background image

1/3

LH71 Change of display resolution (polarity)

Press 

key of the axis you want to change and select 

the  measurement unit resolution.

When you have made your selection, press       

key to save your settings.

Press               key two or three times while the display is                            .

The display will be 

(measurement unit resolution).

Press           key to check the current length measurement unit resolution.

Press                key once while the display is                            .

The display will be                             (measurement unit resolution).

Press           key to check the current measurement unit resolution.

LH71 Change of display resolution (polarity)

Ver.1 (2021.1) CS&S

* If you do not know the output resolution of the measurement unit, refer to the separate "Initial setup manual".

About 2 sec

For LH71-1, LH71-2

For LH71-3

Press 

key once to automatically switch to advanced settings mode.

The display will be 

.

Press 

key, the display becomes the normal display.

Display of measurement unit resolution (LH71-3)

Purpose of change

Operation

Explanation

Change the measurement unit resolution

Change the length measurement unit resolution in 
the basic settings. And check the display resolution 
in the detailed settings.

Change the polarity for each input axis 
while using the addition function

Change the selection of addition display in the basic 
settings

Change the display resolution

Change the display resolution in the detailed 
settings 

Change the display polarity
(Counting direction is reversed)

Change the display resolution in the detailed 
settings 

Diameter display (double count value)

Change to diameter display with display resolution 
in the detailed settings 

Detailed settings 

Display resolution 

Change

Detailed settings 

Display resolution 

Diameter display

LH71-3

The operation method for changing the display resolution differs depending on the purpose and conditions of the change. 
Select the purpose and conditions to be changed from the table below and perform the operation.

Basic setting 

Measurement unit resolution 

Change

Basic settings 

Addition display 

Change

Detailed settings 

Display resolution 

Change polarity

Standard

Expansion

Extended key

Selection of measurement 

unit resolution

Set to basic setting mode.

Turn                key  “ON” while the AC adapter is energized.

Press and hold                 key for 3 seconds after the lamp changes from blinking to off.

Basic setting 

Measurement unit resolution 

Change

About 2 sec

Switch from basic settings to normal count mode.

Press 

key once and the display will change to 

.

Press 

key once and the display will change to

.

Input 1

Input 2

Input 3

Power ON