scanCONTROL 3010 / 3012

Assembly Instructions

scan

CONTROL 

3010 / 3012

1. 

Warnings

Connect the power supply and the display-/output device according to the safety 
regulations for electrical equipment. The supply voltage must not exceed the specified 
limits.

 

> Risk of injury, damage to or destruction of the sensor

Avoid shocks and impacts to the sensor. Avoid constant exposure of the sensor to dust 
and splashes of water. Avoid exposure of sensor to aggressive materials (detergents, 
cooling emulsions).

 

> Damage to or destruction of the sensor

Read the detailed operating instructions before operating the sensor.  
These instructions are available online at 

www.micro-epsilon.com

.

2. 

Notes on CE Marking

The following apply to the scanCONTROL 30xx:  

 - EU Directive 2014/30/EU
 - EU Directive 2011/65/EU

The sensor is designed for use in industrial applications.  
The sensor fulfills the specifications of the EMC requirements, if the instructions in the 
operating instructions are followed.

3. 

Proper Environment

 - Protection class: 

IP67

 - Temperature range:

 

ƒ

Operation: 

0 ... +45 °C (+32 ... +113 °F), for free circulation of air

 

ƒ

Storage: 

-20 ... +70 °C ( -4 ... +158 °F)

 - Humidity: 

5 - 95 % (non-condensing)

Inhalt

1. 

Warnings 1

2. 

Notes on CE Marking  1

3. 

Proper Environment 

1

4. 

Laser Safety 

2

 

Laser Class 2M 2

 

Laser Class 3R 2

5. 

Connections, LED Displays 

3

 

Multifunction Port 

3

 

RS422, Synchronization 4

 

Trigger, Encoder, Mode Switching 

4

 

External Laser Switch-off, Optional 

4

 

LED Displays  5

6. 

Transmitting Measurement Results 

6

7. 

System Requirements   6

 

scanCONTROL Configuration Tools 

6

 

scanCONTROL 3D-View 6

8. 

Quick Start, Initial Operation, Software 

7

9. 

First Profile 

8

10. 

How to Access Profile Data 

8

11. 

scanCONTROL Gateway 

9

12. 

scanCONTROL 30xx with scanCONTROL Output Unit for Connecting to a PLC 10

 

Connecting the Supply Voltage  11

13. 

Unpacking, Included in Delivery  12

14. 

Additional Information  12

Summary of Contents for scanCONTROL 30 BL Series

Page 1: ...etergents cooling emulsions Damage to or destruction of the sensor Read the detailed operating instructions before operating the sensor These instructions are available online at www micro epsilon com...

Page 2: ...he sensor housing LASER RADIATION DO NOT STARE INTO BEAM OR EXPOSE USERS OF TELESCOPE OPTICS CLASS 2M LASER PRODUCT IEC 60825 1 2014 P 10 mW P 10 mW E 6 mW cm 0 P 658nm F 0 25kHz t 7 s LASER RADIATION...

Page 3: ...ns LED Displays 1 2 1 Multifunction port power supply I O 2 Ethernet port Multifunction Port Designation Sensor connector pin Cable color PCR3000 x Notes Ub 9 Red 11 V 30 V DC rated value 24 V max 5 W...

Page 4: ...ts of the multifunction port can either be used for encoder input trigger input or for load previously stored user modes The signal levels are switchable for all switching inputs between LLL TTL logic...

Page 5: ...is setting is activated by default and has priority over search the link local net The sensor scanCONTROL 30xx supports Power over Ethernet If the sensor is connected to a POE capable network adapter...

Page 6: ...us RTU protocol Measurement value transmission in ASCII format 7 System Requirements scanCONTROL Configuration Tools The following minimum system requirements are necessary Windows 7 Windows 8 or 8 1...

Page 7: ...Close unused connection plugs with the included protective caps Turn on the power supply 24 VDC Please wait until the scanCONTROL measuring system is recognized by the PC This may take a few seconds N...

Page 8: ...scanCONTROL and the PC On the left side you can adjust the settings for your measurement task the right side shows the profile data and information about the measurement 10 How to Access Profile Data...

Page 9: ...us systems Furthermore all scanCONTROL sensor settings can be set via the 2D 3D Gateway e g Laser on off or switch User Mode Sensor parameterization Power supply Triggering Encoder Synchronization Mod...

Page 10: ...ply OUT 24 V 0 V 0 V System supply In 24 V 0 V OU filter module 2 5 3 0 5 7 LINK ACT MS I O ETHERNET NS 8 7 6 5 4 3 2 1 N O LINK ACT 1 2 X 1 X 2 8 1 ON 24V X3 0V 0 WBM 255 DHCP OU fieldbus coupler L1...

Page 11: ...e Digital output terminals need a field supply of 5 VDC or 24 VDC depending on the module type After mounting the modules install the required wiring Connect the System supply out contacts of the OU F...

Page 12: ...ocumentation the Status and Error Messages and Notes sections in the scanCONTROL Configuration Tools operating instructions You will find details about the individual programs in the respective operat...

Reviews: