8-BUTTON COUNTDOWN
IN-WALL TIMER WITH
REPEATING FUNCTION
Please keep this instruction
!
WARNING
: Timer will control devices from one location. Do not use
in a 3-Way application where multiple switches control the same
device.
: This wire that must be available in the Junction Box
Timer will not function properly if a neutral wire is not available in the
wall box.
: This timer is only intended to be permanently installed
into an electrical wall box.
To avoid fire, shock, or death, turn off power at circuit breaker or the
fuse box before wiring.
Installation by a licensed electrician to local, state and national codes
is recommended.
For indoor use only.
Do not exceed electrical ratings.
INSTALLATION
1. Turn off power at circuit breaker or fuse box
2. Remove existing wall plate and switch from wall box.
3. Make sure the following 3 wires are present in the wall box.
If these are not present, this Timing Device will not function properly.
Additional wiring to the wall box will be required before installation of
this timer can be completed.
a. 1 Hot Wire from circuit breaker box
b. 1 Load Wire to the device to be powered
c. 1 Neutral Wire
5. Use the included wire nuts
and securely twist the wires
together as indicated in the
wiring Diagram.
4. Strip wires 1/2-inch long.
From Timer In Wall Box
Black Wire ----------- Hot Wire
Red Wire ----------- Load Wire
White Wire ----------- Neutral Wire
Green Wire ----------- Ground Wire*
*or to ground post or screw terminal
PRODUCTS VIEW
1
2
3
There are 8 buttons on the main panel: 6 countdown buttons, an
ON/OFF button and a REPEAT button.
Configuration of the countdown buttons:
1Min, 5Min, 10Min, 20Min, 30Min, 60Min
1
Countdown Program Button
: Press to start a countdown program.
2
3
ON/OFF Button
: Manually turn ON/OFF or override a running program.
24-Hr Repeat Button:
:
Activate or deactivate the daily repeat of a
program.
TECHNICAL SPECIFICATIONS
125V~,60Hz
15A/1875W Resistive, 10A/1250W Tungsten,
10A/1250W Ballast, 1/2HP, TV-5
Operating temperature: 5
-
122 (-15
-
50 )
Storage temperature: -4
-
140
(-20
-
60 )
Insulation class: II
Protection class: IP20
24H Repeat accuracy:
±
2 minutes/month
MEW-PT1850
Installation Instructions
MEW-PT1850
Single Pole
Neutral Wire
Direct Wire
WARNING
Disconnect power to the mounting box by turning OFF the circuit
breaker or removing the fuse for the circuit before installing the
MEW-PT1850, replacing Lamps, or doing any electrical work.
Wiring