background image

V1.0

Earth1006

Operation Manual

Summary of Contents for Earth1006

Page 1: ...V1 0 Earth1006 Operation Manual...

Page 2: ...1 7 Key instruction 5 1 8 Interface 5 1 9 Application topology 6 1 10 Unpacking 7 1 11 Boot operation 7 2 Detailed parameters 8 2 1 Power supply 8 2 2 Display instruction 9 2 3 Network mode 11 2 4 In...

Page 3: ...2 Installation method dimension and instruction 29 4 2 1 Installation method 29 4 2 2 Installation instruction 29 4 2 3 Installation dimension 30 4 3 SIM card installation 30 4 4 Device battery replac...

Page 4: ...technology and craftwork s modification rights If the information were changed no more notice would be edited Please pay attention to the latest introduction Our company keeps the final power of inter...

Page 5: ...d realize the multi function including data collection storage alarming and transmission for underground water firefighting water dam water water supply and drainage pipeline With a wide coverage of w...

Page 6: ...wer alarm limit and web real time warning PC and mobile terminal data application Support customer self built system and configuration application Equipped with installation accessories Solution for u...

Page 7: ...440 minutes optional Upload information sensor data battery information network status self check information Data storage Local storage Flash 4MB more than 200 000 history data Configuration Configur...

Page 8: ...agnetic bar 1 fixed support 1 M5 bolt 1 8mm expansion bolt 3 200mm hoop 2 1 4 Outline dimension Unit mm 1 5 Panel structure Note 1 mounting hole 2 magnetic control key 3 display screen 4 fool proof in...

Page 9: ...y induces 1s and the screen is not lit key induces 8s the device boot Boot state the key induces 1s the screen lit When the screen is bright the key induces 1s flip When the screen is bright the key i...

Page 10: ...ion accuracy 0 5 FS Input current 30mA Low level 0V 1V DC High level 5V 12V DC Pulse frequency 10Hz Support max 3 way sensor parameter analysis and also be used for device configuration RS485 1 9 Appl...

Page 11: ...pc After unpacking please check carefully according to above list The specific quantity shall be consistent with the customer order contract If there is damage loss shortage or discrepancies of access...

Page 12: ...city See description on label Nameplate 20Ah 12V 12VDC 110V 240V AC 50 60Hz 20 Ah 12V Solar Panel 12V 20W Battery Lifetime 3 5 years Related to transmission frequency Longer than 1 month Relat ed to t...

Page 13: ...al tower icon only SIM card Card status No card unrecognized card Configuration Configuration mode When the configuration icon is lit it enters the configuration mode and the device stops the data tra...

Page 14: ...Green 85 3 Green Bars 75 2 Green Bars 65 1 Green Bar 65 Empty 12V DC 110V 240V AC Adapter Icon displayed on web Battery shows full on the displayer Rechargeable Battery Solar power 95 Full Green 85 3...

Page 15: ...the upper limit of channel threshold below the lower limit of channel threshold 2 3 Network mode Table 2 3 network mode Communicati on mode Zone Standard Frequency bands 2G Global bands GSM 850 900 1...

Page 16: ...B3 B5 B8 Japan FDD LTE B1 B3 B8 B18 B19 B26 NB IoT Global bands B1 B3 B8 B5 B20 B28 LoRa 433 470 868 Europe 915 USA MHz transmission distance 5km According to site environment 2 4 Interface definition...

Page 17: ...NS Recharg eable battery s olar power 12 VDC 1 VCC Supply solar panel Non rechargea ble Battery has no power interface 2 GND Supply solar panel 110V 24 0V AC 50 60Hz 1 L AC L Please pay attention to c...

Page 18: ...wn in table 2 5 Table 2 5 AI interface Interfac e type Terminal type Pin Definiti on Details Note AI 5PINS 5 AGND Common port feed 100mA 1 Vo feed 2 AI1 Analog input 1 0V 5V DC 4mA 20mA DC Input curre...

Page 19: ...which can connect with three different sensors But the AI interfaces are standard alone interfaces cannot be extended by using the external junction box Different types of sensor channels can be disti...

Page 20: ...l value is 1 When the MST071 shift switch is raised well cover change it turns on and outputs the high level PI The channel value is 0 Note If the device has only one 4 PIN terminal it can only connec...

Page 21: ...NS 2 GND Common port feed 100mA 1 Vo feed 3 RS485 A RS485 A Support max 3 way sensor parameter analysis and also suitable for device configuration support MPM47xx protocol ModBus RTU protocol of Micro...

Page 22: ...sary DB9 female connector definition Pin Wire color definition details 1 brown RS485 A RS485 A 2 blue RS485 B RS485 B 5 black GND Common port 6 grey 3 3V 12V Power input Note The interface configurati...

Page 23: ...on Details Note Camera 9PINS 2 GND Common port feed 500mA 1 Vo feed 3 RS485 A RS485 A Specialized for camera 4 RS485 B RS485 B Electrical connection 3 Device configurations 3 1 configuration tool Each...

Page 24: ...DB9 configuration cable Users need to purchase the USB RS485 serial line Z TEK ZE628 is recommended by themselves Please note when the RS485 interface is used in the Configuration Mode Pin 6 needs to...

Page 25: ...hod can be seen in the Help page of big data platform 3 4 Configuration options Table 3 1 configuration options Items Configurati on item Configuration selection Configuration operation Configurat ion...

Page 26: ...5535 Under special circumstances the device supports SMS configuration SMS configuration commands are as follows send SMS to the center number 1064837639832 PZYM 115 29 194 124 PZDK 8080 1064837639832...

Page 27: ...fault 30 Transmissi on interval 1 5 10 30 60 360 720 1440 mins Collection interval transmission interval 24 collection interval default 30 Photograp h interval 30 60 720 1440 mins Default 1440 AI inte...

Page 28: ...to modify Pressure MPa Temperature Temperature F Level cm Level m Humidity RH Flow cm Flow m Flow rate cm h Flow rate m h pm2 5 ug m null Display accuracy 1 2 3 decimal places The screen displays the...

Page 29: ...decimal places Sensor physical properties it is not recommended to modify Power on delay 1 1000 50ms default 40 Image alarm Y N Default N calibration Zero calibration Span calibration RS485 interfa c...

Page 30: ...RTU Slave address 01 99 Default 01 Function code 03 04 Default 04 Initial address 01 99 Default 01 Register qty 01 99 Default 04 Byte order 3210 2301 1032 0123 Default 3210 Collection type Same with...

Page 31: ...gnal input DI PI Null Local configurati on Trig mode high low level Default high level Alarm level high low level Only DI valid Default high level resolution Only PI valid 32 bits Float keep 3 decimal...

Page 32: ...curacy Application configuration Lower threshold lower limit of range upper threshold Default 20 FS Remote configurati on Upper threshold upper limit of range lower threshold Default 80 FS others Devi...

Page 33: ...ation method dimension and instruction 4 2 1 Installation method Wall mounting and hoop mounting type 4 2 2 Installation instruction The installation of the Earth1006 remote monitoring terminal is sho...

Page 34: ...n dimension Wall mounting type 112mm 70mm shown in figure 4 3 Hoop mounting type 70mm 180mm stud diameter Unit mm M5 R4 110 9 2 80 R4 9 8 Figure 4 3 backboard dimension 4 3 SIM card installation Step...

Page 35: ...ication PCB Tap the yellow key of SIM card holder in communication PCB popping up the card slop and then install the SIM card After installation please plug the FPC wire back to the socket Attention B...

Page 36: ...e replaced periodically When you find the battery voltage from the data platform is lower than 13V or the local battery is null or there is no report for several days it is possible that the battery p...

Page 37: ...eplace the used battery connector from the control PCB socket with a new one and stick the strip Step 4 connect the FPC flat wire to control PCB socket of top cover Step 5 install top cover Tighten th...

Page 38: ...34 Level Covers abnormal Pressure Flow...

Page 39: ...ation dimension Attention please do not use heavy hammer to strike the wall like brick wall cement brick and red brick wall It is suggested to use light percussion drill which will make the hole size...

Page 40: ...nd it is ready for operation Attention for a reliable wireless transmission it is suggested to install the terminal within 50cm from the wellhead 4 5 3 hoop mounting type Required accessories 1pc wall...

Page 41: ...less steel hoop 1pc M5 bolt 1pc solar panel Customer self purchased Step 1 Fix the solar panel on stud by solar panel fixing bracket the bracket is provided by the customer the size of the solar panel...

Page 42: ...etails please check Help page from iot microsensor cn 6 FAQ There will be some possible questions during application and the solutions are shown in table 6 1 Table 6 1 failure analysis and troubleshoo...

Page 43: ...ng SIM card or replace battery please ensure the FPC connection is reliable Low battery Check battery voltage and replace the battery 3 Parameters setting unavailable No response after the RS485 seria...

Page 44: ...configuration of parameter setting software APN not configured Check with the local SIM card provider if the APN service is available if it is available configure on the device SIM card error Check i...

Page 45: ...er Check remote address information to ensure a correct configuration 5 Others Please contact manufacturer for other special failure 7 Responsibility Within one year from the delivery date we shall re...

Page 46: ......

Reviews: