Step 2 — Connect the System

Important:

 When connecting Ultra-Lock cordsets to the QX-870 

and QX-1, align the pins first and then push the connector into 
place. Do not twist the connectors, as this will bend the pins.

RS-232

1. Connect the Serial Communication Cable from “A” on the 

QX-870 to “2” on the QX-1. 

2. Connect the host cable from “1” on the QX-1 to the host computer.

3. Connect the photo sensor to “T” on the QX-1.
4. Connect the power supply to “3” on the QX-1.
5. Plug in the power supply.

Ethernet

1. Connect the Ethernet Cable from “B” on the QX-870 to the 

network.

2. Connect the power supply to “A” on the QX-870.
3. Plug in the power supply.

Standalone (with QX-1)

Standalone (without QX-1)

Step 1 — Check Hardware

Item

Description

Part Number

1

QX-870 Industrial Raster Scanner

FIS-0870-XXXXG

2

QX-1 Interface Device

98-000103-01

3

QX Cordset, Common, M12 12-pin Plug to M12 12-pin Socket, 1 m

61-000162-01

4

QX Cordset, Host, Serial, M12 12-pin Plug to DB9, 1 m

61-000152-01

5

QX Cordset, Host, Serial, M12 12-pin Socket to DB9, 1 m

61-000153-01

6

QX Power Supply, M12 12-pin Socket, 1.3 m

97-000003-01

7

QX Cordset, Host, Ethernet, M12 8-pin Plug to RJ45, 1 m

61-000160-01

8

QX Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m

99-000020-02

Note:

 Additional cordsets and accessories are available in the Microscan Product Pricing Catalog.

Caution:

 Be sure that all connections are secure 

BEFORE

 applying power 

to the system. Always power down 

BEFORE

 disconnecting any cables.

Hardware Required

Standalone (with QX-1)

Standalone (without QX-1)

Quick Start Guide

QX-870 Industrial 

Raster Scanner

P/N 83-110870 Rev A

Step 3 — Position Scanner

1. Place a test symbol in a location with as little ambient light as 

possible.

2. Position the scanner at the focal distance used in your application.
3. Align the test symbol with the scanner’s field of view.
4. Tip the scanner relative to the test symbol to avoid glare from 

specular reflection.

Pitch
axis

Bar code
label

Tilt
axis

axis

Scan line

Scanner

Pitch

Tilt

Skew

Symbol

Scanner

Maximum 
skew, tilt, 
and pitch: 
±30°

Step 4 — Install ESP

ESP Software can be found on the Microscan Tools CD that is 
packaged with the QX-870. 

1. Follow the prompts to install ESP from the CD.
2. Click on the ESP icon to run the program.

Note: 

ESP can also be installed from the 

Download Center

 at  

www.microscan.com

.

Refer to the 

QX-870 Industrial Raster Scanner User’s Manual

 for 

detailed information about using ESP to configure the QX-870.

Step 5 — Select Model

When you start ESP, the model menu will appear:

1. Click the button showing the QX-870.
2. Click 

OK

Note:

 You can also simply double-click the button showing 

your scanner to make your selection.

3.

Click 

Yes

 when this dialog appears:

Note:

 If you need to select another model later, click the 

Switch Model

 button near the top of the screen or use 

Model > New Model

 in the menu toolbar.

Reviews: