background image

03POH1010-V2

Overall Dimensions:

 

Length = 308cm 

Width = 314cm 

Height = 211cm 

Base Dimensions: 

Length = 306cm 

Width = 306cm 

For Assistance Please 

Contact Customer Care on 

01636 880514

2mm Drill bit

x2

Winter = High Moisture = Expansion

Summer = Low Moisture = Contraction

This building should be erected by 

two people.

For ease of assembly, you must pilot 

drill all screw holes and ensure all 

screw heads are countersunk.

BEFORE YOU START PLEASE READ INSTRUCTIONS CAREFULLY 

- Check the pack and make sure you have all the parts listed. 

- When you are ready to start, make sure you have the right tools at hand 

(not supplied) including  a Phillips screwdriver, Stanley knife, wood saw, 

step ladder and drill with 2mm bit.

- Ensure there is plenty of space and a clean dry area for assembly. 

TIMBER

As with all natural materials, timber can be affected during various weather 

conditions. For the duration of heavy or extended periods of rain, swelling of the 

wood panels may occur. Warping of the wood may also occur during excessive 

dry spells due to an interior moisture loss. Unfortunately, these processes cannot 

be avoided but can be helped. It is suggested that the outdoor building is 

sprayed with water during extended periods of warm sunshine and sheltered as 

much as possible during rain or snow. 

Our buildings are delivered pre-treated with a water based timber treatment 

however this only helps to protect during transit of your garden item. To 

validate your guarantee and for better protection against weathering it is 

ESSENTIAL that you treat the garden building with a wood preserver within 3 

months of assembly. This will need to be re-applied annually to ensure longevity 

of your building. Care must be taken when constructing the garden building 

that it is not touching the ground and is on a suitable base.

BUILDING A BASE

When thinking about where the building and base is going to be constructed: Ensure that there will be access to all sides for maintenance 

work and annual treatment.

TYPES OF BASE

- Concrete 75mm laid on top of 75mm hard-core.

- Slabs laid on 50mm of sharp sand.

Ensure the base is level and is built on firm ground, to prevent distortion.  Refer to diagrams for the base dimensions,  The base should be 

slightly smaller than the external measurement of the building, i.e. The cladding should overlap the base, creating a run off for water. It is also 

recommended that the floor be at least 25mm above the surrounding ground level to avoid flooding.

Whilst all products manufactured  are made to the highest standards of Safety and in the case of childrens products independently tested to EN71 
level, we cannot accept responsibility for your safety whilst erecting or using this product.

Please retain product label and instructions for future reference

             

Before assembly  

please make sure you have a 

suitable base ready to erect your 

building 

 

MADE IN GREAT BRITAIN

Window Panel 1

Window Panel 2

Door Panel 1

Door Panel 2

Back Panel 1

Plain Door x3

Master Door

Back Panel 2

Roof x2

Floor x2

2

1

3

4

5

6

7

8

50mm Screw x80 

40mm Screw x35

Felt Tacks x130

30mm Screw x117 

50mm Bolt x2 

70mm Screw x2

10mm Screw x40

100mm Screw x8

35

36

Summary of Contents for 03POH1010-V2

Page 1: ...otection against weathering it is ESSENTIAL that you treat the garden building with a wood preserver within 3 months of assembly This will need to be re applied annually to ensure longevity of your building Care must be taken when constructing the garden building that it is not touching the ground and is on a suitable base BUILDING A BASE When thinking about where the building and base is going to...

Page 2: ...of door handles Chrome handle Barrel bolt Felt 58x44x1943mm Panel Frame x1 20 21 22 23 24 25 26 27 28 29 9 10 11 12 13 14 15 16 17 18 19 27x45x1558mm Roof Eave x2 16x60x1720mm Door Strip x2 30 31 32 33 Mortice Lock Key Plate 37 Butt Hinge x12 a a a a a a a a a a a a 4 3 a 35 35 36 35 37 30mm screw Pre Assembly Fix the butt hinges to the doors and both door gables using 30mm screws ensuring that th...

Page 3: ...x30mm screws Then fit barrel bolts to top and bottom of the doors as shown in diagram Use 4x10mm screws per barrel bolt Ensure doors open and close freely Step 2 30mm screw 10mm screw 10mm screw 31 31 28 3 4 32 33 The Mortice Lock is Reversible Step 4 Place Back Panel 2 on top of floor as shown Pre drill 3 holes from Back Panel 2 and into Rear Panel Framing and attach together using 3 x 50mm screw...

Page 4: ...ther panels using 50mm screws as shown in fixing method b pre drill holes first Slot the remaining panel frame against both panels on the corner and fix using fixing method a Pre drill holes first a a a a a a b b b b b b b 50mm screw 12 x 50mm screws 3 9 4 Step 8 We strongly recommend pre drilling holes before fixing screws 100mm screw 100mm screw 40mm screw Layout all the labelled parts used here...

Page 5: ...block to corner of one the roof panels as show below pre drill holes from the outside and fix using 2 x 50mm screws Place roof panels on top making sure the roof block fits over the corner of the building as shown below Fix the roof block to the corner using 1 x70mm screw ensure to pre drill hole first Fix roof panels to building using 50mm screws 1 x 70mm screws 20 x 50mm screws We strongly recom...

Page 6: ... to floor using 50mm screws in the position shown again we recom mend pre drilling holes before hand to reduce the risk of splitting the wood Make sure to align the screws with the floor joists 50mm screw 50mm screw 17 x 50mm screws Step 13 40mm screw Step 11 Fix Roof Eaves to the back of the roof panels as shown Using 3 x 40mm screws per piece Ensure to pre drill holes first to avoid splitting wo...

Page 7: ...14 Fix rear cover trim to back corner using 3 x 30mm screws Pre drill holes first 30mm screw 3 x 30mm screws 20 Step 15 Fit the fascias to the building over the felt and secure in place with 40mm screws as shown Pre drill to avoid splitting 18 x 40mm screws 40mm screw 21 21 22 22 21 21 Step 16 Pre drill holes then fix Chrome Handle using 45mm bolt as shown in diagram We strongly recommend pre dril...

Page 8: ...nd protective cover on glazing and carefully peel covering back Attach to this door Attach to this door 30mm screw 30mm screw Fix Door strips to outside make sure to fit them to the door without a handle on either side Ensure there is enough cover over the other door Fix using 4x30mm screws per strip making sure to pre drill Step 18 27 27 ...