Page 4: ...le every precaution has been taken in the preparation of this system manual Matrix Comsec assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained herein Neither Matrix Comsec nor its affiliates shall be liable to the purchaser of this product or third parties for damages losses costs or expenses incurred by ...

Page 5: ...1 GFX11E 17 FXS Port Parameters 19 Mobile Port Parameters 23 Mobile Network Selection 27 Signal Strength 30 Passwords 31 Reinstate the Default Settings 33 Restart the System 34 Software Version and Revision Display 35 Features of SIMADO GFX11 GFX11E 37 Allowed Denied Numbers 37 Automatic Number Translation 39 Battery Back up during Power Failure 42 Call Divert 44 Call Duration Display 46 Call Prog...

Page 6: ...rity Code 65 Service Provider Lock 66 Short Messaging Services SMS 67 Appendix 69 Acronyms 69 Features at Glance 70 Product Specifications of SIMADO GFX11 GFX11E 71 System Commands 74 Warranty Statement 76 Regulatory Information 77 Index 79 ...

Page 7: ...Engineers SE Persons who install configure and maintain SIMADO GFX11 GFX11E It is assumed that they have some experience in installing and configuring GSM Fixed Cellular Terminals FCT System Engineer has full access to the system System Administrators SA Persons who operate the system and perform administrative functions System Administrator has limited access to the system Users Persons who actua...

Page 8: ...t parameters and features are presented in the following format To configure Answer Signaling on the FXS Port dial 221 Answer Signal Where Answer Signal is 0 for None 1 for Polarity Reversal Default Polarity Reversal This is an instruction to configure Answer Signaling on the FXS Port along with the default value You must dial the digits and characters in the command string in a continuous sequenc...

Page 9: ...the terms used in this System Manual are defined below System Engineers SE Persons who install configure and maintain SIMADO GFX11 GFX11E System Administrators SA Persons who operate the system and perform administrative functions Users Persons who uses SIMADO GFX11 GFX11E Caller Calling party The person who make calls Called party The person to whom the call is made Using this System Manual we ho...

Page 10: ...4 Matrix SIMADO GFX11 System Manual ...

Page 11: ... GFX11 is interfaced with the PBX all the incoming calls on the Mobile Port of SIMADO GFX11 can be routed to the desired extension of the PBX Similarly all the outgoing calls made to the mobile phones can be routed through the Mobile Port of SIMADO GFX11 reducing the telecommunication cost of the organization SIMADO GFX11 is available in two configurations SIMADO GFX11 2G 3G SIMADO GFX11E 2G 3G SI...

Page 12: ...ring on the ports including errors SIMADO GFX11E Port Name Connector Description ANTENNA SMA Female To connect the Antenna for the Mobile Ports SIM Card Slot To insert a SIM Card for mobile connectivity 12VDC 1 25A Max DC Jack To connect a Power Adapter FXS RJ11 To connect a standard telephone instrument or a PBX PWR Power RDY SIM FXS FXS Port NW Network SIM Card Slot DC Power Jack FXS Port Antenn...

Page 13: ...curring on the ports including errors Port Name Connector Description ANTENNA SMA Female To connect the Antenna for the Mobile Ports SIM Card Slot To insert a SIM Card for mobile connectivity 12VDC 1 25A Max DC Jack To connect a Power Adapter ON OFF Button To switch on or switch off the SIMADO GFX11E FXS RJ11 To connect a standard telephone instrument or a PBX PWR Power RDY SIM FXS FXS Port NW Net...

Page 14: ...8 Matrix SIMADO GFX11 System Manual Applications of SIMADO GFX11 GFX11E Case 1 Standalone Case 2 SIMADO GFX11 interfaced with a PBX SIMADO GFX11 GSM 3G PBX SIMADO GFX11 GSM 3G ...

Page 15: ...Matrix SIMADO GFX11 System Manual 9 Case 3 SIMADO GFX11E in Elevator Emergency Application GSM 3G Service Center please help I am stuck SIMADO GFX11E 1 2 3 4 5 6 ...

Page 16: ...10 Matrix SIMADO GFX11 System Manual ...

Page 17: ...ic shock and injury to yourself and others Do not install the system at any of the locations listed below in any area where it is directly exposed to sunlight excessive cold humidity corrosive fumes at the place where shocks or vibrations are frequent or strong at the place where it comes in contact with dust and oil near any water source or water body like a wash bowl kitchen sink bath tub or nea...

Page 18: ...s are advised to maintain appropriate distance from the system They are also advised to avoid being in the vicinity of the product for a long time Battery1 SIMADO GFX11E has a NI MH AAA 7 2V 800mA battery Do not disassemble weld burn or throw the battery into waste This battery may explode and cause serious injuries Dispose off the used batteries according to the local regulations If required the ...

Page 19: ...nal strength To the FXS Port connect a standard single line telephone using a standard telephone cable with RJ11 plugs You may also connect the FXS Port of SIMADO GFX11 to a PBX Insert SIM Card of the service provider in the SIM Card Slot of SIMADO GFX11 03 Power Adapter 12V 2A 1 04 Line Cord RJ11 1 05 Wall Mounting Template 1 06 M7 30 Screw 2 07 Screw Grip 2 08 Warranty Card Set 1 09 SIMADO GFX11...

Page 20: ...otection insert the SIM Card in the mobile handset and disable PIN protection Remove the SIM Card from the mobile handset and insert it in the Mobile Port s SIM holder You can change the SIM PIN to the desired value while configuring the system For instructions on changing the SIM PIN refer Mobile Port Parameters Screw the antenna on to the Antenna Connector of SIMADO GFX11 SIMADO GFX11E Select an...

Page 21: ...ctions on changing the SIM PIN refer Mobile Port Parameters Screw the antenna on to the Antenna Connector of SIMADO GFX11E Powering ON SIMADO GFX11 GFX11E Connect the Power Adapter into the Power Jack and plug it into a power outlet Switch ON the power supply Also press the ON OFF button2 to switch on your SIMADO GFX11E As soon as SIMADO GFX11E is powered on the battery will also start charging Se...

Page 22: ...eech with the caller Replace the receiver to disconnect the call SIMADO GFX11 GFX11E is supplied with factory default settings You can use the system with these settings or configure it according to your requirement See Configuring SIMADO GFX11 GFX11E for instructions LED Activity Indication PWR ON SIMADO GFX11 is power On Off SIMADO GFX11 is power Off RDY ON SIM Card is present and active Off SIM...

Page 23: ...ystem and you can configure and use all the features of the system The System Engineer mode is protected by a password referred to as SE password To configure SIMADO GFX11 from SE mode Lift the receiver of the telephone connected to SIMADO GFX11 To enter SE mode dial 19 SE Password The default SE Password is 1234 Dial the command string To exit SE mode dial 00 Replace the receiver of the telephone...

Page 24: ...DO GFX11 To enter SA mode dial 18 SA Password The default SA Password is 1111 Dial the command string To exit SA mode dial 00 Replace the receiver of the telephone While dialing command strings you must dial the digits and characters in a continuous sequence For example to enter SA Mode you must dial the command string as 181111 While configuring the system if there is an incoming call on the FXS ...

Page 25: ... as CLI Type if the telephone instrument connected to the FXS Port does not have a display Gain for CLI Generation You may configure the gain for CLI generation if you have configured the CLI Type as FSK and need to adjust the gain for generating CLI To configure the gain for CLI generation dial 223 Gain Where Gain is 1 for 0dB 2 for 1 5dB 3 for 3 0dB 4 for 4 5dB 5 for 6 0dB 6 for 7 5dB 7 for 9 0d...

Page 26: ...d of Dialing digit dial 110 1 To remove as End of Dialing digit dial 110 0 Default is used as end of dialing digit Replacing by DTMF digits in CLI The GSM network presents the calling party number with the prefix to the called party However not all equipments can present the calling party number containing SIMADO GFX11 enables you to remove the prefix and replace it with an appropriate number stri...

Page 27: ...n configure either None or Polarity Reversal as Answer Signal on the FXS Port None is configured when no answer signaling is to be generated and Polarity Reversal is configured when it is to be generated in the form of Polarity Reversal To configure answer signaling on FXS Port dial 221 Answer Signal Where Answer Signal is 0 for None 1 for Polarity Reversal Default Polarity Reversal Disconnect Sig...

Page 28: ...ure Open Loop Disconnect Timer on FXS Port dial 249 Open Loop Disconnect Timer Where Open Loop Disconnect Timer is from 001 to 999 ms Default 500 ms No Dial Tone on FXS Port You may enable or disable the dial tone on the FXS Port when SIMADO GFX11 is not registered with the network To enable or disable the dial tone on the FXS Port dial 103 No Tone when system not registered Where No Tone when sys...

Page 29: ...e current SIM PIN dial 113 New SIM PIN Where New SIM PIN can be of minimum 4 and maximum 6 digits Accepted digits are 0 to 9 Default 1234 The SIM PIN is not set to default or changed when you Reinstate the Default Settings Your SIM Card is Locked If you have enabled PIN protection on your SIM Card your SIM Card may get blocked if you enter the wrong SIM PIN thrice To unblock your SIM Card you will...

Page 30: ...Transmit Gain Where Transmit Gain is 1 for Very low 2 for Low 3 for Normal 4 for High 5 for Very High Default Normal To set the transmit gain of the Mobile Port to the default value dial 272 0 Pause Timer Pause timer is the time for which SIMADO GFX11 will wait while dialing out DTMF digits on the Mobile Port when the character P is detected in the DTMF number string The Pause Timer is used for Mu...

Page 31: ...s default ON time of the module 70 ms and 001 to 255 means DTMF Out Dial ON Time 100 ms i e from 100 ms to 25500 ms Default 100 milliseconds You may exit the SE Mode or continue with the system configuration Registered Network Display You can view the network with which the GSM module is currently registered with on the display of the telephone connected to the FXS Port Make sure that the telephon...

Page 32: ...26 Matrix SIMADO GFX11 System Manual When CLI Type is set as FSK the Registration Status display format would be as follows 0001 GSM ...

Page 33: ...n on the expiry of the Network Registration Retry Timer If no match is found the Mobile Port SIM will not get registered with any of the available network operators and no calls can be made or received on this port Enter SE Mode To configure network selection mode for the Mobile Port dial 331 Network Selection Mode Where Network Selection Mode is 1 for Automatic 2 for Manual Default Automatic To c...

Page 34: ...the system configuration Preferred Network Mode When 3G Mobile Port is used in the SIMADO GFX11 GFX11E the SIM gets registered with either GSM 2G or UMTS 3G network whichever is available You can select the Network with which the SIM should be registered by setting the Preferred Network Mode If the SIM you have installed in the 3G Mobile Port supports both GSM and UMTS services but you want it to ...

Page 35: ...ode To configure Preferred Network Mode for the Mobile Port dial 334 Preferred Network Mode Where Preferred Network Mode is 1 for Any GSM UMTS 2 for GSM only 3 for UMTS only Default Any GSM UMTS Exit SE Mode or continue with the system configuration ...

Page 36: ... Signal Strength follow the steps given below Go Off Hook Dial 11 You will get confirmation tone Go On Hook Signal strength will be displayed on the LCD of your telephone Go Off Hook again you will get dial tone When FSK CLI is set on the FXS Port of SIMADO GFX11 the signal strength will be displayed as under The numbers indicate the strength of the network When network signal strength is high the...

Page 37: ... continue with the system configuration System Administrator SA Password The System Administrator level is protected by the password called SA password The default SA password is 1111 You can change the default SA password to the desired value Enter SE SA Mode To change SA Password dial 108 New SA Password Where New SA Password can be of maximum four digits Accepted digits are from 0 to 9 Default ...

Page 38: ... SE SA Mode or continue with the system configuration If you forget the SA password you can change it to the desired value by entering SE Mode and dialing the same command string 108 New SA Password Exit SE Mode after changing the SA password ...

Page 39: ...ettings in the system if needed When you reinstate the default settings all parameters except the following will be set to factory defaults Call Divert Call Progress Tones Ring Type SIM PIN value Restoring Default Settings Enter SE Mode To default SIMADO GFX11 dial 106 Reverse SE Password Reverse SE password is a number string of maximum 4 digits For example if your SE Password is 1234 you need to...

Page 40: ...O GFX11 by dialing a command from the phone connected to its FXS Port instead of switching off and switching on the system Enter SE Mode To restart SIMADO GFX11 dial 105 SE Password Where SE Password is a number string of four digits and acceptable digits are 0 to 9 Exit SE Mode ...

Page 41: ...ing the CLI Type see FXS Port Parameters How to view Software Version Revision Enter SE Mode To view current software version revision of SIMADO GFX11 dial 109 You will get confirmation tone Go On Hook Version Revision of the software will be displayed on the LCD of your telephone When the CLI type set on the FXS Port is FSK the format of display would be as under Where VV XX Software Version and ...

Page 42: ...36 Matrix SIMADO GFX11 System Manual ...

Page 43: ... five numbers in each list When you configure the Allowed and Denied Number Lists for each number dialed from the FXS Port SIMADO GFX11 will use the best match found logic to compare the dialed number string with the numbers configured in the Allowed Number List and the Denied Number List The system will allow the number to be dialed if the dialed number matches with both lists matches with Allowe...

Page 44: ...r list dial 261 Location Index Where Location Index is from 1 to 5 To clear all the entries from allowed number list dial 261 0 To configure numbers in the denied number list dial 262 Location Index Number Where Location index is from 1 to 5 Number can be of maximum 16 digits and only digits 0 to 9 are allowed Default Blank To clear an entry from denied number list dial 262 Location Index Where Lo...

Page 45: ...ng the best match found logic If a match is found SIMADO GFX11 will dial out the Substitute number string configured for the dialed number string in the ANT table Let us understand this feature with the help of an example A user dials 952652631721 from the telephone connected to the FXS Port out of habit SIMADO GFX11 routes this call through the Mobile Port to the desired destination However the G...

Page 46: ...r Speed Dialing You can configure short codes for number strings that you frequently dial as Dialed Number Strings and the complete number strings that should be dialed out in place of the short code as the Substitute Number Strings How to configure Enter SE Mode To configure the Dialed Number String dial 291 Number Index Dialed Number String Where Number Index is from 1 to 6 Dialed Number String ...

Page 47: ...ute Number String can be of maximum 8 characters Acceptable digits and characters are 0 9 A B C D F P and If you are configuring DTMF Digits and characters refer the table given in the previous command for the codes for each DTMF digit Default Blank To clear the Substitute Number String dial 292 Number Index To configure the Calling Card Service Number Index dial 293 Number Index Calling Card Serv...

Page 48: ...ystem is working on battery or on external power supply through the LED indication When there is a power failure SIMADO GFX11E will start operating on battery It will send an alert SMS Operating on Battery to the pre programmed numbers immediately Similarly it will send an alert SMS Low Battery to the pre programmed numbers when the system is working on battery and low battery is detected Alert me...

Page 49: ...umber Where Number Index is from 1 and 2 Emergency number can be of maximum 16 digits Acceptable digits are 0 to 9 Default Blank The number will be stored at the Index you dialed To clear the Emergency Contact Number at an index dial 351 Number Index Where Number Index is from 1 and 2 The number stored at the dialed Index will be cleared Exit SE Mode ...

Page 50: ...ted to the desired destination number if the FXS Port does not answer the call Call Divert When SIMADO GFX11 is Off or there is no coverage All incoming calls on the Mobile Port are diverted to the desired destination number if SIMADO GFX11 is switched off or there is no network coverage You can select the type of Call Divert you want to use and configure the desired destination number How to conf...

Page 51: ...Matrix SIMADO GFX11 System Manual 45 Exit SE SA Mode You cannot set more than one type of call divert at a time ...

Page 52: ...Type see FXS Port Parameters How to view Call Duration You can view Call Duration from the SE mode as well as from the SA mode Enter SE SA Mode To view the duration of the desired call type dial 610 Call Type Where Call Type is 1 for Last Call 2 for All Received Calls 3 for All Dialed Calls 4 for All Calls If CLI type set on the FXS Port is FSK the format of call display would be as under Where N ...

Page 53: ...d be as under Where N is the Type of Call HHMMSS stands for Hours Minutes Seconds For Example Call duration display of last incoming call of 30 seconds will be displayed as shown below To clear all call duration display dial 610 0 Exit SE SA Mode If the total call duration exceeds 99 59 59 call duration will reset to 00 00 00 1 000030 IC DUR 00 00 30 N HHMMSS N Meaning 1 Last Call may be an incomi...

Page 54: ... Code Country Dial Tone Busy Tone Error Tone Ring Back Tone Freq Cadence Freq Cadence Freq Cadence Freq Cadence Hz second Hz second Hz second Hz second 01 Australia 425 25 cont 425 0 375on 0 375off 425 0 375on 0 375off 425 1 0 on 4 0off 02 Argentina 425 cont 425 0 3on 0 2off 425 0 3on 0 4off 425 1 0 on 4 0off 03 Belgium 425 cont 425 0 5on 0 5off 425 0 167on 0 167off 425 1 0 on 4 0off 04 Brazil 425...

Page 55: ... 1 0 on 4 0off 23 Portugal 425 cont 425 0 5on 0 5off 450 0 33on 1 0off 450 1 0 on 4 0off 24 Russia 425 cont 425 0 4on 0 4off 425 0 25on 0 25off 425 1 0 on 4 0off 25 Saudi Arabia 425 cont 425 0 5on 0 5off 425 0 25on 0 25off 425 1 0 on 4 0off 26 Singapore 425 cont 425 0 75on 0 75off 425 0 25on 0 25off 425 1 0 on 4 0off 27 South Africa 400 33 cont 400 0 5on 0 5off 400 0 25on 0 25off 400 1 0 on 4 0off...

Page 56: ...gium dial 104 03 Exit SE Mode In above table refers to modulation of two frequencies f1 and f2 and refers to addition of two frequencies Cont is abbreviation for continuous Confirmation tone for all countries is 400Hz 0 1 on 0 1 off Programming tone for all countries is 400Hz 0 1 on 0 9 off ...

Page 57: ...ls using CLIR This is Service Provider dependant feature To use this feature you must get CLIR facility activated by your service provider How to configure Only SE can configure CLIR Enter SE Mode To enable disable CLIR on the Mobile Port dial 202 Code Where Code is 0 for Disable 1 for Enable Default Disabled Exit SE Mode Some networks do not allow outgoing calls when CLIR is activated So check wi...

Page 58: ...ed number matches with an Emergency Number in the table SIMADO GFX11 will not check the Allowed and Denied Number Lists or the Automatic Number Translation Table It will dial out the number In System Firmware Version V4 and earlier the GSM module supports certain fixed Emergency Numbers You can configure only the number supported by the module in the Emergency Number Table If you configure a numbe...

Page 59: ...onfigured as follows The default Emergency Number Table for Italy is configured as shown as follows The Emergency Number you want to add to the table must be stored at Index that is editable You can add numbers at Index 1 and 2 only To configure the Emergency Number Table Enter SE Mode To add an emergency number dial 151 Index Emergency Number Where Index is 1 and 2 Emergency number can be of maxi...

Page 60: ...54 Matrix SIMADO GFX11 System Manual To clear the emergency number at an index dial 151 Index Where Index is 1 and 2 The number stored at the Index you dialed will be cleared Exit SE Mode ...

Page 61: ...ly You set Hotline for this number and set the Hotline Delay Timer to 3 seconds Whenever you go Off Hook SIMADO GFX11 will play dial tone and wait for 3 seconds If you do not dial any digit during the Hotline Delay Timer SIMADO GFX11 dials the hotline number 2654227 When the called person answers the call you get connected However if you dial a number before the Hotline Delay Timer expires SIMADO ...

Page 62: ...f the IMEI code is registered in the White list of EIR This number is useful in case SIMADO GFX11 is lost or stolen The network operator can block the IMEI number of the GSM module installed in the system Thus the important information stored in the system can be protected from misuse The currently used Structure of IMEI number is as follows AA BBBBBB CCCCCC D Where AA is Reporting Body Identifier...

Page 63: ...this feature enabled by your service provider Configure the CLI Type on the FXS Port as FSK How to configure Enter SE Mode To enable disable location information indication on the Mobile Port dial 205 Flag Where Flag is 0 for OFF 1 for ON Default OFF Exit SE Mode How to view Location Information To view the Location Information on your telephone follow the steps given below Go Off Hook Dial 12 You...

Page 64: ...he calling card service provider for example 113212 Some service providers also prompt the users to select a language before navigating further in the menu After dialing the PIN number users can dial the number they want to call for example 0014125126508 Thus when using a calling card users must dial a very lengthy number string each time they need to make a call using the calling card The use of ...

Page 65: ...dialed by the user matches with the Dialed Number String in the table the system checks the Calling Card Number Services Number Index It fetches the number configured for this index in the Calling Card Services Number Table The system dials out this number After that the system checks the Calling Card Password Index in the ANT table It fetches the number configured for this index in the Calling Ca...

Page 66: ...or DID DISA mode you must configure the following parameters in SIMADO GFX11 at location A the PCO Calling Card Service Number table Calling Card Password table Automatic Number Translation table Call Proceeding Tone a The mobile number of GSM Port of PBX at location B should be configured at an index in the Calling Card Service Number table The DISA login code Extension Number Extension Password ...

Page 67: ...twork Tone is set SIMADO GFX11 will check the ANT table Since Substitute Number String is same as Dialed Number String no number translation will take place Next the system will check the Calling Card Services Number Index and fetch the mobile number of the GSM Port of the PBX at location which is configured in the Calling Card services Number table The system will make a call to this mobile numbe...

Page 68: ...Number string is 16 The system considers each DTMF character see above table that you include in the Number string as two digits So DTMF characters you include in the Number String will use up more digit length than the numeric DTMF digits To clear the Calling Card Number Services Number String from the table dial 341 Number Index To configure the Calling Card Password dial 342 Number Index Callin...

Page 69: ...dialing out the DTMF digits on the Mobile Port dial 241 DTMF Out Dial ON Time Where DTMF Out Dial ON Time is from 000 to 255 000 means default ON time of the module 70 ms and 001 to 255 means DTMF Out Dial ON Time 100 ms i e from 100 ms to 25500 ms Default 100 milliseconds As the detection of DTMF digits received over GSM network is not perfect the performance of this feature is likely to be affec...

Page 70: ...le To configure Ring Type for China dial 311 03 Exit SE mode Ring Type Code Country Frequency Hz CADENCE In Seconds ON 1 OFF 1 ON 2 OFF 2 01 Australia 25 0 4 0 2 0 4 2 0 02 Brazil 25 1 0 4 0 03 China 25 1 0 3 0 04 Egypt 25 2 0 4 0 05 France 25 1 5 3 5 06 Germany 25 3 5 5 5 0 79 1 1 07 Greece 25 1 0 4 0 08 India 25 0 4 0 2 0 4 2 0 09 Israel 25 2 0 3 0 10 Italy 25 1 0 4 0 11 Japan 25 1 0 2 0 12 Kore...

Page 71: ...ing in the ANT table and keep the corresponding Substitute Number String blank For instructions see Automatic Number Translation How to configure Enter SE mode To configure the security code dial 121 Security Code Where Security Code number can be of maximum 8 digits Allowed digits are 0 to 9 A B C and D Default Blank If you are configuring DTMF digits and characters in the number string dial the ...

Page 72: ...SIM Card is inserted in the system How to configure Enter SE Mode To change service provider password dial 702 Old Service Provider Password New Service Provider Password Where Old Service Provider Password is of four digits Acceptable digits are 0 to 9 New Service Provider Password is of four digits Acceptable digits are 0 to 9 Default Service Provider Password 1234 To Lock Unlock the system with...

Page 73: ...dial 203 Flag Where Flag is 0 for Disable 1 for Enable Default Disabled Exit SE Mode How to Read the message Lift the receiver of telephone connected to SIMADO GFX11 Dial 21 Index Index is the location where the SMS is stored Index is from 001 to xxx where xxx is the maximum SMS capacity of the SIM Card For example if the SIM Card can store maximum 100 messages then range of index will be 001 to 1...

Page 74: ...68 Matrix SIMADO GFX11 System Manual Message at the indicated index will be deleted Read messages are deleted one by one index wise ...

Page 75: ...a Transmit FXS Foreign Exchange Subscriber GSM Global System for Mobile Communication IMEI International Mobile Equipment Identity ITU International Telecommunication Union LED Light Emitting Diodes MCC Mobile Country Code MNC Mobile Network Code ms milliseconds PBX Private Branch Exchange PIN Personal Identification Number PSTN Public Switched Telephone Network SA System Administrator SE System E...

Page 76: ...the Location Information 12 03 To know the IMEI code 13 04 To know the current network with which the GSM Module is registered 14 05 To enter into SA mode 18 SA Password 06 To enter into SE mode 19 SE Password 07 To exit SE SA mode 00 08 Reading SMS using telephone instrument 21 Index 09 Deleting SMS using telephone instrument 22 Index ...

Page 77: ...on Power Class 4 2W at GSM850 EGSM900 MHz band Class 1 1W at DCS1800 PCS1900 MHz band Class 3 0 25W at WCDMA 850 1900 2100 RF Sensitivity Better than 102dBm at GSM 850 EGSM900 PCS1900 Better than 106dBm at WCDMA850 Better than 108dBm at WCDMA1900 2100 Speech Gain Transmit and Receive Configurable Antenna Type Fixed Omni Directional Swivel Antenna Antenna Gain Dipole 1 8 2 5 dBi Antenna Connector S...

Page 78: ...er voltage Secondary protection Internal Battery NI MH AAA 7 2V 800mA 8 Applicable for SIMADO GFX11E only Supply Input 12VDC 1 25A actual consumption External Adaptor 100 240VAC 47 63HZ supplied by Matrix Power Consumption 5W Typical Connector Casio DC power Jack LED Indications Battery BAT a Power Supply PWR Network NW SIM RDY FXS Port FXS a Applicable only for SIMADO GFX11E Dimensions WxHxD 13 3...

Page 79: ...MADO GFX11 System Manual 73 Operational Conditions Storage Conditions Temperature 0 C to 45 C 34 F to 113 F Humidity 5 95 RH non condensing Temperature 40 C to 85 C 40 F to 185 F Humidity 0 95 RH non condensing ...

Page 80: ... Enable Disable CLIR on Mobile Port 202 Mode To Enable Disable Incoming SMS notification on Mobile Port 203 Flag To Enable Disable the Location Information Indication 205 Flag To configure the answer signal to be generated on FXS Port 221 Answer Signal To configure FXS Port CLI Type 222 CLI Type To configure the gain for CLI generation on the FXS Port 223 Gain To configure First Digit Wait Timer 2...

Page 81: ...dex 341 Number Index To configure the Calling Card Password table 342 Number Index Calling Card Password Number String To clear the particular Calling Card Password index 342 Number Index To configure the digit which will be replaced with in the CLI 301 Number String To clear the digit configured 301 To select the country for ring type of incoming call 311 Code To configure Mobile Network Selectio...

Page 82: ...ns 3 If the product is subjected to abuse damage misuse neglect fire power flow acts of God accident 4 If the product is installed or used in combination or in assembly with the products that are not supplied or authorized by Matrix or are of inferior quality or design than Matrix supplied products which may cause reduction or degradation in functionality 5 If the product is operated outside the p...

Page 83: ...Matrix SIMADO GFX11 System Manual 77 Regulatory Information ...

Page 84: ...78 Matrix SIMADO GFX11 System Manual ...

Page 85: ...ty 3 Calling Line Identification Restriction CLIR 51 Caution 2 Check IMEI code 56 CLI Type 19 23 Configuring SIMADO GFX11 17 System Engineer Level SE 17 Connecting SIMADO GFX11 13 Country Code 21 CPT Code 48 D Disconnect Signaling on FXS Port 21 DTMF Out Dial ON Time 25 DTMF Outdial Option 25 E Emergency Number Dialing 52 End of Dialing 20 F Features at Glance 70 First Digit Wait Timer 19 FXS Port...

Page 86: ... Powering ON SIMADO GFX11 15 Preferred Network Mode 28 Product Specifications 71 Protect SIMADO GFX11 and Yourself 11 Pseudo Network Tone 61 R Receive Gain 24 Registered Network Display 25 Regulatory Information 77 Remove Country Code from CLIP 20 Replacing by DTMF digits in CLI 20 Restart SIMADO GFX11 34 Restoring Default Settings 33 RF Safety 12 Ring Type 64 S Security Code 65 Service Provider L...

Page 87: ......

Page 88: ...90010 India Tel 91 265 2630555 Fax 91 265 2636598 E mail Info MatrixComSec com Manufacturing Unit 19 GIDC Waghodia 391760 Dist Vadodara India Tel 91 2668 263172 73 Customer Care Tel 91 265 2630555 E mail Customer Care MatrixComSec com Support MatrixComSec com www MatrixComSec com ...