Push this button over 2 seconds to turn 

on or turn off the product. 

The  product  automatically  powers  off 

after  15  minutes  of  inactivity  and  the 

built-in  beeper  beeps  5  times  1  minute 

before auto power off. 

To  cancel  auto  power  off,  push  NCV 

before  turning  on  the  product,  after  5 

beeps  to  cancel  the  auto  power  off 

successfully.

Push once to hold the current reading 

on the display;  

Push for more than 2 seconds to turn on 

the flashlight backlight. And long-push 

again to turn off. 

Keep pushing this button to enter the 

NCV testing mode. In this mode, you 

have to continually push the NVC 

button. The NCV function cannot be 

used when test leads are in the current 

terminal. 

INSTRUCTION MANUAL

- 3 - 

- 4 - 

All rights reserved.  

Specifications are subject to change without notice.

Introduction

 

This  product  is  a  battery-powered,  auto-ranging, 

true  RMS  digital  multimeter  with  a  4000  counts 

LCD display.  

Safety Information 

To  avoid  possible  electrical  shock,  fire,  or 

personal injury, please read all safety information 

before  you  use  the  product.  Please  use  the 

product  only  as  specified,  or  the  protection 

supplied by the product can be compromised. 

• Examine the condition of the test leads and the

casing before you use the product. Look  for

cracks  or  missing  plastic.  Carefully look at

the insulation around the terminals & test leads.

• The  measurement  must  be  made 

within  the

allowable measuring range

.

• Do  not  use  the  product  around  explosive  gas,

vapor, or in damp or wet environments.

• When the voltage to be measured exceeds 36V

DC  or  25V  AC,  the  operator  must  be  careful

to avoid electric shock.

• Misuse of mode or range can lead to hazards,

be cautious. “OL” will be shown on the display

when the input is out of range.

• Low  level  of  a  battery  will  result  in  incorrect

readings.  Change  the  batteries  when  battery

level is low. Do not make measurements when

the battery door is not properly closed.

-

 2 - 

Instruction

 

Buttons 

Measurements 

Measure DC/AC Voltage (

>0

.8mV) 

1. Only  when  the  voltage  is  higher  than  0.8mV,

this product will show the display.

2. Put the red lead into the              terminal, put

the black lead to the COM terminal

.

3. The DC or AC voltage will be auto matched.
4. Touch  the  probes  to  the  correct  test  points  of

the circuit to measure the voltage.

5. Read the measured voltage on the display.
Measure Resistance
1. Put the red lead into the

 terminal, put 

the black lead to the COM terminal

.

2. The resistance measure will be auto matched.
3. Touch  the  probes  to  the  desired  test  points  of

the circuit to measure the resistance.

4. Read the measured resistance on the display.
Test for Continuity

1. Put the red lead into the

 terminal, put 

the black lead to the COM terminal

2. The continuity measure will be auto matched.
3. Touch  the  probes  to  the  desired  test  points  of

the circuit.

4. The  built-in  beeper  will  beep  when  the

resistance is lower than 50Ω, which indicates a

short circuit while the central LED light will light .