background image

Electric Freestanding Range

Technical Information

 

November 2005 

16026688 

© 2005 Maytag Services 

AER5712BA* MER5751BA* MER5752BA*  MERH752BA* MERM752BA* 

  Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or 

repair of this unit. 

  Refer to Service Manual 16026784 for detailed installation, operating, testing, troubleshooting, and disassembly 

instructions. 

CAUTION

!

 

All safety information must be followed as provided in Service Manual 16026784. 

!

WARNING

 

To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless 
testing requires power. 

*Rating of 208 VAC is approximately 80% of 240 VAC value. 

 

Model AER5712BA* 

MER5751BA* 

MER5752BA* 

MERH752BA* 

MERM752BA* 

Power Source

 

 

 

 

 

Electrical rating, 240 V 

10.7 kW 

10.7 kW 

10.7 kW 

10.7 kW 

10.7 kW 

Electrical rating, 208 V 

8.1 kW 

8.1 kW 

8.1 kW 

8.1 kW 

8.1 kW 

Amperage 

40 Amp 

40 Amp 

40 Amp 

40 Amp 

40 Amp 

Frequency 

60 Hz 

60 Hz 

60 Hz 

60 Hz 

60 Hz 

Element Wattage @ 240 V

 

 

 

 

 

Ribbon 

element, 

dual 2,500* 2,500* 2,500* 2,500*  2,500* 

Ribbon element, 6 inch 

1,200*

 

1,200*

 

1,200*

 

1,200*

 

1,200*

 

Ribbon element, ceramas 

N/A 

N/A 

2,700* 

2,700* 

N/A 

Oven Wattage @ 240 V (208 V)

 

 

 

 

 

Bake 4 pass 

2,600  (1950) 

2,600  (1950) 

2,600 

(1950)  2,600 (1950)  2,600 (1950) 

Broil 4 pass 

3,000  (2250) 

3,000  (2250) 

3,000 

(2250)  3,000 (2250)  3,000 (2250) 

Oven Interior Dimensions  in. (cm)

 

 

 

 

 

Height 

16.5 (41.9)  16.5 (41.9)  16.5 

(41.9) 16.5 (41.9) 16.5 (41.9) 

Width 

23 (58.4) 23 (58.4) 23 (58.4) 

23 (58.4) 

23 (58.4) 

Depth 

18.125 (46) 

18.125 (46) 

18.125 (46) 

18.125 (46) 

18.125 (46) 

Product Exterior Dimensions  in. (cm)

 

 

 

 

 

Height 

overall 

46.75 (118.75) 46.75 (118.75) 46.75 (118.75) 46.75 (118.75)  46.75 (118.75) 

Width 

29.875 (75.9) 

29.875 (75.9) 

29.875 (75.9) 

29.875 (75.9) 

29.875 (75.9) 

Depth, excluding handle 

25 

(63.5) 

25 

(63.5) 

25 (63.5) 

25 (63.5) 25 (63.5) 

Features

 

 

 

 

 

Oven capacity (cubic feet) 

4.9 

4.9 

4.9 

4.9 

4.9 

Manual oven light 

Incandescent 

Incandescent 

Incandescent Incandescent  Incandescent 

Oven 

window 

Large Standard 

Large Large  Large 

Oven 

racks 

Yes Yes Yes Yes  Yes 

Timer 

Yes Yes Yes Yes  Yes 

Delay 

start 

Yes Yes Yes Yes  Yes 

Storage 

drawer 

Removable Removable Removable Removable  Removable 

Handle 

Standard Standard Standard Standard  Standard 

Weight lbs. (kg)

 

 

 

 

 

Crated 

166 (75.3)  166 (75.3)  166 (75.3) 166 (75.3) 166 (75.3) 

Summary of Contents for AER5712BA Series

Page 1: ...element dual 2 500 2 500 2 500 2 500 2 500 Ribbon element 6 inch 1 200 1 200 1 200 1 200 1 200 Ribbon element ceramas N A N A 2 700 2 700 N A Oven Wattage 240 V 208 V Bake 4 pass 2 600 1950 2 600 1950...

Page 2: ...20 6 to 22 6 240 VAC see wiring diagram for terminal identification If voltage is not present at bake element check wiring Broil element Disconnect wire leads to element and measure resistance of ter...

Page 3: ...ollowing for voltages at LO MED HI H1 to H2 Approximate Time On Time Off LO 6 94 MED 4 5 40 60 HI 100 0 240 VAC If not replace switch Ribbon element 2500W Disconnect wire leads to element and measure...

Page 4: ...play M1 Factory default Press and hold Cancel and Keep Warm pads for 3 to 5 seconds until beep sounds Allows the clock to be reset to factory settings M1 12 hour off Control automatically cancels cook...

Page 5: ...test the Quick Test mode will be disabled Display will indicate the following Key Operation Bake Bake relay activated DLB relay activated Broil Broil relay activated DLB relay activated Keep Warm DLB...

Page 6: ...state unknown neither locked or unlocked Always 1 minute Diagnostic Code Handling Code Measurable Displayed Action Taken By Control 1c1c Keypress Nothing Disables audible for key depression Disables k...

Page 7: ...ools 5 Special conditions for latch faults 9dxx A known good unlock position is defined as when the unlock switch reads closed and lock switch reads open A known good lock position is defined as when...

Page 8: ...nd Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to range before servicing unless testing requires power 16026688 8 November 2005 2005 Maytag Services C...

Page 9: ...and Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to range before servicing unless testing requires power November 2005 9 16026688 2005 Maytag Services...

Reviews: