background image

 

948 TOURMALINE DRIVE, THOUSAND OAKS CALIFORNIA 91320 
Phone: (805) 497-2626,  Email: sales@meiseitools.com 

OPERATING INSTRUCTIONS 

To avoid physical injury and product damage, please read these operating instructions in their entirety before 
using 

Meisei’s 

HOT

WEEZERS

®

,  HOT

NIFE

™ 

or  Power  Supply  units.  Proper  use  ensures  optimum  performance, 

superior results and long product life. 

IMPORTANT: HOT

WEEZERS

® and HOT

NIFE

™ units should only be used in areas with proper ventilation.

 

POWER SUPPLY (M-10, M-20) 

Both the M-10 Power Supply (for Standard hand units) and the M-20 Power Supply (for ESD hand units) have a 
three-wire line cord and plug.  When plugged into a three-wire receptacle, the chassis is automatically grounded.  
The 

Power Supply’s 

front panels have an ON-OFF switch, pilot light, variable temperature control and either 

HI

 

and 

LO

 jacks (M-10) or a HI/LO switch (M-20).  

DO NOT use 

HI

 and 

LO

 jacks on the M-10 simultaneously. 

 

The output of each jack is an isolated low voltage AC for operator safety.   

TEMPERATURE SETTING 

As  the  composition  and  thickness  of  different  conductors,  materials  and  cables  varies,  new  users  should 
experiment with a sample of the material being stripped to find the ideal settings.  

At the ideal setting the stripper will be just hot enough to pierce the insulation without melting or burning, and 
the slug of stripped insulation should not stick to the stripper.   

The following are suggested starting points to determine the optimal temperature per material: 

LO

 Jack/Setting 

HI

 Jack/Setting 

PVC   

 

2.5 

Tefzel   

 

1.0 

Polyethylene   

4.0 

Silicone 

 

7.0 

Nylon   

 

5.0 

Teflon

®

 

 

8.0 

Kynar   

 

9.0 

 

If the insulation type is not known, start at 

1

 on the 

LO

 jack/setting and gradually increase the temperature 

until the desired result is achieved. 

Avoid temperature settings that generate fumes. Also, avoid using HOT

WEEZERS

® or HOT

NIFE

 

above 

9

 on the 

HI

 jack for prolonged periods as this will shorten the life of the stripper. 

STRIP LENGTH GAUGE (HOT

WEEZERS

® only) 

To avoid injury, always turn the Power Supply off and allow the HOT

WEEZERS

® to fully cool down before adjusting 

the strip length gauge. Hold the depth gauge by the red tip and adjust to the proper strip length. Never grasp 
the front stop plate as this may cause misalignment of the plate and damage to the HOT

WEEZERS

®.  If the gauge 

is not needed, fully retract it so that it does not interfere with operator performance  

STRIPPING THE WIRE (HOT

WEEZERS

® 

only) 

1)

 

Hold the HOT

WEEZERS

®

 

as you would a pencil (see diagram), with the tweezer blades pointing up. The rear 

face of the blades should be facing toward you as you align the conductor to be stripped with the correct 
gauge hole.