background image

 

 

 

MasterBus Tanklevel Interface 

 

Interface between tank level sensor and MasterBus 

 

 

 

USER AND INSTALLATION MANUAL 

10000016386/01 

 

 

Summary of Contents for MasterBus Tanklevel Interface

Page 1: ...MasterBus Tanklevel Interface Interface between tank level sensor and MasterBus USER AND INSTALLATION MANUAL 10000016386 01 ...

Page 2: ... Liability Mastervolt can accept no liability for consequential damage due to use of the Tanklevel Interface possible errors in the manuals and the results thereof use that is inconsistent with the purpose of the product Disclaimer Our products are subject to continual development and improvement Therefore additions or modifications to the products may cause changes to the technical data and funct...

Page 3: ...perly terminated at the two ends with a terminator Step 3 Connect the sensor wires 3 in case of a switchable sensor 4 5 to the screw terminal 1 Battery positive 2 Battery negative 3 Switched power positive 4 Sensor signal 5 Sensor negative 6 Communication led MasterBus connector Step 4 Connect the battery cables 1 2 in case of a powered sensor Step 5 A flashing LED 6 indicates that the MasterBus c...

Page 4: ... content Example situation resistive type sensor 6 Ohm when empty 186 Ohm when full tank volume 1000 liter When the tank is empty and the sensor is on add 50 liter Check the sensor value on the Monitoring tab and enter this value in the Value 5 field Add another 50 liter check the sensor value and enter this value in the Value 10 field And so on The following table shows the Tanklevel Interface co...

Page 5: ...tton Used during the min max calibration process Value 0 During the calibration process enter the required value according to sensor type 0 0 400 Ohm mA or V Value 100 During the calibration process enter the required value according to sensor type 0 0 400 Ohm mA or V Calibr Values Used during the manual calibration process Lock setup button Press to lock the tank setup configuration Events Event ...

Page 6: ... table shows the Tanklevel Interface monitoring and alarms items as displayed in MasterAdjust Description Default Range Monitoring Level Tank level expressed in 0 100 Volume Tank level expressed in liters or gallons Allow high alarm Option to allow an alarm for an almost full tank Not checked Not checked checked Allow low alarm Option to allow an alarm for an almost empty tank Not checked Not chec...

Page 7: ...quals to the sensor supply voltage Sensor voltage 0 70 V Sensor resistance 0 300 Ohms Sensor current 0 4 20 mA Power consumption 280 mW Languages available English Nederlands Deutsch Français Castellano Italiano Norsk Svenska Suomi Dansk Din rail mounting Yes Din rail 30 mm 1 2 inch Protection degree IP 21 Dimensions 66 x 78 x 32 mm 2 6 x 3 1 x 1 3 inch see drawing below Weight Approx 90 gr 0 20 l...

Page 8: ...ervolt com Location Shipping Power Products LLC N85 W12545 Westbrook Crossing Menomonee Falls Wisconsin 53051 United States Asia Pacific Customer Service T 64 9 415 7261 Option 1 E enquiries bepmarine com Technical Support T 64 9 415 7261 Option 3 E technical bepmarine com Location Shipping BEP Marine 42 Apollo Drive Rosedale Auckland 0632 New Zealand Copyright 2019 Mastervolt All rights reserved ...