background image

 

 

Manual Part Number:  99875342-1

 
 
 
 
 
 
 

EXCELLA STX 

MICR CHECK READER 

AND DUAL-SIDED SCANNER 

INSTALLATION AND OPERATION MANUAL 

 
 
 

 

 
 
 
 

MARCH 2006 

 

 

 
 

  

 

REGISTERED TO ISO 9001:2000 

Phone:  (562) 546-6400 

Technical Support: (651) 415-6800 

www.magtek.com 

1710 Apollo Court 

Seal Beach, CA 90740 

FAX:  (562) 546-6301 

Summary of Contents for EXCELLA STX

Page 1: ...STX MICR CHECK READER AND DUAL SIDED SCANNER INSTALLATION AND OPERATION MANUAL MARCH 2006 REGISTERED TO ISO 9001 2000 Phone 562 546 6400 Technical Support 651 415 6800 www magtek com 1710 Apollo Court...

Page 2: ...is a trademark of MagTek Inc REVISIONS Rev Number yright 2004 20 MagTek Inc Printed in the United States of America Information in this document is subject to change without notice No part of this do...

Page 3: ...treated by customers Service may be obtained by delivering the product during the warranty period to MagTek 1710 Apollo Court Seal Beach CA 90740 If this product is delivered by mail or by an equivale...

Page 4: ...Class A digital device pursu to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment...

Page 5: ...NANCE 13 POWER UP 13 ERATION 13 Check Insertion 13 ID Card Insertion 14 LED Locations and Descriptions 14 INTENANCE 16 Printer Cartridge Cleaning 16 Scan Bar Cleaning 17 Card and Check Path Cleaning 1...

Page 6: ...vi APPENDIX D LICENSE AND COPYRIGHT 37 3 Amount Field 36 4 Auxiliary On Us Field 36...

Page 7: ...tion for Holding and Entering ID Card 14 Figure3 3 MSR Card Insertion 14 Figure 3 4 Location of LED Indicators 15 Table 3 1 Description of LEDs 15 Figure 3 5 Cleaning the Ink Cartridge 16 Figure 3 6 O...

Page 8: ...Figure 1 1 Excella STX viii...

Page 9: ...The current configuration is as follows Part Number Description 223500001 MICR EXCELLA STX USB ETH COLR MSR FPRT BPRT 223500002 MICR EXCELLA STX USB ETH COLR MSR FPRT BPRT W DEV KIT 223500003 MICR EXC...

Page 10: ...Reader with MagnePrintTM ACCESSORIES Accessories available for the Excella Reader include the following STX accessories P N listing Description 22350300 COM USB 2 0 A B BLK 6 22350301 COM USB 2 0 A B...

Page 11: ...s are offered as an option CCITT G4 or JPEG Check Feed Manual feed of a single check MICR fonts supported E13 B CMC 7 Interface Options RS 232 USB 2 0 USB 1 1 compatible Ethernet 100 Base T Magnetic S...

Page 12: ...Excella STX Installation and Operation 4...

Page 13: ...d uninstalled 3 Install Excella STX API Demo software CD provided by MagTek 4 Connect interface cable USB or Ethernet and power cable to Excella STX 5 Connect power cord to AC wall outlet 6 Connect in...

Page 14: ...bs on the inner race of the Outer Cover as shown in Figure 2 1 The left Release Button is shown the Right Release Button is directly opposite 2 As indicated in the illustration press the two Release B...

Page 15: ...ger on the front Release Buttons as indicated in Figure 2 2 2 Place the index finger on the rear Release Button not shown as indicated in the illustration The location of the rear Release Button is sh...

Page 16: ...et 2 Slide the guide pegs into the guide holes as indicted in Figure 2 4 3 Raise the latch so that it touches the Printer Cartridge 4 Press the latch into the lock position and move the Cartridge slig...

Page 17: ...ower the front of the Cover so the pins slide into the holes in the Cover and the front of the Cover latches Outer Cover Replacement 1 Place two index fingers on the Release Buttons and two thumbs on...

Page 18: ...ration 10 CABLE CONNECTIONS The cable connections are shown in Figure 2 5 Figure 2 5 Cable Connections CABLING Cabling for Power Supply and Cords is as shown in Figure 2 6 Figure 2 6 Power Supply and...

Page 19: ...lation 11 The Cabling for the USB cable 22350300 is as shown in Figure 2 7 Figure 2 7 Cabling USB 4 pin P N 22350300 Cabling for the Ethernet P N22350302 is shown in Figure 2 8 Figure 2 8 Cabling Ethe...

Page 20: ...Excella STX Installation and Operation 12...

Page 21: ...cribed in Section 2 POWER UP Plug the power supply P N 64300098P N and cord 71100001 into wall power and press the start button The green LED in the middle of the unit should light OPERATION Check Ins...

Page 22: ...ng with the front of the card facing the scan bar as shown in Figure 3 2 The right exit port will flash when the ID card is requested Figure 3 2 Position for Holding and Entering ID Card Magnetic Swip...

Page 23: ...of LEDs Middle LED Unit Status Description Steady Green Power on everything is OK Slow Blink Amber Cover open Fast Blink Red Doc jammed Path not clear Middle LED MSR Status Slow Blink Green Swipe car...

Page 24: ...nozzles on the Printer Cartridges dry wiping and damp wiping Use the dry wiping method first and if more cleaning is required use the damp wiping method Figure 3 5 shows the Ink Cartridge Figure 3 5...

Page 25: ...th a clean dry cloth Scan Bar Cleaning With the Outer and Center Covers removed locate the Hinged Roller Tower and the Scanning Tower Open the Towers as indicted in Figure 3 6 and Figure 3 7 and perfo...

Page 26: ...Excella STX Installation and Operation 18 2 On the Exit side pull the Tab up and the Scan Bar Tower down to the right Figure 3 7 Opening Right Scan Bar...

Page 27: ...de and Center Covers and open the Scan Bars as previously described Remove larger debris such as jammed checks or cards from the check and card paths For finer particles use compressed air in a can th...

Page 28: ...Excella STX Installation and Operation 20...

Page 29: ...example if Excella STX s active device IP address is 192 168 160 2 type the http 192 168 160 2 in your web browser to access Excella STX s web page This appendix provides a general description of the...

Page 30: ...for Excella STX Also the device s clock can be set on this page Figure A 2 Maintenance Page CALIBRATE Scanner calibration is performed at the factory and subsequent calibrations are NOT required unde...

Page 31: ...provided in a file with the mef extension Figure A 3 Update Firmware Page Using the Update Firmware page Figure A 3 follow these instructions to download new firmware 1 Click on the Browse button to l...

Page 32: ...irmware Update message will appear with information as follows Filename ms117x mef Size 413816 bytes Upgrade completed 5 At this time cycle the power of Excella Off On CONFIGURATION The Configuration...

Page 33: ...be setup appropriately to use this option This name must be unique for each Excella STX device on the network The default factory value is EX followed by the unit s S N e g EX A03LEY9 HTTP Port The de...

Page 34: ...ve the current settings to the Excella STX device Ethernet Configuration Tab Figure A 5 Ethernet Configuration Tab MAC Address The MAC Media Access Control address uniquely identifies each Excella STX...

Page 35: ...e the Gateway value The default factory value is 0 0 0 0 IP Source Select the Fixed option if the values will be set manually using this page Select the DHCP option if the Network server will dynamica...

Page 36: ...Excella STX s device IP address Use this option to change the IP address value The default factory value is 192 168 160 2 Subnet Mask Use this option to change the Subnet Mask value The default facto...

Page 37: ...Config utility See Appendix B on the PC to set these values when the RNDIS option is selected Select the Fixed option if the values will be set manually using this page Cancel Changes Button Click on...

Page 38: ...current configuration options to a Config file on the PC The default filename is excella_config ecg Reset Config to Factory Defaults Click on the Reset to Default button to restore ALL default factor...

Page 39: ...lity will automatically select and configure IP address for the PC and Excella STX Note ExcellaUSBConfig must be run to establish a connection between the PC and Excella STX After Excella STX s API De...

Page 40: ...er C Program Files Magtek Excella STX Demo Run the ExcellaUSBConfig exe program For Subnet Mask Network Device ID and Excella Device accept the defaults shown Click once on the Search button this will...

Page 41: ...s used in the US Canada Australia United Kingdom Japan India Mexico Venezuela Colombia and the Far East The CMC 7 set is used in France Spain other Mediterranean countries and most South American coun...

Page 42: ...C 1 CMC 7 Nonnumeric Characters CMC 7 Character MICRImage Reader Output SI A SII B SIII C SIV D SV E CHECK LAYOUTS Personal checks with MICR fields are shown in Figure C 1 Business checks are shown i...

Page 43: ...the numbers below the checks on the illustration and represent the 4 MICR fields 1 Transit Field The Transit field is a 9 digit field bracketed by two Transit symbols The field is subdivided as follow...

Page 44: ...ber Check number and or a transaction code Note that an On Us symbol must always appear to the right of the account number 3 Amount Field The Amount field is a 10 digit field bracketed by Amount symbo...

Page 45: ...f the Program s source code as you receive it in any medium provided that you conspicuously and appropriately publish on each copy an appropriate copyright notice and disclaimer of warranty keep intac...

Page 46: ...NSED FREE OF CHARGE THERE IS NO WARRANTY FOR THE PROGRAM TO THE EXTENT PERMITTED BY APPLICABLE LAW EXCEPT WHEN OTHERWISE STATED IN WRITING THE COPYRIGHT HOLDERS AND OR OTHER PARTIES PROVIDE THE PROGRA...

Page 47: ...39...