948 TOURMALINE DRIVE, THOUSAND OAKS CALIFORNIA 91320
Phone: (805) 497-2626, Email: sales@meiseitools.com
OPERATING INSTRUCTIONS
To avoid physical injury and product damage, please read these operating instructions in their entirety before
using
Meisei’s
HOT
WEEZERS
®
, HOT
NIFE
™
or Power Supply units. Proper use ensures optimum performance,
superior results and long product life.
IMPORTANT: HOT
WEEZERS
® and HOT
NIFE
™ units should only be used in areas with proper ventilation.
POWER SUPPLY (M-10, M-20)
Both the M-10 Power Supply (for Standard hand units) and the M-20 Power Supply (for ESD hand units) have a
three-wire line cord and plug. When plugged into a three-wire receptacle, the chassis is automatically grounded.
The
Power Supply’s
front panels have an ON-OFF switch, pilot light, variable temperature control and either
‘
HI
’
and
‘
LO
’
jacks (M-10) or a HI/LO switch (M-20).
DO NOT use
‘
HI
’
and
‘
LO
’
jacks on the M-10 simultaneously.
The output of each jack is an isolated low voltage AC for operator safety.
TEMPERATURE SETTING
As the composition and thickness of different conductors, materials and cables varies, new users should
experiment with a sample of the material being stripped to find the ideal settings.
At the ideal setting the stripper will be just hot enough to pierce the insulation without melting or burning, and
the slug of stripped insulation should not stick to the stripper.
The following are suggested starting points to determine the optimal temperature per material:
‘
LO
’
Jack/Setting
‘
HI
’
Jack/Setting
PVC
2.5
Tefzel
1.0
Polyethylene
4.0
Silicone
7.0
Nylon
5.0
Teflon
®
8.0
Kynar
9.0
If the insulation type is not known, start at
‘
1
’
on the
‘
LO
’
jack/setting and gradually increase the temperature
until the desired result is achieved.
Avoid temperature settings that generate fumes. Also, avoid using HOT
WEEZERS
® or HOT
NIFE
™
above
‘
9
’
on the
‘
HI
’
jack for prolonged periods as this will shorten the life of the stripper.
STRIP LENGTH GAUGE (HOT
WEEZERS
® only)
To avoid injury, always turn the Power Supply off and allow the HOT
WEEZERS
® to fully cool down before adjusting
the strip length gauge. Hold the depth gauge by the red tip and adjust to the proper strip length. Never grasp
the front stop plate as this may cause misalignment of the plate and damage to the HOT
WEEZERS
®. If the gauge
is not needed, fully retract it so that it does not interfere with operator performance
STRIPPING THE WIRE (HOT
WEEZERS
®
only)
1)
Hold the HOT
WEEZERS
®
as you would a pencil (see diagram), with the tweezer blades pointing up. The rear
face of the blades should be facing toward you as you align the conductor to be stripped with the correct
gauge hole.