Item ref: 600.100UK 

 

MTM01 

Digital Multimeter 

 

User Manual

Summary of Contents for 600.100UK

Page 1: ...Item ref 600 100UK MTM01 Digital Multimeter User Manual...

Page 2: ...age as marked on the tester between the terminals or between any terminal and grounding The rotary switch should be in the right position and no changeover of range shall be made while measurement is...

Page 3: ...ld be used to prevent the surface of the tester from corrosion or damage The tester is suitable for indoor use only Turn the tester power off when it is not in use and take out the battery when not us...

Page 4: ...600 100UK MTM01 User Manual LCD Power Button Range switch A mA terminal V terminal 10A terminal COM terminal HOLD Button Multi functionadapter...

Page 5: ...200mV 100uV 0 5 of rdg 3D 2V 1mV 20V 10mV 0 8 of rdg 5D 200V 100mV 600V 1V 1 0 of rdg 5D Input Impedance 10M Overload Protection 1000V DC or 750V AC rms Max Input voltage 1000V DC AC Voltage RANGE RES...

Page 6: ...urrent RANGE RESOLUTION ACCURACY 2mA 1uA 1 8 of rdg 2D 20mA 10uA 200mA 100uA 2 0 of rdg 2D 10A 10mA 2 0 of rdg 10D Overload Protection mA F0 5A 600V fuse 10A F10A 600V fuse Voltage Drop 200mV AC Curre...

Page 7: ...4D 20k 10 200k 100 2M 1k 20M 10k 1 0 of rdg 10D 200M 100k 5 rdg 10 10D Open Circuit Voltage about 3V Overload Protection 250V DC AC rms Capacitance RANGE RESOLUTION ACCURACY 2nF 1pF 4 0 of rdg 5D 20nF...

Page 8: ...ar on Digital Display along with the voltage polarity Please note In small range the meter may display an unstable reading when the test leads have not been connected to the load to be measured It is...

Page 9: ...e When the display shows the over range symbol 1 a higher range must be selected In addition 10A function is designed for intermittent use only RESISTANCE MEASUREMENT 1 Connect red lead to V black lea...

Page 10: ...ance The tested capacitor should be discharged before the testing procedure Never apply voltage to the input or serious damage may result CONTINUITY TEST 1 Connect the BLACK test lead to the COM jack...

Page 11: ...of the adaptor 4 LCD display will show the approximate hFE value BATTERY AND FUSE REPLACEMENT 1 Battery and fuse replacement should only be done after the test leads have been disconnected and power...

Page 12: ...nd black 9V PP3 battery EN61010 1 2010 This product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life T...