Warnings

Connect the power supply and the display-/output device according to the safety 

regulations for electrical equipment. The power supply must not exceed the specified 

limits.

 

> Risk of injury, damage to or destruction of the sensor
Avoid shocks and impacts to the sensor. Avoid continuous exposure to dust and 

spray on the sensor. Avoid exposure of sensor to aggressive materials (detergents, 

cooling emulsions).

 

> Damage to or destruction of the sensor
Read the detailed instruction manual before operating the sensor. You will find this 

manual on the provided CD or online at www.micro-epsilon.com.

2. 

Notes on CE Identification

The following applies to the scanCONTROL 30xx/BL:  

-  EU Directive 2014/30/EU

-  EU Directive 2011/65/EU, „RoHS“ category 9

The sensor is designed for use in industry and satisfies the requirements.

The sensor fulfills the specifications of the EMC requirements, if the instructions in the 

manual are followed.

3. 

Proper Environment

-  Protection class: 

IP 67

-  Operating temperature:  0 to +45 °C (+32 to +113 °F), by free circulation of air

-  Storage temperature: 

-20 to +70 °C ( -4 to +158 °F)

-  Humidity: 

5 - 95 % (non condensing)

4. 

Scope of Delivery of scanCONTROL 

30xx/BL

-  1 Sensor scanCONTROL 30xx/BL with integrated controller

-  1 Multifunction cable PCR2600/2900-5, length 5 m; for power supply, trigger and 

RS422; screw connector and free cable ends

-  Calibration final inspection / assembly instructions

-  2 protective caps

-  scanCONTROL Sofware-CD with drivers, programs and documentation

Assembly Instructions
scan

CONTROL 

3010/BL / 3060/BL

Summary of Contents for scanCONTROL 3010/BL

Page 1: ...canCONTROL 30xx BL EU Directive 2014 30 EU EU Directive 2011 65 EU RoHS category 9 The sensor is designed for use in industry and satisfies the requirements The sensor fulfills the specifications of t...

Page 2: ...XPOSE USERS OF TELESCOPE OPTICS CLASS 2M LASER PRODUCT IEC 60825 1 2014 P 10mW P 10mW E 6mW cm 0 P 405nm F 0 25kHz t 7 s COMPLIES WITH 21 CFR 1040 10 AND 1040 11 EXCEPT FOR CONFORMANCE WITH IEC 60825...

Page 3: ...hing input In4 GND In 7 black Ground connection In Screen Housing black Not electrically connected to GND 2 3 4 5 6 7 8 9 1 10 11 12 GND galvanically isolated from IN1 2 3 4 RS422 Laser on off Laser o...

Page 4: ...manual Chap 5 2 6 With standard sensors connecting the supply voltage activates the laser light source in the sensor Ethernet Connection Standard Connection to PC RJ45 connector 8 pin screw connector...

Page 5: ...esults scanCONTROL 30xx BL offers the following options for transmitting measurement results Ethernet interface Modbus TCP protocol UDP protocol Analog output of measurement values via optional Output...

Page 6: ...socket Connect the shield of the power supply cable to the PE protective earth conduc tor of the main power supply Close unused connection plugs with the provided protective caps Switch on the power...

Page 7: ...n scanCONTROL and PC On the left side you can adjust the settings for your measurement task the right side shows the profile data and information about the measurement 11 How to Access Profile Data Pr...

Page 8: ...V 0 V System supply In 24 V 0 V OU filter module 2 5 3 0 5 7 LINK ACT MS I O ETHERNET NS 8 7 6 5 4 3 2 1 N O LINK ACT 1 2 X 1 X 2 8 1 ON 24V X3 0V 0 WBM 255 DHCP OU fieldbus coupler L1 L2 L3 N PE OU...

Page 9: ...d supply in of the OU Filter module to the power supply 0 V and 24 V resp 0 V and 5 V i The system supply and field supply should be separated to ensure the bus operation and electrical isolation in c...

Page 10: ...s and Error Messages and Notes in the scanCONTROL Con figuration Tools manual You will find details to the separate programs in the respective instruction manuals or in the instruction manual of this...

Page 11: ......

Page 12: ...www micro epsilon com MICRO EPSILON Messtechnik GmbH Co KG K nigbacher Str 15 94496 Ortenburg Germany Tel 49 0 85 42 1 68 0 X9771399 02 A01 X9771399 02 A011069SWE...

Reviews: