background image

TECHNICAL REFERENCE

LANTIME

M300/MRS/AD10-AD10

16th February 2021

Meinberg Funkuhren GmbH & Co. KG

Summary of Contents for LANTIME M300/MRS/AD10-AD10

Page 1: ...TECHNICAL REFERENCE LANTIME M300 MRS AD10 AD10 16th February 2021 Meinberg Funkuhren GmbH Co KG...

Page 2: ......

Page 3: ...Reference Clock 21 6 3 COMx Timestring RS 232 22 6 4 Error Relay 23 6 5 Pulse Per Second Input 24 6 6 10 MHz Frequency Input 24 6 7 Time Code AM modulated Input 24 6 8 Time Code DCLS unmodulated Inpu...

Page 4: ...berg Funkuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Internet https www meinbergglobal com Mail info meinberg de Date 16 02 2021 LANTIME D...

Page 5: ...may only continue if you have understood and fulfilled all requirements In this documentation dangers and indications are classified and illustrated as follows DANGER The signal word indicates an imm...

Page 6: ...ko eines elektrischen Schlages Caution risk of electric shock IEC 60417 5041 Vorsicht hei e Oberfl che Caution hot surface IEC 60417 6056 Vorsicht Gef hrlich sich bewegende Teile Caution moving fan bl...

Page 7: ...e used for the purpose described in this manual In particular the given limits of the device must be observed The safety of the installation in which the unit is integrated is the responsibility of th...

Page 8: ...oiling additional measures e g Installation in an air conditioned control cabinet required Transport Unpacking Installation If the unit is brought into the operating room from a cold environment conde...

Page 9: ...rk properly and are undamaged Pay particular attention to the facts that the cables do not have kinks or that they are not too short around corners and no objects are placed on the cables Also make su...

Page 10: ...t the mains socket on the appliance or the mains socket of the house installation is freely accessible to the user so that the mains cable can be pulled out of the socket in case of emergency Outside...

Page 11: ...th conductor via the protective earth connection terminal If an external earth connection is provided on the housing it must be connected to the equipotential bonding rail grounding rail The mounting...

Page 12: ...stalled and when the doors are closed cooling fire protection shielding against electrical magnetic and electromagnetic fields Switch off in fault service case By switching off the devices are not dis...

Page 13: ...isks for the user and result in a loss of warranty as well as an exclusion of liability Danger due to moving parts keep away from moving parts Device parts can become very hot during operation Do not...

Page 14: ...struction Prepare removal and installation of assemblies Unload yourself for example by touching a grounded object before touching assemblies Ensure that you wear a grounding strap on the wrist when w...

Page 15: ...The product symbol on the left indicates that this electronic product must not be disposed of in domestic waste Return and Collection Systems For returning your old equipment please use the country s...

Page 16: ...receiver GNS UC only GPS and Galileo an IRIG time code receiver or a long wave receiver DCF77 MSF WWVB as well as external NTP servers or a DCF77 GNSS combination as hybrid receiver can be used as re...

Page 17: ...terial sheet steel Temperature range Operation 0 50 C 32 122 F Storage 20 70 C 4 158 F Relative humidity Operation max 85 non condensing at 30 C Maximum altitude Operation max 4000 m 13123 ft above se...

Page 18: ...h 445 mm 17 51 inch 304 mm 11 98 inch 288 mm 11 32 inch External Ground Connection on the Housing This connector must be wired to an equipotential bonding bar earthing bar Connection is possible on bo...

Page 19: ...In the top line of the display the operating mode of the reference clock reference time is shown Instead of GPS sync to GPS the messages GPS sync to OCX can appear In case the antenna connection is i...

Page 20: ...nection it is possible to configure the parameters with a terminal program To establish a connection between the LANTIME and a PC use a NULL MODEM cable Configure your terminal pro gram with 38400 Bau...

Page 21: ...6A N Power 2 7 8 6 6 1 AC DC Power Supply Hotplug In a redundant power supply operation it is possible to remove or install one of the power supply units e g in case of defect from the system housing...

Page 22: ...dissolved power supply can be removed with the handle C now 5 Put the new power supply in the free slot and secure it with the two previously dissolved Torx fastening screws A 6 Connect the 5 pin DFK...

Page 23: ...J h 170 61 BTU h N L AD10 PWR Power U 100V 240V N U 90V 265V max I 1 0A N f 50 60Hz N U 100V 200V N U 90V 250V max I 0 6A N 2 3 4 5 1 WARNING This equipment is operated at a hazardous voltage Danger t...

Page 24: ...le Output voltage 15 V 100 mA via antenna cable Connection type BNC female N standard female Cable type shielded coax Cable length max 300 m to RG58 max 700 m to RG213 Antenna GNSS IF 15 V BNC N Norm...

Page 25: ...drate framing 19200 8N1 default Timestring Meinberg Standard default Assignment Pin 2 RxD receive Pin 3 TxD transmit Pin 5 GND ground Connection type D SUB female 9pin Cable data cable shielded PC con...

Page 26: ...ng load max DC 30 W AC 60 VA Switching current UL CSA 0 46 A 140 V AC 0 46 A 65 V DC 1 A 30 V DC Response Time ca 2 ms Normal Operation Mode Normal Operation CO NO connected CO NO NC Error Mode Error...

Page 27: ...nput 10MHz frequency Signal level Sine wave 1 5 Vpp 5 Vpp or TTL Connection type BNC female Cable shielded coaxial line Freq In 6 7 Time Code AM modulated Input Signal output Unbalanced sine wave sign...

Page 28: ...BNC female isolated Cable shielded coax line TC DCLS In 6 9 Pulse Per Second Output Output signal PPS pulse per second Signal level TTL 2 5 V into 50 Ohm Pulse length 200 ms Connection type BNC femal...

Page 29: ...k Port IEEE 803 2 Signal 100BASE T Data transmission rate 10 100 Mbit s Connection type 8P8C RJ45 Cable Copper twisted pair e g CAT 5 0 Duplex Modes Half Full Autonegotiaton 100M 10M LAN x 26 Date 16t...

Page 30: ...d Selection of the Antenna location To receive enough satellites select a location that allows an unobstructed view of the sky otherwise there may be problems with the synchronization of the system Th...

Page 31: ...aused by lightning strikes can be transmitted via the antenna cable and may cause damage to the receiver The receiver is pro tected against these effects by using the MBG S PRO surge protection Being...

Page 32: ...le to the socket of the surge protection Earth cable to PE rail Cable circa 1 5 mm attached to the surge protection as short as possible 4 The next step is to connect the supplied coaxial cable betwee...

Page 33: ...nsate the signal propagation time of the antenna cable therefore you need to enter the length of the antenna cable in meters or the compensation time in nanoseconds into the settings of your receiver...

Page 34: ...8 Technical Appendix GPS Antenna Accessories 8 Technical Appendix GPS Antenna Accessories Physical Dimensions LANTIME Date 16th February 2021 31...

Page 35: ...h 9 MHz Frequencies Mixed frequency 10 MHz IF frequency 35 4 MHz Connector N Norm female connector Form factor ABS plastic case for outdoor installation Protection class IP66 Humidity 95 Temperature r...

Page 36: ...r values can be found in the data sheet of the cable used 8 2 Antenna Short Circuit Only for assembly groups with front display In case of an antenna line short circuit the following message appears i...

Page 37: ...ipped with two type N female connectors It has no dedicated input output polarity or prefered mounting orientation Phoenix CN UB 280DC BB Features High RF Performance Multiple Strike Capability 20 kA...

Page 38: ...WR in a 50 system typ 1 1 2 GHz Permissible HF power Pmax at VSWR xx 50 ohm system 700 W VSWR 1 1 200 W VSWR Capacity Core Earth typ 1 5 pF asymmetrical shield typ 1 5 pF Surge current resistance cond...

Page 39: ...8 3 1 MBG S PRO Physical Dimensions 67 11 15 8 25 13 4 8 3 2 Installation and Grounding 36 Date 16th February 2021 LANTIME...

Page 40: ...expansions GNSS GPS GLONASS Galileo BeiDou receiver IRIG time code receiver with DCLS or modulated Pulse Per Second Input PPS in up to 7 external NTP server PTP IEEE 1588 M400 M600 and M900 only Puls...

Page 41: ...displayed 1 GPS 20ns 2 PPS 30ns 2 NTP 30 000us 1 GPS is master 10ns 2 PPS in is available 20ns 3 IRIG no signal n a 4 NTP is available 30 000us 2 PTP IEEE1588 is available 300ns F1 MRS Input Prioritie...

Page 42: ...eiver The high precision orbit parameters of a satellite are called ephemeris parameters whereas a reduced pre cision subset of the ephemeris parameters is called a satellite s almanac While ephemeris...

Page 43: ...minated biphenyls PBBs and polybrominated diphenyl ethers PBDEs Bis 2 ethylhexyl phthalat DEHP Benzylbutylphthalat BBP Dibutylphthalat DBP Diisobutylphthalat DIBP above the legal threshold WEEE status...

Page 44: ...Normen und Richtlinien bereinstimmt to which this declaration relates is in conformity with the following standards and provisions of the directives RED Richtlinie ETSI EN 303 413 V1 1 1 2017 06 RED...