background image

 

 

 

 

 

PROGRAMMING GUIDE

®

 

 

 

 
 
 
 
 
 
 
 
 

 

  

  

  

  

  

  

  

  

 

 

MARKS USA 

365 Bayview Ave., Amityville, NY 11701 

631-225-5400 

•  1-800-526-0233  •  Fax 631-225-6136 

Summary of Contents for i-Qwik LITE Series

Page 1: ...PROGRAMMING GUIDE MARKS USA 365Bayview Ave Amityville NY 11701 631 225 5400 1 800 526 0233 Fax 631 225 6136 ...

Page 2: ... Groups Page 1 To Add Users Page 1 To Delete Users Page 1 Pin Only Entry Page 2 Change User Pin Page 2 Define Open Time Page 2 Lock Audio Page 2 Terminator On Off Page 2 Manual Passage Mode Page 3 Temporary User Schedule Page 3 Set Time Page 3 Set Date Page 3 Double Code Entry Page 3 Privacy Mode Secretary Mode Page 4 Disable Enable Three Strike Lockout Page 4 Clear Memory Page 4 Battery Check Sta...

Page 3: ...ithin 5 seconds CREATE MASTER CODE This code is required to perform all programming functions The number of digits used for the User ID and PIN of each additional usermustbethesameastheMasterCode Enter 9991234 UserID PIN UserIDandPINfollowedby willopenthelock GROUPS ALL USERS MUSTBE ASSIGNED TO A GROUP Users in the same group will have the same access rights Eachgroupisassigneda2digitgroupnumberfr...

Page 4: ...illstayunlockedafteravalidUsercodehasbeenentered Theopentimecanbesetfrom1to9seconds Defaultsettingis3seconds Enter MASTER CODE 18 SingleDigit1 9Seconds LOCK AUDIO Whentheaudioissetto ON thelockwillbeepwitheachkeypressed Onbydefault AUDIO OFF Enter MASTER CODE 34 0 AUDIO ON Enter MASTER CODE 34 1 TERMINATOR ON OFF This function will switch the Terminator On or Off Selecting off automatically sets l...

Page 5: ...ned or access repeats annually This function requires setting the date in the lockset see Set Date below Enter MASTER CODE 06 UserID MMDD Start Date MMDD EndDate SETTIME Thisfunctionwillsetthetime HHMM Timeissetin24hourformat Example 3 30pm 1530 Enter MASTER CODE 12 HHMM Daylightsavingstimeisenabledbydefault Todisabledaylightsavingsadda 0 zero attheendofthetimeentry Example 3 30pm 15300 SET DATE T...

Page 6: ...e to 40 seconds maximum Disabling this feature allows an unlimited number of incorrect codes to be entered without a lockout DISABLE Enter MASTER CODE 40 0 ENABLE Enter MASTER CODE 40 1 CLEAR MEMORY If it becomes necessary to reset the memory of the i Qwik LITE there are two options other than the Full Reset option DELETEALLUSERS SCHEDULES Enter MASTER CODE 16 16 0 DELETE ONLY SCHEDULES Enter MAST...

Page 7: ...rve determines the power settings for thetwostagesofbatterywarningsandtheFailSecuresettings Alithiumbatterydiffersfromanalkalinebatteryinthelifecycleofthebatterycell Alithiumbatteryhasavery sharp drop off voltage going from fully charged to a dead cell quickly This makes monitoring the voltage settings impossible TWO STAGE LOW BATTERY WARNING The i Qwik LITE has a two stage low battery warning The...

Page 8: ... product line templatesandmanuals visitourwebsite www marksusa com For i Qwik i Que Tech Support Call Toll Free 800 526 0233 In N Y 631 225 5400 Fax 631 225 6136 LIVE TECH SUPPORT 8am to 8pm EST Mon Fri Email techsupport marksusa com IP101 IQWIKLITE 03 09 2009 MARKSUSA Distributed by ...

Reviews: