background image

 

 

Mediflow Logyc Dry hand dryer 

 

 
 

Safety regulations 

 

 

All installation, maintenance and repair tasks must be carried out by qualified 
technicians. 

 

Mediclinics remembers the importance of: 

 

1. Becoming  familiar  with  the  equipment  and  carefully  reading  the  user  manual  prior  to 
operating.  

 

2. Disconnecting power prior to beginning any repair or maintenance action.  

 

3. Exercising care in accordance with the procedures included herein.  

 

 
 

General maintenance 

 
 

Preventive Maintenance - Cleaning 

 

Inspect the units 

annually or quarterly, 

depending on the dryer’s operating cycles.

 

 

Clean the active parts of the unit, such as: the motor, the heating element, the fan and 

the electronic circuit board with a soft brush. 

 

Maintain the air inlet and outlet free of dust and other obstructions; use a soft flat ended 

brush. 

 

Removal of the casing 

 

 
 

Consult the safety regulations prior to carrying out any work on the unit. 

 

Release the screws that attach the casing (2 units) using the supplied tamper-

proof screwdriver. 

Summary of Contents for Mediflow Logyc Dry

Page 1: ...h the procedures included herein General maintenance Preventive Maintenance Cleaning Inspect the units annually or quarterly depending on the dryer s operating cycles Clean the active parts of the unit such as the motor the heating element the fan and the electronic circuit board with a soft brush Maintain the air inlet and outlet free of dust and other obstructions use a soft flat ended brush Rem...

Page 2: ...e base by means of inner bolts Extract the lower part of the casing as shown in the image and lift it slightly to release the anchors To avoid scratching the casing place it on a flat surface with the visible part facing upward ...

Page 3: ...orporates a safety thermal limiter Maintenance The corrective maintenance of the motor consists of replacing the brushes The brushes have a theoretical useful life of 3 000 hours and must be replaced when their length is shorter than 5 mm Replacement of the brushes Press the clip that holds the brush ...

Page 4: ... the clip to one side to release the brush Remove the brush from its location and replace it Carry out the same procedure for the second motor brush Assemble by following the previous steps in reverse order ...

Page 5: ... greater safety we recommend you disconnect the three heating element cables that go to the three way terminal block of the electronic circuit board Use pliers to carefully extract the two circlips that secure the heating element ...

Page 6: ...Rotate the heating element a quarter turn clockwise until it is released from its anchors Carefully remove the heating element from its position ...

Page 7: ...of the motor that go to the two way terminal block located in the electronic circuit board Carefully remove the electronic circuit board from the guide located at the base by bending the clips that are located in the volute ...

Page 8: ...Release the screw attaching the volute to the base Remove the heating element ring located to the left of the fan ...

Page 9: ...Loosen the set screw that secures the fan to the drive shaft inserting an Allen key through the hole in one of the fan blades Remove the fan Release the two lateral springs that fasten the motor ...

Page 10: ...ics Band type coiled cable double heating element in Cr Al and Fe On MICA body Incorporates a thermal limiter Automatic disconnection 0 5 seconds before the motor stops Maintenance As preventive maintenance we recommend using a soft brush to remove dust and dirt on an annual or bi annual basis depending on the dryer s operating cycles ...

Page 11: ...the heating element Disconnect the three heating element cables that go to the three way terminal block of the electronic circuit board Use pliers to carefully extract the two circlips that secure the heating element ...

Page 12: ...he heating element a quarter turn clockwise until it is released from its anchors Remove the heating element from its housing in the volute and replace it Fit it by following the previous steps in reverse order ...

Page 13: ...e air outlet according to the room temperature Maintenance As preventive maintenance we recommend using a soft brush to remove dust and dirt on an annual or bi annual basis depending on the dryer s operating cycles It is also recommended to clean the LEDs regularly using a cloth dampened with alcohol to ensure the signal is emitted and received properly Replacement of the electronic circuit board ...

Page 14: ...e cables of the motor that go to the two way terminal block located in the electronic circuit board Carefully remove the electronic circuit board from the guide in the base by bending the clips located in the volute ...

Page 15: ...ase and replace it Fit it by following the previous steps in reverse order Insert the circuit board into the guide at an angle of 45º for it then to be positioned perpendicular to the base Replacement of the LED cables Remove the LED cables from their connection to the electronic circuit board ...

Page 16: ...Release the LED cables from the guide that secures them to the volute Remove the LEDs from their housing ...

Page 17: ...Setting the detection distance The detection distance can be set between 5 and 20 cm by means of the potentiometer located in the chassis of the LED cables ...

Reviews: