Page 1: ...34003641FR AA Page 1 T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R www mgeups com Installation and user manual Pulsar 700 1000 1500 1000 RT 1500 RT EXB 1000 1500 EXB 1000 1500 RT...

Page 2: ...34008097EN AB Page 2...

Page 3: ...cal and electronic waste Battery The product contains lead acid batteries that must be processed according to applicable local regulations concerning batteries The battery may be removed to comply wit...

Page 4: ...tion Pictograms Important instructions that must always be followed Information advice help Visual indication Action Audio signal In the illustrations on the following pages the symbols below are used...

Page 5: ...operation 13 2 7 UPS connection without a FlexPDU or HotSwap MBP module 14 3 Operation 3 1 Start up and normal operation 15 3 2 Operation on battery power 15 3 3 Return of AC power 16 3 4 UPS shutdown...

Page 6: ...242 x 158 x 400 Pulsar 1000 242 x 158 x 400 Pulsar 1000 RT 438 x 86 5 x 480 Pulsar 1500 242 x 158 x 450 Pulsar 1500 RT 438 x 86 5 x 480 Pulsar EXB 242 x 158 x 400 Pulsar EXB RT 440 x 86 5 x 480 Weigh...

Page 7: ...ctor for remote ON OFF and RPO Remote Power Off control 6 Connector for battery EXB module 7 Group of 3 programmable outlets for connection of equipment 8 Group of 3 outlets for connection of equipmen...

Page 8: ...y module 1 3 Control panel 20 Load protected LED 21 Downgraded operation LED 22 Load not protected LED 23 Alphanumeric display 24 Escape cancel button 25 Scroll button 26 Enter confirm button 27 ON OF...

Page 9: ...upports for the upright position RT model only 39 FlexPDU module optional 40 Connection cable between FlexPDU module and UPS 41 NMC communication card optional 42 HotSwap MBP module optional 43 Connec...

Page 10: ...llation of the RT model in a rack It is advised to install the battery EXB module s at the lowest position in the rack then install the UPS above Follow steps 1 to 4 for module mounting on the rails T...

Page 11: ...t operate simultaneously Tower model 1 Connect the RS232 33 or USB 34 communication cable to the serial or USB port on the computer equipment 2 Connect the other end of the communication cable 33 or 3...

Page 12: ...t the UPS cover back in place using the screws RT model 1 Connect the UPS socket 9 to the AC power source using the power cable from the equipments to be protected 2 Connect the input socket on the Fl...

Page 13: ...on the HotSwap MBP module using the cable 43 supplied This cable and the connectors are marked blue 3 Connect the UPS outlet 8 to the UPS Output 54 on the HotSwap MBP module using the cable 43 supplie...

Page 14: ...d 2 Connect the loads to the UPS using the cables 32 It is preferable to connect the priority loads to the 3 outlets marked 8 and the non priority loads to the 3 outlets marked 7 that can be programme...

Page 15: ...e used to read UPS measurements AC input voltage operating mode battery capacity and UPS serial number If UPS personalisation is desired it is advised to enter the personalisation mode at this time Th...

Page 16: ...Power Off allows a remote contact to be used to disconnect all the equipment connected to the UPS from the power supply Restarting the UPS requires manual intervention ROO Remote ON OFF allows remote...

Page 17: ...closed start up of UPS UPS connected to the network and network energized Note local On Off control via button 27 has priority over the remote control order Contact open shut down of UPS To return to...

Page 18: ...ll button 25 several times until the personalisation menu is reached Press the Enter button 26 to access the different possibilities Finally confirm the selection by pressing the Enter button 26 again...

Page 19: ...ery power Enabled Disabled Automatic restart Enabled Disabled The UPS restarts automatically when AC power returns Energy savings Disabled Enabled When function enabled battery shuts down when power d...

Page 20: ...evices Check the programmed overload level 6 LED 22 is ON the alphanumeric display indicates LOAD UNPROTECTED OUTPUT OVERLOAD The UPS is overloaded Devices connected to the UPS are fed directly by the...

Page 21: ...the wiring between the UPS and the HotSwap MBP module see section 2 6 13 The load is no longer supplied when the rotary switch 49 on the HotSwap MBP module is set to the Normal position The UPS is shu...

Page 22: ...attery two screws E Turn the connector F Pass the connector through the hole G Pull the plastic tab to remove the battery block and replace it Tower model A Put the front panel near the UPS B Disconne...

Page 23: ...g screws metal protection cover of the battery D Remove the metal protection cover of the battery E Pull the plastic tab to remove the battery block and replace it To ensure safety and high performanc...

Page 24: ...S control panel LED 51 UPS ON OK to switch goes OFF the UPS can now be disconnected and replaced Return to normal operation 1 Check that the UPS is correctly connected to the HotSwap MBP module 2 Star...

Page 25: ...re MGE UPS SYSTEMS 140 avenue Jean Kuntzmann Zirst Montbonnot St Martin 38334 St Ismier Cedex FRANCE Tel 33 0 4 76 18 34 14 Fax 33 0 4 76 18 45 21 training mgeups com www mgepowerlearning com Catalogu...

Page 26: ...nput power Voltage Frequency Power factor Single phase 100 120 140 V 160 V 184 V to 284 V 5 50 60 Hz autoselection 0 95 Load output Voltage Frequency Harmonic distortion THDV Overload capacity Current...

Page 27: ...he load Normal AC input The AC power line supplying the UPS under normal conditions Percent load Ratio of the power effectively drawn by the load to the maximum output of the UPS Personalisation It is...

Page 28: ...34008097EN AB MGE UPS SYSTEMS T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R 140 Avenue Jean Kuntzmann ZIRST Montbonnot St Martin 38334 Saint Ismier Cedex France www mgeups com...