MEC-Energijski sistemi, d.o.o.
Cesta na Okroglo 5,4202 Naklo, Slovenia/Europe
Tel: +386 (0) 59 280 800
Email: office@mec-europpe.com
mec-europe.com
Instruction Manual
Battery Chargers
ProTask-1200 Series:
Safety Rules and General Warnings
•
Persons, who are not able to use the charger in a safe way, because of their physical, sensory or mental incompetence, or because of their
lack of experience, should not use without the control or instruction from a skilled or qualified person.
•
The charger runs with 100-240 Volts alternating current, which is not suitable for children – Danger of Life. And beware of risk of electric shock
at all times.
•
Ensure sufficient air ventilation; do not cover the vent outlet while charging in progress.
•
Avoid flammable gases, solvents or vapours all the time. Prevent open flame or sparks while charging in progress. Explosion RISK!
•
The charger is exclusively designed for charging rechargeable batteries and must not be used for other purposes. Corresponding model should
be selected for particular lithium-based or lead-based batteries.
•
You should take into consideration of the charging instructions issued by the battery manufacturer before charging. Check also if the charge
profile fits your battery and application.
•
DO NOT OPEN or DISMANTLE the charger. Repair work must only be processed by authorized technical staff.
•
If the mains connection of the charger is damaged, it must be replaced with an original wire which is available at MEC or authorized dealers.
•
NEVER place the charger on top of the battery while charging in progress.
•
The charger should be protected against direct solar radiation or temperatures over 40°C.
•
In case of obvious damage or malfunctioning, disconnect the charger from the mains supply and protect against unintended reconnection.
•
The DC cable must not be cut, shortened or extended under any circumstances.
•
Keep the charger in dry room (rel. humidity <80%). Clean with dry cloth only. Avoid fluid of any kind to get into the charger.
Special Features
•
IP20 Load-dependent fan cooling; spray-painted metal housing
•
Microprocessor-based 4-Step charging technology with soft start and automatic re-start of the charge cycle
•
Battery
"
wake-up
"
function by sending out programmed
"
wake-up
"
pulses
•
Optimal and gentle charging for the greatest possiblity of charge cycles guaranteed with high frequent combinatorial circuit technology
•
5 Selectable battery types (GEL, AGM, WET, Calcium, +PS-Mode) and built-in battery temperature sensor for models targeting lead-based
batteries
•
LED indicators showing corresponding charge status and errors
•
Protection against short circuit, reverse polarity, over temperature or overload
Product Configuration
Models Targeting Lithium-based Batteries
1.
IR-Interface LEDs
2.
Red Mains LED
3.
Yellow Charge LED
4.
Green Full LED
5.
Red Error LED
6.
Mains Socket
7.
On / Off Switch
8.
Cooling Fan
IP20 Load-dependent fan-cooled. With one (1) or multiple,
selectable charge profiles, customized parameters.
CAN-bus / Ignition-Lock (optional).
2
3
4
5
NOVA-1200F
1
6
7
8