background image

Matrix Switch Corporation

MSC-XDM1000S

Product Manual

1RU 16 input 16 output 3G-SDI Modular Video Router with Status Panel

Revision 1.8

Page 1 of 64

© 2013-2018 Matrix Switch Corporation

www.matrixswitchcorp.com

Summary of Contents for MSC-XDM1000S

Page 1: ...ix Switch Corporation MSC XDM1000S Product Manual 1RU 16 input 16 output 3G SDI Modular Video Router with Status Panel Revision 1 8 Page 1 of 64 2013 2018 Matrix Switch Corporation www matrixswitchcorp com ...

Page 2: ...UALITY PERFORMANCE MERCHANTABILITY OR FITNESS FOR PURPOSE Matrix Switch Corporation disclaims all liability arising from this information and its use Use of Matrix Switch Corporation devices in life support and or safety applications is entirely at the buyer s risk and the buyer agrees to defend indemnify and hold harmless Matrix Switch Corporation from any and all damages claims suits or expenses...

Page 3: ...g commands and Panel GPIO commands Improved Software Update documentation Added pinouts for RS 232 and RS 485 serial port and GPIO Auxiliary interface Added XD series systems Revision 1 3 2016 05 17 Added MSC CP59X59E panel Revision 1 2 2015 08 20 Added protocol commands MtxGroup PanelDis and PanelExtEn Updated Mascot protocol information to version 2 4 New manuals for MSC V1616 LS DC MSC 1HD1616 ...

Page 4: ...onnection 17 2 2 2 Loading a preset 17 2 3 Presets Tab 17 2 3 1 Loading Work Matrix from a source target 18 2 3 2 Saving Work Matrix to a target 18 2 3 3 Usage scenarios 18 2 4 Labels Tab 18 2 5 Config Tab 19 2 5 1 System Settings 20 2 5 2 Network Settings 20 2 5 3 Button Panel Settings 21 2 6 Command Tab 22 3 Mascot Control Protocol 23 3 1 Protocol Changes 23 3 2 Telnet Access 24 3 3 Serial Acces...

Page 5: ...mmand 41 3 11 21 PAdd Command 41 3 11 22 PairIO Command 41 3 11 23 PanelCmd Command 42 3 11 24 PanelCmdEn Command 43 3 11 25 PanelCond Command 43 3 11 26 PanelDis Command 44 3 11 27 PanelExtEn Command 45 3 11 28 PanelRate Command 45 3 11 29 PClr Command 46 3 11 30 ProtoSer Command 46 3 11 31 PsetNames Command 46 3 11 32 PSub Command 47 3 11 33 PView Command 47 3 11 34 Reboot Command 48 3 11 35 Rec...

Page 6: ...overy procedure 56 4 3 TFTP Software 57 4 3 1 Windows 57 4 3 2 Mac OS X 58 4 3 3 Linux 58 5 Troubleshooting 60 5 1 Unknown IP address 60 5 2 Unexpected reboots 60 6 Reference 61 6 1 Specifications 61 6 2 Serial Interface Pinout 61 6 3 GPIO Auxiliary Interface 62 6 4 Glossary 63 7 Matrix Switch Corporation Warranty 64 Page 6 of 64 2013 2018 Matrix Switch Corporation www matrixswitchcorp com ...

Page 7: ...ected Inputs with supported standard rate 3G HD or SD SDI signals will be auto re clocked for reduced jitter Other non standard rates between 125 Mbit s and 3 0 Gbit s will be passed through without re clocking or jitter reduction Adaptive cable equalization on each input can equalize input signals from Belden type 1694A cables up to lengths of 400m SD 140m HD and 120m 3G SDI BNC Video Outputs Con...

Page 8: ...etails General Purpose I O A D25 connector provides a GPIO auxiliary port with up to 24 input or output 3 3V logic lines for control and status interfacing with external equipment LEDs buttons etc See GPIO Auxiliary Interface for more details 1 2 Video I O Boards The MSC XDM1000S modular router can be configured or expanded in the field for matrix sizes in increments of 8 inputs or outputs Each in...

Page 9: ...or by feel slightly more difficult 3 Ensuring the correct type of board is being used for a slot Input or Output position the board connector first opposite side of the BNC connectors and board main component side towards the top of the router as depicted in Figure 5 Insert the card until it makes contact with the main crosspoint board backplane The card may need to be tilted up or down until it m...

Page 10: ... it is inserted into To remain cost effective it is thus recommended that transmit only or receive only SFP modules are used when planning system I O Model Description MSC SFPTX F1310 10KM 3G SDI SFP Video Transmitter SMF 1310nm 10km LC connector MSC SFPRX F10KM 3G SDI SFP Video Receiver SMF 1310nm 10km LC connector MSC SFPTX HDMI HDMI Transmitter HDMI D Connector MSC SFPRX HDMI HDMI Receiver HDMI...

Page 11: ...n the Software failsafe recovery procedure is entered Routing matrix is initialized to Preset 0 state defaults to source 1 connected to all destinations 1 4 Front Status Panel The MSC XDM1000S has a status front panel with 3 LED indicators described in the following table Page 11 of 64 2013 2018 Matrix Switch Corporation www matrixswitchcorp com Figure 6 MSC SFPTX F1310 10KM SFP Fiber Optic Transm...

Page 12: ...Audio Routers 192 168 2 60 Remote Button Panels 192 168 2 64 Remote LCD Screen Panels 192 168 2 80 Table 4 Default System IP Addresses To access the web page interface of the device 1 Connect the Ethernet port of a computer either directly to the device using a straight through or crossover cable to the same Ethernet network through a network switch or other LAN infrastructure 2 Manually configure...

Page 13: ... Web Page Interface can be used for modifying labels Click the Save button to store any changes that are made Refer the Labels Tab section for more details 1 5 5 Presets There are 10 stored matrix routing presets Preset 0 is recalled on power up and by default routes source 1 to all destinations All other presets default to No Change for all destinations which when recalled will have no effect Pre...

Page 14: ...network unique IP addresses should be assigned from the applicable network and the Netmask setting of the devices should be set to reflect the class size of the IP network the default of 255 255 255 0 is for class C which accommodates up to 254 addresses The Gateway setting is required to be set to the IP address of the network gateway on remote panels which will be accessing routers across networ...

Page 15: ...installation example consisting of a 32x32 SDI Video Router with a secondary level 32x32 Analog Audio router connected via the AFV DB 25 interface a 32x32 Remote Button Panel a 2RU LCD Remote Panel and a Computer system Page 15 of 64 2013 2018 Matrix Switch Corporation www matrixswitchcorp com ...

Page 16: ...utlines to aid in further description below The web page interface for other router systems is sized appropriately Remote Panels show only the Config and Command tabs Numbered sections in Figure 10 1 System name can be assigned on the Config tab 2 System firmware series and version 3 Tab navigation 4 Preset load drop down selection 5 Source connect buttons 6 Mute button may not be available on all...

Page 17: ...he Destination or a single level is selected 2 2 2 Loading a preset Presets store connection states for one or more Destinations Loading a Preset on the Routing tab consists of simply clicking on the Load preset drop down selector 4 in Figure 10 and selecting the desired preset which is then loaded and applied to the current routing matrix More information on Presets is contained in the following ...

Page 18: ...to a Preset will store the Work Matrix state to non volatile memory which persists through device power cycles and can be recalled at a later time 2 3 3 Usage scenarios The flexibility of the Presets Tab interface allows for several useful scenarios some of which are described below Batch connection operations To perform several connection operations all at the same time make the desired connectio...

Page 19: ...olumns for Video and Audio Sources and Destinations Single level routers will have a column for Source labels and one for Destination labels On multi level routers secondary levels can be left blank to use the same label as the first level Presets can also be assigned label names Click the Save button to save changes that have been made 2 5 Config Tab Page 19 of 64 2013 2018 Matrix Switch Corporat...

Page 20: ...5 characters displayed at the top of the Web Page interface which is helpful when managing multiple systems Disable Reclockers Disable SDI reclockers not supported by all Routers 3D I O Pairing Enable pairing of destinations sources for two channel 3D support only supported by Routers with 2 or more destinations 2 5 2 Network Settings WARNING DHCP should only be enabled or the IPAddress or Netmask...

Page 21: ...te panels control different levels of a Video Audio Router Control Mode Set the matrix control mode only present on Routers Available options include Local Button panel controls the router itself Remote Button panel controls a remote router at the IP address set by the Remote Router IP field Remote Sync Synchronize matrix crosspoint changes to another router at the IP address specified by the Remo...

Page 22: ...the Command text entry line followed by pressing the Enter key to execute them The results will be displayed in the text area below the command line Clicking the Clear Output button will clear all command output in the lower area See the section Mascot Control Protocol for more information Page 22 of 64 2013 2018 Matrix Switch Corporation www matrixswitchcorp com ...

Page 23: ...k without modification using this protocol For information about other third party control system manufacturers who support MASCOT contact Matrix Switch Corporation 3 1 Protocol Changes As new commands are added or other changes occur the MASCOT protocol version is incremented The protocol revision can be obtained using the MascotVer command Protocol revision history Mascot version 3 0 Added Syste...

Page 24: ...and prompt character 3 3 Serial Access Matrix Switch router systems come equipped with a serial port which can be used as another means of sending Mascot commands Connect a Computer system to the device using a 9 pin RS 232 serial cable Using this interface requires a serial terminal program such as HyperTerminal on Windows Configure the terminal software for 115200 bps 8N1 In addition Local Echo ...

Page 25: ...ASCII 10 The Prompt A prompt character is displayed each time a command or chain of commands is entered to indicate readiness to receive additional commands If an error occurs in response to a command an error will be displayed prior to the prompt with the following format E00 Error message 00 will contain a 2 digit decimal error code Table 6 shows possible error codes which may be returned in res...

Page 26: ...omatically interpret argument as string spaces and commas not allowed Hex 0x3D 0xNN where NN are 2 hex digits from 0 9 A F or a f Double quoted One or more characters surrounded by double quotes An Argument Single quoted One or more characters surrounded by single quotes An Argument Table 7 Basic Argument Types Arguments are shown in the Help command output surrounded by square brackets Arg or par...

Page 27: ...ported String String A generic string argument max length depends on the command Value A general value Value type depends on setting See System Parameters Table 8 Command Argument Types 3 7 System Parameters MASCOT protocol version 3 0 adds commands for setting and querying configuration and other system parameters These commands greatly simplify the MASCOT command set and supersede several config...

Page 28: ...serial port baud rate in bits second ctl serial2 log Boolean RW AS RS 485 serial port protocol log enable ctl serial2 proto String RW AS RS 485 serial port protocol selection mascot svs etc mtx serial Number R Current matrix serial number incremented on every routing change mtx sync Boolean RW AS Keep current routing state stored to preset 0 Effectively retains last matrix routing state even after...

Page 29: ... implementation and support variations between different system types Many of these commands have been superseded by System Parameters in Mascot protocol version 3 0 Command Arguments Description DHCP 0 1 DHCP enable FrameIP IP Remote router IP address the panel will control Gateway IP Network gateway IP address IP IP System IP address MAC MAC address MapDest Dest Dest Lvl Matrix destination remap...

Page 30: ...tail Please note that command availability may vary between firmware series and versions Details of availability are documented for each command 3 11 1 C Command Routers and MSC GCP2U32 only NOTE Superseded by the MtxCfg Command The C command queries the matrix size The response is in the format Dests Srcs Levels Flags1 Flags2 Where Dests is the count of system destinations Srcs is the count of so...

Page 31: ...s assigned via the IP Netmask and Gateway commands A value of 1 enables DHCP and will obtain the values for the IP address Netmask and Gateway from your DHCP server This value is saved and recalled on power up WARNING A DHCP server must be present on your network for this to function properly Using DHCP allows for dynamic IP or fixed IP assignment from a central location the DHCP server Using this...

Page 32: ... echo enable E 0 1 Set matrix echo enable 0 to disable 1 to enable Examples to query and then enable matrix echo E 0 E 1 3 11 5 Firmware Command NOTE Superseded by the sys firmware System Parameter Query the system firmware series and version Example Firmware Pyxis 1 1 7 3 11 6 FrameIP Command NOTE Superseded by the pnl ip System Parameter Query or assign the remote router IP address Usually only ...

Page 33: ...ameter Table for a list of currently defined parameters This command supersedes many individual configuration commands NOTE This command queries Active values of parameters which may differ from values in Stored memory Values in Stored memory are loaded at system startup and can be queried with the GetS Command See System Parameters for more details Command Description Get Display all system param...

Page 34: ...parameter identifier separated by an equals character and the value GetS Parameter Display the Stored value of a single parameter or a subset of parameters under a given parameter node 3 11 10 Help Command Display command reference information 3 11 11 IP Command NOTE Superseded by the net ip System Parameter Query or assign the system IP address This setting is saved and recalled on power up WARNI...

Page 35: ...detection for outputs Format is one decimal number per output 0 Unlocked 1 SD 2 HD Example for a 16x4 system SD HD Unlocked Unlocked LockStatus 1 2 0 0 3 11 13 MAC Command NOTE Superseded by the net mac System Parameter Query system Ethernet MAC address Command Description MAC System Ethernet MAC address in hh hh hh hh hh hh where each hh is a pair of hex digits Example MAC 00 50 C2 8B DF FE 3 11 ...

Page 36: ...tination 2 on the second level The second example queries the mapping for a single destination The third example maps destination 1 to physical destination 5 on all levels The fourth example maps destination 1 to physical destination 6 on the second level only 3 11 15 MapSrc Command Routers only Protocol version 3 0 Query or assign matrix source mappings Source mappings provide a means to remap lo...

Page 37: ...cover what protocol version is in use The returned value is either an integer such as 2 or major and minor version numbers separated by a period such as 2 3 Example MascotVer 2 3 3 11 17 MtxCfg Command Routers and MSC GCP2U32 only Protocol Version 2 0 Query matrix configuration This command replaces the C command and provides the ability to query the matrix dimensions labels current matrix state a...

Page 38: ...y or reclocker disable If an argument is specified 0 7 then a more descriptive JSON structure is returned of the following form newlines and spaces added as a visual aid but are not necessarily part of the response version 1 status STATUS levels name NAME type TYPE destCount DEST_COUNT srcCount SRC_COUNT flags FLAGS destNames NAME NAME srcNames NAME NAME state SRC SRC psetData SRC SRC psetNames NA...

Page 39: ...d to response as a visual aid MtxCfg7 version 1 status OK levels name Level1 type VIDEO destCount 4 srcCount 4 flags mute destNames Dest1 Dest2 Dest3 Dest4 srcNames Src1 Src2 Src3 Src4 state 1 2 3 4 psetData 1 2 3 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 psetNames Startup Preset1 Preset2 Preset3 Preset4 Preset5 Preset6 Preset7 Preset8 Preset9 The example output abo...

Page 40: ... assigning I O grouping MtxGroup 1 1 MtxGroup 2 4 MtxGroup 2 4 The first example MtxGroup command shows that I O grouping is disabled on both levels of a 2 level system The second command configures the system for dual I O grouping on level 1 and quad I O grouping on level 2 On an example 16x16 two level router this would result in an 8x8 matrix on level 1 and a 4x4 matrix on level 2 3 11 19 NetMa...

Page 41: ... preset information which is retained and available through system power cycles Command Description PAdd PRESET DEST SRC Add a connection of SRC to DEST on PRESET for all levels PAdd PRESET DEST SRC LEVEL Add a connection of SRC to DEST LEVEL on PRESET Example PAdd 1 2 3 PAdd 1 3 0 2 The first command adds a connection from Source 3 to Destination 2 in Preset 1 The second command Mutes Destination...

Page 42: ...anel buttons and GPIO pins are specified by numeric ID Panel buttons are numbered beginning with ID number 1 Panel button order depends on the panel but generally has the top left button as button 1 followed by number 2 in the lower left corner number 3 in the top second column continuing to alternate between top and bottom rows till the last button lower right hand corner GPIO auxiliary pins star...

Page 43: ... 1 Enable or disable panel button GPIO command and conditions 0 disable 1 enable Examples for querying and enabling panel command conditions PanelCmdEn 0 PanelCmdEn 1 3 11 25 PanelCond Command Protocol Version 3 0 Query and assign panel button GPIO status and indicator conditions Panel button GPIO conditions are a counterpart to Panel Commands and provide a means to easily implement custom status ...

Page 44: ...g Examples PanelCond 1 P0 2 P1 67 P0 PanelCond 1 1 P0 PanelCond 68 P1 PanelCond 68 The first example above queries the currently assigned panel GPIO conditions which shows that button number 1 and 2 have P0 and P1 conditions assigned respectively which lights the button LEDs when the current matrix routing matches preset 0 or preset 1 respectively and GPIO pin 3 GPIO pins start at 65 will output a...

Page 45: ... PanelExtEn 1 The first command queries the current external panel interface setting 0 disabled The second command enables the external panel interface 3 11 28 PanelRate Command Protocol Version 2 1 For changing remote button panel refresh rate When a button panel is configured to control a remote router the current connection status is refreshed at regular intervals This command can be used to in...

Page 46: ...tl serial2 proto System Parameters Query or assign the serial protocol The only available option is currently the case insensitive value Mascot however additional control protocols may be added in the future Value is stored and recalled on power up Command Description ProtoSer Query the protocol used on the serial port ProtoSer PROTO Assign the protocol used on the serial port the only valid value...

Page 47: ...s command changes preset data which is stored and persists through power cycles Command Description PSub PRESET DEST Remove any existing connection to DEST in PRESET for any level PSub PRESET DEST LEVEL Remove any existing connection to DEST LEVEL in PRESET Example PSub 1 2 PSub 1 3 2 The first command removes any connection to Destination 2 in Preset 1 The second command removes any connection to...

Page 48: ... 3 11 34 Reboot Command Instructs the system to reboot which is done after a brief delay Ensures that all outstanding data writes are written to non volatile memory prior to the reboot 3 11 35 ReclkDis Command Routers only Protocol Version 2 1 Command for disabling or enabling SDI reclockers Not all router systems support this option Value is saved and recalled on power up Command Description Recl...

Page 49: ...the final command sets the IP address of the router to sync secondary router 3 11 37 S Command Routers and MSC GCP2U32 only Query the current matrix routing state Source values for all levels of every destination are shown This command without an argument is equivalent to the X Command with no arguments If an argument value of 1 is supplied then the matrix state is displayed with labels The state ...

Page 50: ...and or Stored parameter values Behavior depends on the parameter and is defined in the System Parameter Table Values in Stored memory are loaded at system startup See System Parameters for more details Command Description Set List all parameter identifiers which can be set one per line Set Parameter Value Set a parameter s Active and or Stored value depends on parameter Examples of listing all wri...

Page 51: ... system parameter Stored values only Values set with this command will not take effect until the system is restarted NOTE Some parameters may not be assignable in Stored memory for example if it does not make sense to recall a value on start up See System Parameters for more details Command Description SetS List all parameter identifiers which can be set in Stored memory one per line SetS Paramete...

Page 52: ...st level label should be used 3 11 43 SysName Command NOTE Superseded by the sys name System Parameter Query or assign system name The system name is provided for convenience when managing multiple Matrix Switch Corporation systems This value is stored and recalled on power up Command Description SysName Query system name SysName STR Set system name up to 15 characters Example for querying and ass...

Page 53: ... system with older firmware not supporting the SysType command the second example is what might be returned by an MSC GCP2U32 LCD panel 3 11 45 Vars Command Protocol Version 2 3 Display all system configuration variables Useful in serial terminal or telnet sessions to view all configuration values Command Description Vars Display all system configuration parameters Note that variables consisting o...

Page 54: ...W PRESET Write current matrix routing state to PRESET Example to save state to preset 1 W 1 3 11 47 WebPass Command Assign a web password to password protect the web page interface The serial and TCP IP port Mascot protocol control is not protected by this password This value is stored and recalled on power up Command Description WebPass STR Set web page password blank to disable Examples of setti...

Page 55: ... can be used for SRC to Mute a destination if supported for a given level Examples X 1 1 2 2 3 8 0 4 X 3 3 8 X 3 4 X 4 0 2 In the above examples the first command queries the matrix routing state typical of a 16x4 system for example the second command queries destination 3 only the third command connects source 4 to destination 3 on all levels and the fourth command mutes destination 4 level 2 Com...

Page 56: ...e image has been transferred to the device s FLASH storage area 5 The device will automatically reboot to perform the remainder of the software update during which the web page interface may display a connection error which can be ignored 6 The software update may take an additional minute to complete and power should not be disconnected during this time 7 Reload the web page interface by holding ...

Page 57: ... to the IP address 192 168 2 59 Consult the TFTP Software section for details 4 3 TFTP Software There are many different options for TFTP client programs the choice of which depends on what operating system you are using on the computer being used to perform the TFTP transfer from The following sections list some options for various operating systems 4 3 1 Windows Windows XP has a TFTP client inst...

Page 58: ...y put MSC Pyxis Firmware x x x img 6 Make sure to replace MSC Pyxis Firmware x x x img with the correct version number of the file 7 Pressing ENTER after the put command will initiate the TFTP transfer Make sure to perform the necessary actions to prepare the system for an update prior to attempting the transfer 8 The TFTP program will indicate if the transfer was successful or not 9 If the transf...

Page 59: ...e TFTP transfer binary put MSC Pyxis Firmware x x x img 6 Make sure to replace MSC Pyxis Firmware x x x img with the correct version number of the file 7 Pressing ENTER after the put command will initiate the TFTP transfer Make sure to perform the necessary actions to prepare the system for an update prior to attempting the transfer 8 The TFTP program will indicate if the transfer was successful o...

Page 60: ... running A computer system can then be configured with an IP address on the same IP subnet and the webpage configuration can be loaded for viewing and changing the IP address as described in the section Accessing The Web Page Interface The device will remain at the default IP address until rebooted at which point it will revert to the assigned network settings 5 2 Unexpected reboots If the device ...

Page 61: ...Deg C Operating Temp 0 Through 75 Deg C Humidity 0 Through 90 Non Condensing Warranty 2 Years Parts Labor SDI Video Connector type BNC Data Types SMPTE 259M 292M 424M Data Rates 19 Mbit s through 3 0 Gbit s Re clocking Data Rates 270 Mbit s 1 485 Gbit s 2 97 Gbit s Input Output Return Loss 15dB HD 12dB 3G Input Level 800 mV P P 20 Input Impedance 75 Ohms 1 Cable equalization 1694A coax 400m SD 140...

Page 62: ... more RS 485 connected devices Pin Name Function 1 4 6 7 NC Not Connected 2 TX RS 232 Transmit 3 RX RS 232 Receive 8 D RS 485 Data Positive 9 D RS 485 Data Negative 5 GND Ground DE 9 Pin Numbers 6 3 GPIO Auxiliary Interface A GPIO General Purpose I O auxiliary interface is provided on a female DB 25 connector and provides additional control and status functionality Page 62 of 64 2013 2018 Matrix S...

Page 63: ... means it is silenced Output Synonymous with Destination Preset Matrix Switch Corporation Router devices provide 10 presets which store matrix Routing connections When a preset is recalled zero or more matrix connections are changed based on the content of the Preset Numbered starting from 0 Preset 0 is special in that it is recalled on system startup Remote Panel Matrix Switch Corporation Remote ...

Page 64: ... which shall be placed on the outside of the shipping package 6 This warranty does not apply if the product has been damaged by accident abuse misuse misapplication or modification EXCEPT AS SET FORTH ABOVE NO OTHER WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MSC EXPRESSLY DISCLAIMS ALL EXPRESS OR IM...

Reviews: