background image

user manual

Exterior 1200

Image Projector

Summary of Contents for Exterior 1200

Page 1: ...user manual Exterior 1200 Image Projector ...

Page 2: ...ct to change without notice Martin Professional A S and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual Please check with your Martin Architectural supplier that you have the latest product information before in...

Page 3: ...3 Section 1 Safety ...

Page 4: ...omponent or cover is damaged cracked or deformed Switch the lamp off allow the luminaire to cool with fans running for 20 minutes then isolate it from AC power and lock out power before removing or installing the lamp fuses or any part Ensure that the luminaire is correctly configured for the local AC power voltage as described in this manual before applying power for the first time Always ground ...

Page 5: ... explodes in a confined area evacuate the area and ventilate it thoroughly Wear non porous safety gloves when handling a broken discharge lamp Treat broken or used discharge lamps and used safety gloves as hazardous waste and send to a specialist for disposal Replace the lamp if it becomes visually deformed damaged or in any way defective Replace the lamp at the latest when it reaches the limit of...

Page 6: ... from a stable platform whenever installing servicing or moving the luminaire Ensure that all supporting structures surfaces fasteners and lifting equipment can bear the weight of all the devices they are intended to support plus an adequate safety margin and that they conform to local building and safety regulations Use a sufficient number of fasteners with sufficient corrosion resistance dimensi...

Page 7: ...am at lamp off 29 4 1 6 Onboard control panel 30 4 1 7 Cooling fans 31 4 1 8 LEDs and operating status 31 Section 5 Settings and configuration 33 5 1 Luminaire settings 34 5 1 1 Setting up a luminaire with a PC and MUM 35 5 1 2 Setting up a luminaire with the onboard control panel 37 Section 6 Stand alone operation 39 6 1 Stand alone programming general 40 6 1 1 Introduction 40 6 1 2 Synchronized ...

Page 8: ...Seals 61 8 4 2 Cable glands 61 8 4 3 Torque settings 62 8 5 Lamp maintenance 63 8 5 1 Approved lamp 63 8 5 2 Lamp life and monitoring lamp hours 63 8 5 3 Installing the lamp 64 8 6 Removing the effects lamp module 67 8 7 Installing a filter in the color wheel 68 8 8 Installing a rotating gobo 69 8 9 Installing a permanent filter kit 71 8 10 Installing a gobo animation wheel 72 8 11 Alternative len...

Page 9: ...Section 2 Introduction ...

Page 10: ...n electrician data DMX system installer Section 4 General page 27 Main features and functions as well as programming and operating principles All involved in programming and operating Section 5 Settings and configuration page 33 Instructions for carrying out basic configuration All involved in programming and operating Section 6 Stand alone operation page 39 Instructions for setting up and running...

Page 11: ...arp image projections or soft focus animation effects for example The Exterior 1200 Image Projector is available in the following optical configurations ranges indicate minimum and maximum zoom limits All dynamic effects can be controlled using industry standard DMX intelligent lighting control technology or run independent or synchronized stand alone light shows that do not require external contr...

Page 12: ...12 Exterior 1200 Image Projector user manual ...

Page 13: ...Introduction to the Exterior 1200 Image Projector 13 Section 3 Installation ...

Page 14: ...nsert must be removed from the CMY module as described in the next section 3 1 1 Unpacking and preparing for use The Exterior 1200 Image Projector is supplied with the following items A foam block wedged around the CMY flags and a metal bracket on the lens cars see Figure 2 on page 15 to protect components during transport The block and bracket must be removed before use Philips MSD 1200 metal hal...

Page 15: ...d then install the lamp supplied with the product It will almost certainly be easiest if you do this now before the luminaire is installed in its final location Important Keep the shipping bracket and foam insert for future use and install them if you ever need to transport the luminaire See 8 5 3 Installing the lamp on page 64 for instructions on opening the luminaire and installing the lamp 3 1 ...

Page 16: ...stallation consider that the main housing has an ingress protection IP rating of 65 but that the heat exchanger unit must be protected from rain or direct water projections that might fill the heat exchanger with water and cause overheating The luminaire may therefore be installed in any orientation but it must be positioned so that the heat exchanger is on the lower side of the luminaire see Figu...

Page 17: ... installed directly under the fasteners heads when anchoring the yoke base to the installation surface The mounting yoke allows the luminaire to be manually panned i e rotated horizontally and tilted for beam aiming adjustment The yoke base must be safely anchored to a horizontal surface The number and type of fasteners used will depend on the installation but use at least four high strength corro...

Page 18: ...able layout diagram OPTO SPLITTER Power 230V AC 50 Hz Power 230V AC 50 Hz 50 Hz Max 32 luminaires or 500m before opto splitter is required OPTO SPLITTER DMX Universe 1 DMX Universe 2 Universe 2 AC power OPTO SPLITTER Power 230V AC 50 Hz 50 Hz Power 230V AC 50 Hz Max 32 luminaires or 500m before opto splitter is required Max 32 luminaires or 500m before opto splitter is required OPTO SPLITTER DMX U...

Page 19: ...to alter any connections shut down AC power by setting the MAINS switch to 0 off Before you touch any connectors use a tester to check that they are not live After access to the connections compartment 1 Check the condition of the rear cover seal Replace with a new item if the seal is torn cracked or brittle 2 Hold the rear cover plate and seal firmly against the luminaire housing Adjust the sides...

Page 20: ... an electrical cable that is adequately dimensioned for the current requirements and suitable for the installation environment particularly with regard to water pollution thermal and UV resistance Use Hypalon or neoprene rubber jacket cable rated to 90 C 194 F minimum The conductor size must be 1 5 mm2 16 AWG minimum Check that all power cables are in perfect condition See Exterior 1200 Image Proj...

Page 21: ...ing to AC power Power cable must enter the luminaire through an M20 x 1 5 cable gland that accepts 8 13 mm 0 32 0 5 in external diameter cables A gland is supplied with the luminaire The cable gland must be replaced if the power cable diameter is not within this range see 8 4 2 Cable glands on page 61 One of two cable entry points can be used either on the cover plate at the rear of the luminaire ...

Page 22: ... Ground Neutral Live 1 and Live 2 Connect the power cable as follows Connect the power cable s ground earth wire to the terminal marked Ground If using a single phase system connect the power cable s neutral wire to the terminal marked Neutral and connect the power cable s live wire to the terminal marked Live 1 Important Do not connect the live wire to the terminal marked Live 2 as there is inter...

Page 23: ...t these now referring to the next section in this manual Otherwise replace the rear cover plate as described in 3 1 4 Connections compartment access on page 19 Wire EU Wire US Pin Marking Screw US brown black live L yellow or brass blue white neutral N silver yellow green green ground green Table 2 Common wire color codes ...

Page 24: ... ft extend the link to include a further maximum 32 luminaires or branch the link into further single chains each containing 32 luminaires The Martin Opto Splitter allows a link to be branched into four new chains Each chain on the link must be terminated by placing a resistance across the hot and cold conductors of the data link in the last device on the chain This is achieved by setting jumpers ...

Page 25: ...link RJ 45 cable connector pins are numbered from the left looking at the face of the connector with the locking clip on top see Figure 11 Connectors must be wired using the standard RJ 45 DMX pin out Pin 1 WHITE orange DMX hot Pin 2 ORANGE white DMX cold Pins 7 WHITE brown and 8 BROWN white Common Pins 3 and 6 are available for Data 2 connections in DMX 512 A or similar systems They must be wired...

Page 26: ...ire using another cable gland as described above Connect to the luminaire s Data 1 DMX OUT terminals E or RJ 45 DMX OUT socket F respecting the same pinouts as for the data input cable 7 If using shielded CAT5 cable connect the cable shield to PCB ground earth by routing the cable under the clamp G folding back the cable shield and tightening the clamp so that it makes good contact with the shield...

Page 27: ...Installing a data link 27 Section 4 General ...

Page 28: ...ds or run a stand alone show 4 1 2 Maintaining power and temperature regulation Except during service maintain power to the luminaire permanently even when the lamp is not lit In hot environments this will allow the cooling system to regulate the luminaire s internal temperature at all times Heat damage resulting from failure to maintain power is not covered by the product warranty In cold environ...

Page 29: ... on lamps one by one at intervals of about half a second To obtain optimum lamp life Always allow the lamp to warm up fully for 5 minutes before turning it off Switch off the lamp whenever illumination is not required for extended periods of an hour or more Note that luminaire power should remain on at all times except during service 4 1 5 Exercise Program at lamp off To ensure free and correct ef...

Page 30: ...eed information in RPM revolutions per minute for each of the cooling fans The Lamp status list displays a list of resettable counters that indicate hours of lamp use number of times the lamp has been struck powered on and number of times the luminaire has been powered on Control panel The display and control buttons are protected by a clear cover that is secured with Allen screws Remove the cover...

Page 31: ...e event of a problem the Exterior 1200 Image Projector will show a message in the display indicating the type of problem that has occurred 4 1 7 Cooling fans When power is applied cooling fans run at full speed for a few seconds to clear any dust that has accumulated in the heat exchanger After this fan speed is regulated thermostatically to maintain an even temperature in the luminaire When the l...

Page 32: ...32 Exterior 1200 Image Projector user manual ...

Page 33: ...General 33 Section 5 Settings and configuration ...

Page 34: ...ocket We recommend MUM because it provides an intuitive easy to use graphical user interface Note that MUM can only be connected to and set up one luminaire at a time Setup using MUM is described in 5 1 1 Setting up a luminaire with a PC and MUM on page 35 MartinMP 2 Uploader The Martin MP 2 Uploader is no longer available from Martin Architectural as its text based interface has been superseded b...

Page 35: ... the USB cable 3 Connect the DABS1 adaptor to the Exterior 1200 Image Projector using either an XLR connector connected to the data link or the RJ 45 service socket in the connections compartment behind the rear cover plate see G in Figure 12 on page 26 If connecting via the data link note that you may only connect to one luminaire at a time 4 Apply power to the Exterior 1200 Image Projector and s...

Page 36: ...erated 24 hour clock that is used to start and stop stand alone operation To set the clock 1 Click on the Fixture Info button in MUM 2 Using the Fixture real time clock spin buttons set the luminaire to the current time expressed in the 24 hour clock in hours and minutes and date The time will be updated in the luminaire in real time ...

Page 37: ... addresses on page 52 It is also a good idea to set the DMX Lamp Off and DMX Reset options These settings are described in 7 1 Preparing for DMX control on page 52 The other default luminaire settings listed below are suitable for most applications and it may not be necessary to change them Automatic lamp on When the Automatic Lamp On personality is On the default setting the luminaire turns on th...

Page 38: ...is used to start and stop stand alone operation To set the clock 1 If the display is showing Fixture status Fan status and Lamp status press Menu to enter the main menu Scroll down to Personality and press Enter 2 In the Personality menu scroll down to Set clock 3 Set the luminaire to the current time expressed in the 24 hour clock in hours and minutes by entering values for Hour and Minute Use th...

Page 39: ...Luminaire settings 39 Section 6 Stand alone operation ...

Page 40: ...ith multiple luminaires on page 40 for details About scenes A stand alone light show consists of scenes Each scene is a particular lighting effect with predetermined color intensity and duration Up to 20 scenes can be programmed into the Exterior 1200 Image Projector s program memory Each scene has a dynamic part the fade during which effects move to the scene s programmed positions and a static p...

Page 41: ...tailed explanation of synchronized operation and how advanced effects can be created by programming luminaires with a different number of scenes see the next section Synchronized stand alone operation detailed description Note This section gives advanced information about stand alone synchronized operation You only need to read it if you require help with problem diagnosis or if you want to progra...

Page 42: ...onger than the corresponding scenes on the master 6 1 3 Stand alone programming methods You can program stand alone shows on the Exterior 1200 Image Projector using the Martin MUM application on a personal computer recommended because it provides an intuitive easy to use graphical user interface or the luminaire s onboard control panel If you are programming a group of luminaires to perform the sa...

Page 43: ... a luminaire is subsequently switched on it can automatically run the scenes in its program in a loop according to the triggering criteria you have specified time of day and or light level If you are not familiar with the use of MUM it is recommend that you familiarize yourself with it by reading the MUM Help files and MUM user manual 6 2 1 Connecting To establish a connection 1 Connect a DABS1 ad...

Page 44: ...vates or deactivates stand alone operation If enabled stand alone operation will start automatically when the luminaire is powered on or the luminaire is being controlled by DMX and the DMX control signal disappears Synchronized Sets the luminaire to one of the following modes Single Fixture operates in stand alone mode independently of other luminaires Master sends trigger signals to other lumina...

Page 45: ...timer s Setting a light level trigger To set a light level trigger 1 Set Light level sensor trigger to On 2 Set the light level that triggers stand alone operation using the Trigger level spin button or press Capture current sensor value to set the current ambient light level to trigger stand alone operation To avoid false triggering by sudden light changes caused by vehicle headlights or clouds f...

Page 46: ...at 90 to the axis of projection Soft focus gives best results with some animation effects Color filter Click on one of the four square buttons colored blue green red or white to select a filter in the color wheel Note that depending on which filters are installed and their positions in the color wheel the color applied may not be the same as the color of the button in the MUM window Gobo Gobo 1 4 ...

Page 47: ... until the master luminaire signals that the program should start from the beginning again More scenes than the master luminaire then the additional scenes will never run because the program will reset to the first scene when the master starts its program from the beginning Store scene Save settings in the current scene Add scene Save settings in a new scene at the end of the current sequence of s...

Page 48: ...nd then upload the stand alone program and luminaire settings to each subsequent luminaire that you connect to This is useful if you have a group of luminaires of the same type that will run the same stand alone show 6 3 Stand alone programming with the control panel The main stand alone programming commands available in the MUM application are also available in the Exterior 1200 Image Projector s...

Page 49: ...g MUM Stand alone operation in the Stand alone settings window Auto LampOn In the Fixture Settings window Using the onboard control panel Standalone Enable Personality Automatic Lamp On 6 4 2 DMX controller override during stand alone show playback If an Exterior 1200 Image Projector is connected to a DMX controller and receives DMX signals during show playback the stand alone show will stop runni...

Page 50: ...50 Exterior 1200 Image Projector user manual ...

Page 51: ...Stand alone playback 51 Section 7 DMX control ...

Page 52: ...t to receive instructions Exterior 1200 Image Projector luminaires use 17 DMX channels i e the start channel plus the next 16 channels If the control address is set to 1 the luminaire uses channels 1 17 Channel 18 is available as the DMX address for the next luminaire If two or more luminaires are set up with the same address they will receive the same instructions and behave identically Setting u...

Page 53: ...MX Reset feature is ON the default setting the luminaire can be reset from the controller by setting channel 1 to a DMX value from 208 to 217 81 85 When DMX Reset is set to OFF the reset command executes only if channels 3 4 and 5 are set to values from 230 to 232 ...

Page 54: ... channels are all set to a DMX value from 230 to 232 see 7 1 3 DMX Reset option on page 53 7 2 2 Lamp Lamp on If Automatic Lamp On is set to ON this is the default setting see 5 1 Luminaire settings on page 34 the lamp strikes automatically when power is applied to the luminaire If set to OFF a lamp on command must be sent from the controller on DMX channel 1 A large peak of electric current is dr...

Page 55: ...ith three rotating gobos plus an open position as standard Gobos can be indexed or rotated continuously If one of the gobos is selected and set to gobo indexing on DMX channel 8 the indexing angle can be adjusted on channel 9 with fine adjustment of the angle available on channel 10 If one of the gobos is selected and set to gobo rotation on channel 8 the direction and speed of rotation can be sel...

Page 56: ...trol and vector control With tracking control fades are programmed using the controller s fade time The controller divides the fade into small elements that the luminaire tracks The Exterior 1200 Image Projector has a digital filter algorithm that averages several updates to ensure smooth movement Vector control provides a way to program fades on controllers without programmable fade times or cros...

Page 57: ...DMX controller operation 57 Section 8 Service and accessories ...

Page 58: ...inaires are subject to wear and tear over the life of the fixture resulting in gradual changes in color rendition of dichroic filters or the specular properties of reflectors for example The extent of wear and tear depends heavily on operating conditions maintenance and environment so it is impossible to specify precise lifetimes for optical components However you will eventually need to replace o...

Page 59: ...switch shuts down power to the lamp and reapplies power when the temperature has fallen to within safe limits If intermittent lamp cutouts occur stop using the luminaire immediately inspect it and clean it if dirt and dust has built up in the heat exchanger If the heat exchanger appears to be clean contact Martin Architectural for assistance 8 3 1 Cleaning the heat exchanger The heat exchanger coo...

Page 60: ...glass using warm water with a little mild detergent and a soft brush or sponge Do not use abrasive cleaners 5 Rinse with clean water and wipe dry 8 4 Seals and cable glands The main housing has an IP rating of 65 it is protected against dust and can withstand low pressure water jets To maintain protection against dust and water Replace any seal that becomes brittle or shows visible signs of wear E...

Page 61: ...overs is the same 1 Ensure that the seal and mating surfaces are clean 2 Place the cover and seal firmly against the housing Adjust the straight sides of the seal so that they stick out a little just enough so that you can feel the edge of the seal when you run a finger across the joint 3 Cross tighten i e tighten diagonally retaining screws gradually and evenly to the torque settings specified in...

Page 62: ...ge from 2 Nm 1 5 ft lbs to 16 Nm 11 8 ft lbs must be used during service and adjustment Component Torque setting Seal P N A Display cover 2 Nm 1 5 ft lbs 20620160 B Rear cover 7 Nm 5 2 ft lbs 20620130 C Connections box 2 Nm 1 5 ft lbs 20620150 D Front cover 7 Nm 5 2 ft lbs 20620130 E Front glass screws inside luminaire 2 Nm 1 5 ft lbs 20620140 F Cooling fan housing 2 Nm 1 5 ft lbs No seal fitted G...

Page 63: ...ssary and reset the luminaire s Resettable Lamp Hours and Resettable Lamp Strikes counters each time you install a new lamp Two methods can be used to check and reset the counters the onboard control panel or MUM A Checking and resetting the lamp life counters using the onboard control panel The onboard control panel displays the lamp hours and lamp strike counters in the Lamp Status display every...

Page 64: ... the lamp Warning Switch off the lamp allow the luminaire to cool with fans running for 20 minutes then isolate it from AC power and lock out power before servicing Wear safety glasses and gloves while installing or inspecting the lamp To replace the lamp 1 Cut lamp power allow the luminaire to cool with fans running for 20 minutes then isolate it from AC power and lock out power 2 See Figure 18 L...

Page 65: ... latch plate to lock the assembly in the out position 5 See Figure 21 The lampholder is at the rear of the effects modules Note the position of wiring to the lamp Loosen but do not remove the three Allen screws arrowed holding the lampholder To release the lampholder push it in slightly and rotate it so that the holes in the lampholder plate clear the Allen screws then gently pull the lampholder c...

Page 66: ... deactivated 12 Before reinstalling the front cover check the condition of the seal Replace with a new item if the seal is torn cracked or brittle 13 Place the front cover and seal firmly against the housing Adjust the straight sides of the seal so that they stick out a little just enough so that you can feel the seal when you run a finger across the joint 14 Cross tighten the cover screws tighten...

Page 67: ...naire to the lamp effects assembly Connector positions are marked and connectors can generally be installed in one position only 3 See Figure 23 Push on the two tabs one must be pushed down the other up in the slider channels to release the slider complete with lamp effects assembly The assembly can now be removed completely from the luminaire To reinstall the lamp effects assembly 1 Engage the sl...

Page 68: ...n 8 5 3 Installing the lamp on page 64 2 See Figure 24 Access the color filters C from underneath the effects module Rotate the color wheel with your fingers until the position where you want to install the filter is pointing downwards in the wheel 3 To remove a filter gently lever the filter retaining spring A away from the color wheel B lift the filter C away from the color wheel so that it clea...

Page 69: ...y from the lamp but consult your gobo supplier before installing See Figure 26 To obtain a true projection gobos must be designed and installed so that the image is true viewed from the lamp and reversed viewed from the front of the luminaire The gobos in the Exterior 1200 Image Projector gobo wheel are mounted in rotating goboholders To remove a goboholder 1 Lock out power open the luminaire and ...

Page 70: ...tly until the spring engages Push down on the retaining plate tab A so that the retaining plate locates in the slot B in the goboholder and the retaining plate is held firmly in the gobo wheel 2 See Figure 29 When the goboholder is correctly installed the outer edge of the retainer plate is perfectly concentric with the outer edge of the gobo wheel so that distances A B and C are exactly the same ...

Page 71: ...led in the Exterior 1200 Image Projector effects module This allows a CTC filter to be installed to match the luminaire s color temperature with other luminaires See Figure 30 The filterholder is inserted from the bottom of the effects module and is held in position by clips A and a retaining bolt B B A Figure 30 Permanent filterholder ...

Page 72: ...most limit of its travel 3 The animation wheel is held in place by a magnetic mount Lever the installed wheel away from its hub to release it 4 See Figure 32 When installing the new animation wheel turn it so that the shiny side faces the lamp and the magnetic ring in the center of the wheel faces the hub in the luminaire Then line up the lug that sticks out of the hub with the cutout in the wheel...

Page 73: ...rear cover plate One fuse protects the connection labelled Live 1 and one protects Live 2 If the luminaire fails to respond when power is applied one of these may have blown To replace a main fuse 1 Switch off the lamp allow the luminaire to cool with fans running for 20 minutes then isolate it from AC power and ensure that power cannot be reconnected accidentally 2 Remove the rear cover plate as ...

Page 74: ...l as hardware monitoring information software and bootloader version details are displayed 8 13 2 Restoring factory defaults The Exterior 1200 Image Projector factory default settings can be restored if required using the Personality Factory default command in the onboard control panel 8 13 3 Updating software The most recent software versions for all Martin Architectural products are available fr...

Page 75: ... that are connected to the link and powered on If you upload via the DMX data link but apply the Force upload command in the Utility menu of one luminaire and carry out a boot mode upload as described in the upload device s documentation software will only be uploaded to the one luminaire you have set to Force upload mode When an upload is completed and when booting up the Exterior 1200 Image Proj...

Page 76: ...ctly refer to Martin Architectural for boot mode upload Luminaire cuts out intermittently especially in hot weather Luminaire temperature too high thermal cutout shutting down power to avoid overheating Stop using luminaire Inspect for dirt buildup and clean if necessary If luminaire is clean or if problem reoccurs stop using luminaire and refer to Martin Architectural No light output Lamp has bee...

Page 77: ... color filter in a metal filterholder that can be permanently installed in the lamp effects module is available from Martin Architectural With the filter fitted color temperatures are reduced giving warmer colors but with slightly reduced light output Snoot barndoors kit Other accessories such as snoot barndoors accessories that can be used to mask the beam and control glare are available from Mar...

Page 78: ...78 Exterior 1200 Image Projector user manual ...

Page 79: ...Accessories 79 Section 9 Reference ...

Page 80: ... Setting Hz Setting Volt Setting Volt Setting Live 2 Live 2 Fuse Live 1 Live 1 Fuse Ground Neutral Live 1 Live 1 Live 2 Live 2 50 60 277 250 240 230 220 208 200 Hz Setting Hz Setting Volt Setting Volt Setting Service RJ45 DMX IN Cable impedance 100 120 B A Service port RJ 45 socket B AC power frequency setting jumper C AC power voltage setting jumper D Main power on off switch E AC power connectio...

Page 81: ...he software version is 1 3 0 LED 1 flashes red once and LED 2 flashes green three times LED 1 LED 2 Status Steady green Effects OK Steady green Data OK Off Waiting for data Steady red Invalid data no data Steady red Steady red Display software being updated Steady yellow Steady yellow Waiting for upload or upload in progress Flashing yellow Flashing yellow Reset in progress Steady green Flashing y...

Page 82: ...pplied to luminaire Fan regulation When enabled cooling fan speed is temperature regulated when disabled fans run at full speed Display Errors When enabled gives priority in the display to error messages Setup C F Set temperature readouts to degrees Centigrade or Fahrenheit Set backlight level Set brightness of display backlighting 0 100 Set clock Set real time clock Reset counters Reset all count...

Page 83: ...ion wheel angle horizontal vertical Adjustment Adjust gobo animation indexing or rotation speed 0 255 Set Gobo Mode Index Rotate Set rotating gobo to indexing or rotation Gobo 1 4 Select rotating gobo 1 4 Adjustment Adjust rotating gobo indexing or rotation speed 0 255 Set Focus Set focus position 0 255 Set Zoom Set zoom position 0 255 Optical Change Pos Move zoom and focus cars to correct positio...

Page 84: ...1 49 50 51 99 100 101 149 150 151 199 200 227 228 255 0 1 19 20 20 39 39 40 58 59 59 78 78 89 89 100 Color wheel scroll and rotation Indexed scrolling Slot 1 Slot 1 Slot 2 Slot 2 Slot 2 Slot 3 Slot 3 Slot 3 Slot 4 Slot 4 Slot 4 Slot 1 Continuous rotation Clockwise fast slow Counter clockwise slow fast 8 0 9 10 19 20 29 30 39 40 99 100 109 110 119 120 129 130 139 140 255 0 3 4 7 8 11 12 15 16 39 39...

Page 85: ...0 19 20 29 30 39 40 49 50 139 140 229 230 255 0 3 4 7 8 11 12 15 16 19 20 54 55 90 90 100 Animation wheel angle position and function set indexing and rotation direction and speed on channel 12 Open Horizontal angle position indexing Vertical angle position indexing Horizontal angle position continuous rotation Vertical angle position continuous rotation Horizontal vertical angle position indexing...

Page 86: ...uired for open gobo indexing continuous gobo rotation Gobo animation wheel Interchangeable indexing rotation with variable angle speed and direction Mechanical dimmer shutter 0 100 variable dimming instant open and blackout Focus Approx 3 m 9 8 ft to infinity Motorized zoom narrow lens 12 18 Motorized zoom medium lens 18 36 Motorized zoom wide lens 31 51 Zoom limits stated as cut off angles C on t...

Page 87: ...to building member 150 mm 6 in Minimum clearance from center of fixture to side building member 400 mm 16 in Minimum center to center distance in side by side installation 800 mm 31 5 in C on n e ct i o n s Power cable entry IP68 cable gland Power connection Quick connectors Data cable entry IP68 cable gland Data connection RJ 45 or screw terminal quick connectors E lec t ri ca l AC power 200 208 ...

Page 88: ...0 blanking plugs installed metal with neoprene seal P N 13103030 Two main fuses 17 5 AT installed P N 05020045 Main PCB fuse 15 AT installed P N 05020039 User manual P N 35000177 A cc e ss o ri es Narrow lens kit P N 91610083 Medium lens kit P N 91610084 Wide lens kit P N 91610085 Color CTC and diffusion filters for color wheel Contact Martin Architectural for details Custom gobos Contact Martin A...

Page 89: ...ent and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of Martin products ...

Page 90: ...Notes ...

Page 91: ......

Page 92: ...www martin architectural com Olof Palmes Allé 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010 ...