mt
MT 150 SET USERS MANUAL
GENERAL SPECIFICATIONS
MT 150 SET is a wireless room control.The user adjusts the working temprature of the boiler at the
desired level in order to provide more comfort.
•
Wireless
•
Sensitive temprature measuring
•
Heat calibration
•
ON/OFF control
TECHNICAL DATA
2.1 Voltage
: 3V ± 0.2V (DC)
2.2 Currency Load
: 10 A
2.3 Sensitivity
: ± 0.5
o
C
2.4 Operation Temprature Range
: 5.0
o
C - 30
o
C
2.5 Timing Error
: < % 1
2.6 Battery Life
: 1 year (2×AAA)
INSTALLATION OF MT 150 SET
In order to demount wall hook of MT 150, please drag the room control to yourself from the left or
right direction. Fix the wall hook at a central location of the house at a height about 150 cm from the
floor. Avoid installing the device at door entrance or near a window where air circulation is intense.
Summary of Contents for MT 150 SET