                   Meg 4.5  /  Sirius 450 

Fuel 

Wood (Beech) 

Mineral Fuel (Anthracite) 

Test Standard 

EN13229 

EN13229 

Test Cycle 

1.36kg over 0.83hrs 

0.9kg over 1hr 

Settings 

Primary 0%, 2nd 0% 

Primary 50%, 2nd 0% 

Flue Draft Pa (ins WG) 

12 (0.05) 

12 (0.05) 

Efficiency % 

81.0 

81.2 

Recommended Rating kW 

4.5 

4.5 

Mean Flue Gas Temp Rise °K  

248 

294 

Minimum air entry requirement 

2500 mm² 

2500 mm² 

Minimum clearance to combustibles 

150mm at sides, 400mm above  when fitted in masonry 

  

fireplace.    

Weight 

60  kg 

Flue outlet size 

125  mm 

Emissions as if O2 = 13% 

  

  

Nox mg/mᶟ 

105 

  

CO % 

0.2 

0.03 

CxHy mg/m² 

231 

  

Gas Flow g/sec 

4.1 

3.7 

Smoke emission mg/mᶟ 

89 

32 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Meg Solid Fuel Stoves Manual Version 2.2. Issued 29/04/2013 
Inset versions supplement 

Meg 4.5 Inset / Sirius 450 Inset 
Range of Inset Clean Burn Stoves 

 

 

This document is to be left with the householder after installation. 

All Meg stoves exceed the safety and performance requirements of European Standards. 
Independently tested by SGS (Notified Laboratory No: 0608) in 2010. 
Intermittent  burning  solid  fuel  roomheaters  for  installation  with  a  single  dedicated 
chimney.                                                

 

 

 

Read these instructions! Use only recommended fuels! 

This stove must be installed and commissioned by a fully qualified registered engineer, or the building inspector must be informed.  For more details contact your local 
authority. 
 
This document, when completed by  the installer, constitutes part of a ‘Hearth Notice’ for purposes of Building Law.  It must  be left with the  householder and placed 
where it can easily be found. 
 
Installed at Location: ....................................................................................................     By:........................................................................................................................ 
 
I  definitively  assert  that  this  installation  is  safe,  has  been  lit  and  demonstrated  to  the  householder,  conforms  with  current  building  regulations  and  with  these 
instructions. 
 
Signed:............................................................................................................................. Date:....................................................................................................................... 
 
Flue Draught measured on commissioning: ..................................................................... 
 
Fuel used on commissioning:........................................................................................... 
 

Installers; Please return the transit skids to the retailer so they can be returned to the manufacturer for re-use. 

 

 

The Clean Air Act 1993 and Smoke Control Areas 

 
Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed 
boiler if located in a designated smoke control area. It is also an offence to acquire an "unauthorised fuel" for use within a smoke control area unless it is used in an "exempt" appliance ("exempted" from the controls which 
generally apply in the smoke control area).  
The Secretary of State for Environment, Food and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas in England. In Scotland and Wales this power rests with 
Ministers in the devolved administrations for those countries. Separate legislation, the Clean Air (Northern Ireland) Order 1981, applies in Northern Ireland. Therefore it is a requirement that fuels burnt or obtained for use in 
smoke control areas have been "authorised" in Regulations and that appliances used to burn solid fuel in those areas (other than "authorised" fuels) have been exempted by an Order made and signed by the Secretary of State 
or Minister in the devolved administrations. 
Further information on the requirements of the Clean Air Act can be found here: http://smokecontrol.defra.gov.uk/  
Your  local  authority  is  responsible  for  implementing  the  Clean  Air  Act  1993  including  designation  and  supervision  of  smoke  control  areas  and  you  can  contact  them  for  details  of  Clean  Air  Act  requirements                                      
The Meg 4.5 / Sirius 450 stoves may be used in smoke control areas strictly in accordance with these instructions, when burning: 
UK: Untreated wood logs, natural anthracite or authorised smokeless fuels (authorised under s20(6) of the clean air act 1993) 
RoI: Wood logs, smokeless fuels or peat briquettes, but not petroleum coke (Control of Atmospheric Pollution Regulations 1970)  

 