13: ...ge range 5V 32V Rated current 650 mA Typical current consumption 5V 12V 32V GSM850 communication mode PCL5 310mA 130mA 50mA EGSM900 communication mode PCL5 310mA 130mA 50mA DCS1800 communication mode...

Page 14: ...0 1 0 0 New message indication Note settings stored in SIM not in modem 5 2Input Output port This port can be configured as either an input one or an output one To configure it as an input port first...

Page 15: ...nnected properly to the modem Check if the network coverage is available 6 3 The modem does not response to the terminal program Check if the RS 232 cable has been connected properly Check if your pro...