Installation- and Operational Instructions
for ROBA-stop
®
-M Brakes
Type 891. _ _ _ . _ Sizes 2 – 500
(B.8.1.GB)
16/11/2005 TK/KE/RJ
Chr. Mayr GmbH + Co. KG
Tel.: 08341 / 804-0
Eichenstraße 1
Fax: 08341 / 804-421
D-87665 Mauerstetten
http://www.mayr.de
Page 1 of 17
Germany
eMail:
info@mayr.de
Please read the Operational instructions carefully and follow them accordingly!
Ignoring these instructions may lead to malfunctions or brake failure, resulting in damage to other parts.
These installation and operational instructions (I+O) are part of your brake delivery.
Keep them handy and near to the brake at all times!
Contents:
Page 1: - Contents
- Manufacturer’s Declaration
- Safety and Guideline Signs
Page 2: - Safety Guidelines
Page 3: - Safety Guidelines
Page 4: - Brake illustrations
- Parts list
- Technical Data
Page 5: - Table 1: Technical Data (dependent on size)
- Table 2: Technical Data (dependent on size)
- Table 3: Technical Data (dependent on size)
Page 6: - Table 4: Technical Data (dependent on size)
- Table 5: Technical Data (dependent on size)
Page 7: - Table 6: Technical Data (dependent on size)
- Table 7: Technical Data (dependent on size)
- Table 8: Technical Data (dependent on size)
Page 8: - Torque-Time-Diagram
- Design
- Functions
- Delivery range / Delivery condition
Page 9:
- Installation Conditions
- Installation
Page 10: - Brake torque adjustment
- Brake inspection
- Installation hand release
Page 11: - Electrical connection for brake
- Building-up of magnetic field
Page 12: - Removal of magnetic field
Page 13: - Permitted friction work
- Friction power diagram for Types 891.01_._
and 891. 21_._
Page 14: - Friction power diagram for
Type 891.10_._
Page 15: - Maintenance
- Disposal
Page 16 - Operational malfunctions
Page 17 - Operational malfunctions
Manufacturer’s Declaration
In accordance with the machine regulations 98/37/EC, this product is a component built for machine or system installation. It is forbidden
to start use of the component until the machine or system into which it should be built is operating to EC standards.
The product corresponds with the low voltage regulations 73/23/EEC.
Continual compliance with the EMC regulations 89/336/EEC is the responsibility of the product user.
Safety and Warning Signs
Danger!
Danger of injury to personnel and
damage to the machine.
Warning!
Guidelines for important points.