background image

 

USER MANUAL 

ME-650-VU/850-VU 
ME-1000-VU/2000-VU 

 

Thank you for purchasing this UPS. To safely operate this 
uninterruptible  power  supply  system,  please  read  and 
follow  all  instructions  carefully.  Please  read  this  manual 
thoroughly before attempting to unpack, install, or operate 
UPS, and keep this manual for further reference.   

 

IMPORTANT SAFETY INSTRUCTIONS 

  This UPS utilizes voltages that may be hazardous.  DO 

NOT attempt to disassemble the unit. The unit contains 
no  user  serviceable  parts.  Only  factory  service 
personnel may perform repairs.   

  Internal battery voltage is 12VDC. 

  Connection to any other type of receptacle other than a 

two-pole, three-wire grounded receptacle may result in 
shock hazard as well as violate local electrical codes. 

  In the event of an emergency, press the OFF button and 

disconnect the power cord from the AC power supply to 
properly disable the UPS. 

  DO NOT allow liquids or any foreign object to enter the 

UPS.  Do  not  place  beverages  or  any  other 
liquid-containing vessels on or near the unit.   

  This  unit  intended  for  installation  in  a  controlled 

environment  (temperature  controlled,  indoor  area  free 
of conductive contaminants). Avoid installing the UPS in 
locations  where  there  is  standing  or  running  water,  or   
excessive humidity. 

  DO NOT plug the UPS input into its own output. 

  DO NOT attach a power strip or surge suppressor to the 

UPS. 

  DO  NOT  attach  non-computer-related  items,  such  as 

medical  equipment,  life-support  equipment,  microwave 
ovens, or vacuum cleaners to UPS 

  To reduce the risk of overheating the UPS, do not cover 

the  UPS’ cooling  vents  and avoid exposing the unit to 
direct  sunlight  or  installing  the  unit  near  heat  emitting 
appliances such as space heaters or furnaces. 

  Unplug the UPS prior to cleaning and do not use liquid 

or spray detergent. 

  DO  NOT  dispose  of  batteries  in  a  fire  as  they  may 

explode. 

  DO  NOT  open  or  mutilate  the  battery  or  batteries. 

Released electrolyte is harmful to the skin and eyes. It 
may be toxic. 

  A battery can present a risk of electrical shock and high 

short  circuit  current.  The  following  precautions  should 
be observed when working on batteries: 

1) Remove  watches,  rings,  or  other  metal  objects  from 

the hands. 

2) Use tools with insulated handles. 
3) Wear rubber gloves and boots. 
4) DO NOT lay tools or metal parts on top of batteries. 
5) Disconnect  charging  source  prior  to  connecting  or 

disconnecting batteries terminals. 

  Servicing  of  batteries  should  be  performed  or 

supervised  by  personnel  knowledgeable  of  batteries 
and  the  required  precautions.    Keep  unauthorized 
personnel away from batteries. 

  When  replacing  batteries,  replace  with  the  same 

number and type of sealed lead-acid battery. 

  This  pluggable  type  A  equipment  with  battery  already 

installed by the supplier is operator installable and may 
be operated by laymen. 

  During  the  installation  of  this  equipment  it  should  be 

assured  that  the  sum  of  the  leakage  currents  of  the 
UPS and the connected loads does not exceed 3.5mA   

  Attention,  hazardous  through  electric  shock.  Also  with 

disconnection  of  this  unit  from  the  mains,  hazardous 
voltage  still  may  be  accessible  through  supply  from 
battery.  The  battery  supply  should  be  therefore 
disconnected  in  the  plus  and  minus  pole  at  the 
connectors of the battery when maintenance or service 
work inside the UPS is necessary. 

  The mains socket outlet that supplies the UPS shall be 

installed near the UPS and shall be easily accessibl

e.

 

 

PRODUCT OVERVIEW 

ME-650-VU/850-VU 
 

 

 

ME-1000-VU 

 

 

ME-2000-VU 

 

 

 

 

USB port 

Modem/phone 
surge 
protection 

Output 
receptacles 

Fault: red 
lighting 
Power switch 
AC mode: 
green lighting 
Batt. mode: 
yellow flashing 

AC input 

Batt. mode: 
yellow flashing 
Power switch 
AC mode: 
green lighting 
Fault: red 
lighting 

USB port 

Output 

receptacles 

AC input 

Modem/phone 
surge protection 

Power switch 

Fault: red lighting 

AC mode: 
green lighting 
Batt. mode: 
green flashing 

AC mode: indicating 

load level 

Batt. mode: indicating 

battery capacity 

AC input 

Output 
receptacles 

USB port 

Modem/phone 

surge protection 

Reviews: