background image

Summary of Contents for C-2000

Page 1: ...UAL Document Number 481618 Original Release September 16 1994 Rev B August 9 2000 Copyright 1994 1996 2000 Raytheon Company All Rights Reserved Reproductionof all or parts of this documentby MagnaStarDealers for use in sales installation or maintenanceof MagnaStarproducts is authorized ...

Page 2: ...T WITH MAGNASTAR MAINTENANCE TERMINAL MMT 6 1 Introduction 6 2 Test EquipmentRequirements 6 3 C 2000 InstallationCheck Outwith MMT 7 0 Programming The MagnaStar System 7 1 Handset Configuration Screens 7 2 MagnaStarAircraft ConfigurationSettings Sheet 8 0 MAGNASTARMAINTENANCETERMINAL MMT SOFTWARELOADING 9 0 TROUBLESHOOTINGPROCEDURES 9 1 TroubleshootingProcedurefor MMTITutorial 9 2 Additional MMTI ...

Page 3: ...tlePage 4 18 95 4 18 95 1 1thru 1 4 1 0 Introduction 2 0 4 18 95 2 1 Technical Characteristics 4 18 95 8 1 8 0 MMT SoftwareLoading 4 18 95 Title 8 b 2 20 2 22 2 23 2 33 Appendix B Rev F of ICD 7 17 96 Complete Document Completedocument revised Total replacement of original document Entire Document 8 9 2000 Entire Document Complete Document Complete document revised Total replacement of orioinaJ do...

Page 4: ...tion link to callers from any cabin handset The C 2000 supports both analog interfaces and the digital CEPT EI interface to multi channel SATCOM systems Cabin Management MagnaStarair ground communicationscan be provided to aircraft using Connection separatelysupplied cabin managementsystems Contact MagnaStarengineering support on the StarLine at 888 246 STAR for further infonnation and specific in...

Page 5: ...ment The RJ II jacks are integral to the handset they may be remoted so that the fax modem cable doesnot interfere with useof the handset The systemis designedto support high quality low error rate voice band data transmissions at 2400 bps 4800 bps and 9600 bps Higher rate capabilities are in developmentby RaytheonandGTE Airfone engineering TOO Customersupplied TOO equipmentis supportedby the Magn...

Page 6: ...o the LAN bus The CDBR 2 model 2 provides two analog interface connections each of which can support either a four wire analog handset or two wire data for direct connection of a fax machine or modem Additionally the CDBR 2 provides a separateinterface for connectionof a digital handset Di2ital Handset The telephonehandsetshavebeenselectedfor performance and reliability The handsets contain noise ...

Page 7: ... when one or more particular handsetsarein use Miscellaneous The MagnaStarsystemcan interfaceto many other communications equipment The 802 modification to the ARTU provides a CEPT EI interface to connect directly to SATCOM systems or to cabin managementequipment The flexibility is built in to the system to accommodatecustomer unique requirementswith minimum new development 1 3 Installation Summar...

Page 8: ...3 0 2 0 9 0 3 0 6 0 2 0 9 0 34 0 2 0 3 1 3 ARTU MountingTray Antenna Duplexer Handset typ CDBR I CDBR 2 AIU CAS CHIP CPI 15 4Ibs 3 1 0 5 2 0 0 6 1 3 0 4 2 0 0 75 0 4 0 7 2 8 Power Transmit Nominal 2phones Maximum Receive Nominal 212 Watts 7 7 A at 27 5 Vdc 265 Watts 9 6 A at 27 5 Vdc 120Watts 4 4 A at 27 5 Vdc Voltage Range 20 5 to 32 5 Vdc 00 16OC Category B Environmental Tested per00 16OC Temper...

Page 9: ...0 on CI 0 QZ f Ie u u ii5 u V V u N CJ f u f u u u oJ U N 3 0 t a on t on on I onO uO u u 0 V u u 3 3 u s u N U u u I 0 J Q J 0 it g co 8 8 u 8 N N 5 u u Q U 0 r oJ CJ N rn j U u 3 u N u CJ u Q U u 3 u u N U N 3 u 3 N u c 0 II k u 5 u N u N j U u u u u u N 5 u oJ u VI on 0 r u 3 u CD u N CI1 j U N c o u u rI a 3 rrc E E N 1 1 UU Q 1 u u 5 s i i j 1 C s B C 3 g i f 8 to u 0 f 0 u Q v i a u i 1 f a ...

Page 10: ...ONE SYSTEM Flammability All materialsusedin the construction of the MagnaStar systemmeetthe flammabilityrequirements of at leastclassVI ofUL 94 orhasbeentested pertherequirements of FAR25 853appendix F PMA For FAA PMA applicability seeRaytheonDocument 481571 2 3 RevS ...

Page 11: ...IU CDBR I andCDBR 2 areshippedwith connectorkits Theseconnectorkits are containedwithin the unit shipping package The connectorkits provide most of the connectorsrequired to interfacetheseunits to other devices Refer to section3 3 of the Interface Control Document ICD in Appendix B of the MagnaStar Installation Manual for a list of connector kit parts The connectorkits are also accompaniedby a con...

Page 12: ...les should then be checked for proper interconnection The required check list is SIGNAL CABLE INSTALLATION CHECK LIST a Visually inspectcablesfor bent or damagedconnectorpins b Visually inspectfor proper back shell installation c Continuitycheck for proper pin to pininterconnectionbetweencable connectors d Checkfor open circuit condition betweeneach pin and the back shell e Checkfor opencircuit co...

Page 13: ...tor pins RJ 11 Cables Prior to installationof a FAX or Modemto a Handset check the RJ 11cablefor proper interconnection A required checklist for this cableis a Visually inspectcable for bent or damaged pins b Continuitycheck for properpin to pin interconnectionbetweencable connectors c Checkfor open circuitcondition betweeneach pin and all other connector pins MagnaStar Maintenance Terminal MMT Ca...

Page 14: ... the ground The MagnaStarantennashould not be located in positionthat will be blocked by other mechanicaldevices in close proximityor easily shadowedwhen the aircraft maneuversduring flight 5 1 2 DUPLEXER a After installingthe duplexer measurethe DC resistancebetweenthe duplexerand the airframe Bondingresistancemust be less than 2 5 milliohms b Check the antennacable transmit cable and receivecabl...

Page 15: ...f the ARTU e Verify that there are no airflow restrictionsat the top of the ARTU f Verify that the Receivecoaxialcable is connectedfrom the Receiveport RCV J4 of the ARTU to the Receive port RCV J3 of the Duplexer g Verify that the Transmit coaxialcable is connectedfrom the Transmit port XMT J5 of the ARTU to the Transmit port XMT J1 of the Duplexer 5 2 RevS ...

Reviews: