background image

 

5103321100/AA

 - Page 1

Pulsar EXtreme

 

1500/2000 VA
2500/3000 VA

installation and user
manual

French

German

Italian

Spanish

Netherlands

Summary of Contents for Pulsar Extreme 1500 VA

Page 1: ...5103321100 AA Page 1 Pulsar EXtreme 1500 2000 VA 2500 3000 VA installation and user manual French German Italian Spanish Netherlands...

Page 2: ...at attention to the environmental impact of its products Measures that have made Pulsar EXtreme a reference in environmental protection include the eco design approach used in product development prod...

Page 3: ...to the AC power source via a wall outlet must remain in the immediate vicinity of the outlet The outlet must be easily accessible For UPSs connected to the AC power source via a terminal block a prote...

Page 4: ...primarily by consulting the contents the index Pictograms Important instructions that must always be followed Information advice help Visual indication Action Audio indication In the illustrations on...

Page 5: ...ower model 11 Rack model 11 2 2 Installation rack version 13 2 3 Connection to the RS 232 communications port optional 14 2 4 Installation of the communications card option 14 2 5 Securing and connect...

Page 6: ...p time 20 Sleep mode 20 Return of AC input power 20 3 5 Personalization 21 Function 21 ON OFF conditions tab 21 Battery tab 22 Output tab 22 By pass tab 22 ECO mode tab 23 3 6 Shutdown 23 4 Maintenanc...

Page 7: ...odel Rack model EXtreme 1500 to 3000 EXtreme 1500 to 2000 EXtreme 2500 to 3000 Dimensions in mm H x W x D 443 x 173 x 465 Weight in kg 29 36 EXtreme 1500 to 3000 EXtreme 1500 to 2000 EXtreme 2500 to 3...

Page 8: ...les socket for connection to AC power source outlets for direct connection to protected equipment manual bypass switch input terminal block with cable clamp output terminal block with cable clamp 1 Fa...

Page 9: ...age 9 1 Presentation 1 3 Back 8 7 6 8 11 10 9 6 10 11 9 slot for communications card option battery module connector battery circuit breaker rating plate connector for connection modules RS232 communi...

Page 10: ...fault battery fault ambient temp 40 C 15 16 17 hold down to display percent load 18 lamp test or buzzer OFF 19 operation on manual bypass 20 operation in ECO mode 21 operation in ON LINE mode 22 opera...

Page 11: ...tallation 2 1 Unpacking and checks RS 232 communications cable Solution Pac CD ROM UPS Driver diskette for UPS personalization documentation electrical power cord except INSTALL version 25 27 28 26 29...

Page 12: ...29 30 RS 232 communications cable Solution Pac CD ROM UPS Driver diskette for UPS personalization documentation electrical power cord except INSTALL version telescopic rails for mounting in 19 bay wit...

Page 13: ...5103321100 AA Page 13 2 2 Installation rack version 2 Installation Rack mounting diagram with rails The rails and the necessary mounting hardware are supplied with the UPS in the package 1 2 3 3 3 3 4...

Page 14: ...card 1 Remove the slot cover 2 Insert the card in the slot 3 Secure the card with the two screws 1 Connect the RS 232 communications cable to the serial port on the computer 2 Connect the RS 232 commu...

Page 15: ...al power cord to the socket for connection to AC power source 2 Connect the other end of the electrical power cord to an AC power outlet Fault tolerant 10 31 31 2 29 1 2 1 29 Securing the connection m...

Page 16: ...ugh the cable clamp 3 Connect the three wires to the output terminal block Always connect the earthing wire first 4 Remove the terminal block cover 5 Tighten the nut on the cable clamp The overall cab...

Page 17: ...equipment connections 1 Remove the terminal block cover 2 Insert the cable supplying the equipment and the power cable through the cable clamps 3 Connect the three wires of the equipment cable to the...

Page 18: ...this mode is that it reduces the consumption of electrical power The protected equipment is supplied directly by the AC power source as long as it remains within the tolerances set by the user ECO mo...

Page 19: ...o ON 2 Press the ON OFF button All connected equipment is energized The buzzer sounds LEDs and go ON If LEDs and do not go ON or if LEDs or flash there is a fault see section 4 1 3 3 Bargraph indicati...

Page 20: ...ittle remaining battery backup time Close all applications because UPS automatic shutdown is imminent End of backup time The buzzer sounds continuously Press button to turn the buzzer OFF The equipmen...

Page 21: ...y circuit breaker is closed UPS Driver installation 1 Insert the UPS Driver diskette in the drive of an IBM compatible microcomputer 2 Select the disk drive A 3 Double click upsdriv exe Once UPS Drive...

Page 22: ...tery shutdown warning threshold Charger Default setting Every day 20 remaining battery backup time Standard Options Once a week Once a month No test 40 remaining battery backup time CLA 2 4 or 8 hours...

Page 23: ...figure 3 Default setting Disabled not authorized 200 V to 240 V for 230 V rated voltage Options Enabled click to check The upper threshold max voltage is between the maximum authorized voltage for tr...

Page 24: ...buzzer beeps LED flashes Signification UPS overload Overload is too long or too high The UPS cuts the supply of power to the connected equipment and the buzzer sounds continuously The ambient temperat...

Page 25: ...d but directly from the AC power source via the automatic bypass LED ON the connected equipment is no longer supplied The equipment connected to the UPS is no longer protected A battery fault was dete...

Page 26: ...Open the battery circuit breaker s 3 Remove the two fixing screws and the connection module from the UPS Reconnection 1 Insert the connection module in the connector and secure using the two screws 2...

Page 27: ...nected equipment is supplied by the AC power source Reconnection 1 Insert the connection module in the connector and secure using the two screws 3 Close the battery circuit breaker s Check that UPS pe...

Page 28: ...s to recycle by certified companies and in compliance with all applicable regulations all UPS products recovered at the end of their service life contact your branch office Packing UPS packing materia...

Page 29: ...status CLA Long backup Module incorporating a charger for long backup times The charger is powerful time charger enough to charge battery extension modules offering very long backup times Cold start...

Page 30: ...er of the load to the manual bypass enables UPS maintenance or replacement without interrupting the supply of power to the connected equipment ON LINE mode The normal UPS operating mode by which the A...

Page 31: ...nications card 14 Connection modules 16 17 RS 232 communications port 14 E ECO mode 10 18 23 F Fault UPS Load 10 Transfer to automatic bypass 25 Fault tolerant 8 15 26 H Hot swap 8 16 27 I Install 8 1...

Page 32: ...321100 AA 5103321100 AB MGE UPS SYSTEMS N o t h i n g w i l l s t o p y o u n o w Publication MGE UPS SYSTEMS 09 99 140 Avenue Jean Kuntzmann ZIRST Montbonnot St Martin 38334 ST ISMIER CEDEX FRANCE ww...

Reviews: